Schneider Electric ATV650D15N4EU, EAN: 3606480906817

Schneider Electric ATV650D15N4EU frequency converter 15 kW 3x380-480 V

Industrial Material > Automation > Frequency converter, soft starter

Schneider Electric ATV650D15N4EU frequency converter 15 kW 3x380-480 V

Lieske Part No. 1866428
Mfg Part No ATV650D15N4EU
EAN-Code 3606480906817
Manufacturer Schneider Electric
Here only 3.149,25 EUR
3.747,61 EUR incl. VAT

Further information for Schneider Electric ATV650D15N4EU frequency converter 15 kW 3x380-480 V

Additional features
Number of discrete inputs8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V)
Discrete input logic16 preset speeds
Number of discrete outputs0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA
Number of analog inputs3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: -10 - 10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Number of analogue outputs2
Analog output typeSoftware-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AQ1, AQ2: 0 - 20 mA, resolution 10 bit; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA
Relay output number3
Relay output typeConfigurable relay logic R2: sequence relay no electrical life 100000 cycles; configurable relay logic R3: sequence relay no electrical life 100000 cycles; configurable relay logic R1: fault relay normally open/normally closed contact electrical life 100000 cycles
Max. switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Min. switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Number of power phases3 phases
Physical interfaceEthernet; 2-wire RS 485
Access methodSlave Modbus TCP
Transmission speed10, 100 Mbits; 4,800, 9,600, 19,200 BpS, 38.4 Kbit/s
Transmission frameRTU
Output voltage= supply voltage
Permissible temporary current increase1.5 x In for 60 s (heavy-duty operation); 1.1 x In for 60 s (normal operation)
Data format8 bits, configurable to odd, even or no parity
Polarisation typeNo impedance
Frequency resolutionAnalogue input: 0.012/50 Hz; Display unit: 0.1 Hz
Electrical connectionCable side: screw terminal 10 - 16 mm²; motor: screw terminal 10 - 16 mm²; control: removable screw terminals 0,5 - 1,5 mm²
Connection typeRJ45 (at decentralized graphical terminal) for Modbus, serial; RJ45 (at decentralized graphical terminal) for Ethernet/Modbus TCP
Swap modeHalf-duplex, full-duplex, auto-negotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus, serial
SupplyInternal power supply for setpoint potentiometer (1 to 10 kOhm): 10.5 V DC +/-5 %
Local signalling3 LEDs (dual-colour) for status of integrated communication; 4 LEDs (dual-colour) for communication module status; 1 LED (red) for presence of voltage; 3 LEDs for local diagnostics
Input compatibilityDI5, DI6: Discrete input Level 1 PLC corresponds to IEC 65A-68; STOA, STOB: Discrete input Level 1 PLC corresponds to IEC 61131-2; DI1...DI6: Discrete input Level 1 PLC corresponds to IEC 61131-2
Sampling duration5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analogue input; 10 ms +/- 1 ms (AO1) - analogue output; 2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy+/-1 % AO1, AO2 with temperature variation of 60 °C analog output; +/- 0.6 % AI1, AI2, AI3 with temperature variation of 60 °C analog input
Linearity errorAO1, AO2: +/- 0.2 % for analog output; AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Update timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Insulationbetween power and control terminals
Housing mountingWall mounting
4-quadrant operation possibleFalse
Control profile for asynchronous motorsConstant standard torque; Optimized torque mode; Variable standard torque
Control profile for synchronous motorsSynchronous reluctance motor; permanent magnet motor
Max. output frequency500 kHz
Acceleration and deceleration rampsLinearly adjustable from 0.01 - 9999 s
Motor slip compensationAdjustable; Deactivatable; Not available in permanent magnet motor control; Automatic, independent of load
Clock frequency4 - 12 kHz with power reduction factor; 2 - 12 kHz adjustable
Rated switching frequency4 kHz
Braking to standstillBy direct current injection
Integrated brake chopperFalse
Max. input current27,0 A
Max. output voltage480,0 V
Apparent power15 kVA at 480 V (heavy-duty operation); 19.4 kVA at 480 V (normal operation)
Max. peak current35.3 A for 60 s (heavy-duty operation); 34.9 A for 60 s (normal operation)
Network frequency50 - 60 Hz
Potential line Isc50 kA
Base load current at high overload23,5 A
Base load current at low overload31,7 A
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With safety function Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)Correct
with safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Quantity per set1
Width264 mm
Height678 mm
Depth330 mm
Product weight19,6 kg
Contractual warranty
Warranty (in months)18
Main features
Product seriesAltivar Process ATV600
Product-specific applicationProcesses and auxiliary equipment
Product or component typeVariable speed drive
VariantWith load isolator switch
Device short nameATV650
Mounting modeSurface mounting
Communications protocolEthernet; Modbus TCP
[UH,nom] Rated operating voltage380 - 480 V -15 - +10 %
Relative symmetric net voltage tolerance10 %
Relative symmetric net frequency tolerance5 %
Rated output current31,7 A
Degree of protection (IP)IP55
Product applicationAsynchronous motors; synchronous motors
EMC filterIntegrated with 50 m corresponds to IEC 61800-3 category C2; Integrated with 150 m corresponds to IEC 61800-3 category C3
Degree of protectionUL Type 12 corresponds to UL 508C
Cooling typeforced convection
Supply frequency50 - 60 Hz -5 - 5 %
Motor power (kW)11 kW (heavy-duty operation); 15 kW (normal operation)
Motor power (HP)15 hp heavy-duty operation; 20 hp normal operation
Mains power23.3 A at 480 V (normal operation); 20.6 A at 380 V (heavy-duty operation); 18.1 A at 480 V (heavy-duty operation); 27 A at 380 V (normal operation)
Continuous output current23.5 A at 4 kHz for heavy-duty operation; 31.7 A at 4 kHz for normal operation
Output frequency of speed controller0,1…500 Hz
Safety functionSTO (Safe Torque Off) safely switched-off torque SIL 3
Mounting
Insulation resistance> 1 MOhm 500 V DC for 1 minute to ground
Noise level53.7 dB, corresponds to 86/188/EEC
Pollution degree2 corresponds to IEC 61800-5-1
Vibration resistance1 Gn (f= 13…200 Hz) according to IEC 60068-2-6; 1.5 mm peak to peak (f= 2…13 Hz) according to IEC 60068-2-6
Shock resistance15 Gn for 11 ms corresponds to IEC 60068-2-27
Relative humidity5…95 % condensation not permitted corresponds to IEC 60068-2-3
Operating ambient temperature40…50 °C (with derating factor); -15…40 °C (without power reduction)
Operating altitude1000 - 4800 m with current reduction 1 % per 100 m; = 1,000 m without power reduction
Operating positionVertical +/- 10 degrees
Product certificationsCSA; TÜV; ATEX INERIS; UL; ATEX Zone 2/22
TextCE
StandardsIEC 61800-3 Environment 1 Category C2; EN/IEC 61800-3 Environment 2 Category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1; IEC 61800-3
Electromagnetic compatibilityTesting of immunity against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs immunity test Level 3 according to IEC 61000-4-5; Conducted HF immunity test Level 3 according to IEC 61000-4-6; Immunity test against electrostatic discharge Level 3 according to IEC 61000-4-2
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock (during operation)150 m/s² at 11 ms
Max. acceleration under vibration load (during operation)10 m/s² at 13 - 200 Hz
Max. deflection under vibration load (during operation)1.5 mm at 2 - 13 Hz
Permissible relative humidity (during operation)Class 3K5 according to EN 60721-3
Over voltage categoryIII
Control loopAdjustable PID controller
Ambient air temperature during transport-40…70 °C
Ambient temperature during storage-40…70 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height55,0 cm
VPE 1 width39,2 cm
VPE 1 length80,0 cm
Packaging weight (Lbs)25,0 kg
Frequency converter ATV650 - 15kW/20HP - 380/480V- IP55/UL type12 - disc.switch.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1866428
qrcode für Schneider Electric ATV650D15N4EU frequency converter 15 kW 3x380-480 V