| Additional features |
| Number of discrete inputs | 8 |
| Discrete input type | DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V) |
| Discrete input logic | 16 preset speeds |
| Number of discrete outputs | 0 |
| Discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA |
| Number of analog inputs | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: -10 - 10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
| Number of analogue outputs | 2 |
| Analog output type | Software-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AQ1, AQ2: 0 - 20 mA, resolution 10 bit; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R2: sequence relay no electrical life 100000 cycles; configurable relay logic R3: sequence relay no electrical life 100000 cycles; configurable relay logic R1: fault relay normally open/normally closed contact electrical life 100000 cycles |
| Max. switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC |
| Min. switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Number of power phases | 3 phases |
| Physical interface | Ethernet; 2-wire RS 485 |
| Access method | Slave Modbus TCP |
| Transmission speed | 10, 100 Mbits; 4,800, 9,600, 19,200 BpS, 38.4 Kbit/s |
| Transmission frame | RTU |
| Output voltage | = supply voltage |
| Permissible temporary current increase | 1.5 x In for 60 s (heavy-duty operation); 1.1 x In for 60 s (normal operation) |
| Data format | 8 bits, configurable to odd, even or no parity |
| Polarisation type | No impedance |
| Frequency resolution | Analogue input: 0.012/50 Hz; Display unit: 0.1 Hz |
| Electrical connection | Cable side: screw terminal 10 - 16 mm²; motor: screw terminal 10 - 16 mm²; control: removable screw terminals 0,5 - 1,5 mm² |
| Connection type | RJ45 (at decentralized graphical terminal) for Modbus, serial; RJ45 (at decentralized graphical terminal) for Ethernet/Modbus TCP |
| Swap mode | Half-duplex, full-duplex, auto-negotiation Ethernet/Modbus TCP |
| Number of addresses | 1…247 for Modbus, serial |
| Supply | Internal power supply for setpoint potentiometer (1 to 10 kOhm): 10.5 V DC +/-5 % |
| Local signalling | 3 LEDs (dual-colour) for status of integrated communication; 4 LEDs (dual-colour) for communication module status; 1 LED (red) for presence of voltage; 3 LEDs for local diagnostics |
| Input compatibility | DI5, DI6: Discrete input Level 1 PLC corresponds to IEC 65A-68; STOA, STOB: Discrete input Level 1 PLC corresponds to IEC 61131-2; DI1...DI6: Discrete input Level 1 PLC corresponds to IEC 61131-2 |
| Sampling duration | 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analogue input; 10 ms +/- 1 ms (AO1) - analogue output; 2 ms +/- 0.5 ms (DI1...DI4) - discrete input |
| Accuracy | +/-1 % AO1, AO2 with temperature variation of 60 °C analog output; +/- 0.6 % AI1, AI2, AI3 with temperature variation of 60 °C analog input |
| Linearity error | AO1, AO2: +/- 0.2 % for analog output; AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input |
| Update time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Insulation | between power and control terminals |
| Housing mounting | Wall mounting |
| 4-quadrant operation possible | False |
| Control profile for asynchronous motors | Constant standard torque; Optimized torque mode; Variable standard torque |
| Control profile for synchronous motors | Synchronous reluctance motor; permanent magnet motor |
| Max. output frequency | 500 kHz |
| Acceleration and deceleration ramps | Linearly adjustable from 0.01 - 9999 s |
| Motor slip compensation | Adjustable; Deactivatable; Not available in permanent magnet motor control; Automatic, independent of load |
| Clock frequency | 4 - 12 kHz with power reduction factor; 2 - 12 kHz adjustable |
| Rated switching frequency | 4 kHz |
| Braking to standstill | By direct current injection |
| Integrated brake chopper | False |
| Max. input current | 27,0 A |
| Max. output voltage | 480,0 V |
| Apparent power | 15 kVA at 480 V (heavy-duty operation); 19.4 kVA at 480 V (normal operation) |
| Max. peak current | 35.3 A for 60 s (heavy-duty operation); 34.9 A for 60 s (normal operation) |
| Network frequency | 50 - 60 Hz |
| Potential line Isc | 50 kA |
| Base load current at high overload | 23,5 A |
| Base load current at low overload | 31,7 A |
| With safety function Safely Limited Speed (SLS) | False |
| With safety function Safe brake management (SBC/SBT) | False |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | False |
| With safety function Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | Correct |
| with safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Quantity per set | 1 |
| Width | 264 mm |
| Height | 678 mm |
| Depth | 330 mm |
| Product weight | 19,6 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | Altivar Process ATV600 |
| Product-specific application | Processes and auxiliary equipment |
| Product or component type | Variable speed drive |
| Variant | With load isolator switch |
| Device short name | ATV650 |
| Mounting mode | Surface mounting |
| Communications protocol | Ethernet; Modbus TCP |
| [UH,nom] Rated operating voltage | 380 - 480 V -15 - +10 % |
| Relative symmetric net voltage tolerance | 10 % |
| Relative symmetric net frequency tolerance | 5 % |
| Rated output current | 31,7 A |
| Degree of protection (IP) | IP55 |
| Product application | Asynchronous motors; synchronous motors |
| EMC filter | Integrated with 50 m corresponds to IEC 61800-3 category C2; Integrated with 150 m corresponds to IEC 61800-3 category C3 |
| Degree of protection | UL Type 12 corresponds to UL 508C |
| Cooling type | forced convection |
| Supply frequency | 50 - 60 Hz -5 - 5 % |
| Motor power (kW) | 11 kW (heavy-duty operation); 15 kW (normal operation) |
| Motor power (HP) | 15 hp heavy-duty operation; 20 hp normal operation |
| Mains power | 23.3 A at 480 V (normal operation); 20.6 A at 380 V (heavy-duty operation); 18.1 A at 480 V (heavy-duty operation); 27 A at 380 V (normal operation) |
| Continuous output current | 23.5 A at 4 kHz for heavy-duty operation; 31.7 A at 4 kHz for normal operation |
| Output frequency of speed controller | 0,1…500 Hz |
| Safety function | STO (Safe Torque Off) safely switched-off torque SIL 3 |
| Mounting |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to ground |
| Noise level | 53.7 dB, corresponds to 86/188/EEC |
| Pollution degree | 2 corresponds to IEC 61800-5-1 |
| Vibration resistance | 1 Gn (f= 13…200 Hz) according to IEC 60068-2-6; 1.5 mm peak to peak (f= 2…13 Hz) according to IEC 60068-2-6 |
| Shock resistance | 15 Gn for 11 ms corresponds to IEC 60068-2-27 |
| Relative humidity | 5…95 % condensation not permitted corresponds to IEC 60068-2-3 |
| Operating ambient temperature | 40…50 °C (with derating factor); -15…40 °C (without power reduction) |
| Operating altitude | 1000 - 4800 m with current reduction 1 % per 100 m; = 1,000 m without power reduction |
| Operating position | Vertical +/- 10 degrees |
| Product certifications | CSA; TÜV; ATEX INERIS; UL; ATEX Zone 2/22 |
| Text | CE |
| Standards | IEC 61800-3 Environment 1 Category C2; EN/IEC 61800-3 Environment 2 Category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1; IEC 61800-3 |
| Electromagnetic compatibility | Testing of immunity against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs immunity test Level 3 according to IEC 61000-4-5; Conducted HF immunity test Level 3 according to IEC 61000-4-6; Immunity test against electrostatic discharge Level 3 according to IEC 61000-4-2 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock (during operation) | 150 m/s² at 11 ms |
| Max. acceleration under vibration load (during operation) | 10 m/s² at 13 - 200 Hz |
| Max. deflection under vibration load (during operation) | 1.5 mm at 2 - 13 Hz |
| Permissible relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Over voltage category | III |
| Control loop | Adjustable PID controller |
| Ambient air temperature during transport | -40…70 °C |
| Ambient temperature during storage | -40…70 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 55,0 cm |
| VPE 1 width | 39,2 cm |
| VPE 1 length | 80,0 cm |
| Packaging weight (Lbs) | 25,0 kg |
Frequency converter ATV650 - 15kW/20HP - 380/480V- IP55/UL type12 - disc.switch.