Schneider Electric ATV630D75N4, EAN: 3606480701450

Schneider Electric ATV630D75N4 frequency converter 380–480 V IP21

Industrial Material > Automation > Frequency converter, soft starter

Schneider Electric ATV630D75N4 frequency converter 380–480 V IP21

Lieske Part No. 694826
Mfg Part No ATV630D75N4
EAN-Code 3606480701450
Manufacturer Schneider Electric
Here only 7.454,65 EUR
8.871,03 EUR incl. VAT

Further information for Schneider Electric ATV630D75N4 frequency converter 380–480 V IP21

Complementary
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (
Discrete input logic16 preset speeds
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Network number of phases3 phases
Physical interfaceEthernet; 2-wire RS 485
Method of accessSlave Modbus TCP
Transmission rate10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frameRTU
Permissible temporary current boost1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty)
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Frequency resolutionDisplay unit: 0.1 Hz; Analog input: 0.012/50 Hz
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/20 AWG...16 AWG; Motor: screw terminal 95...120 mm²/3/0 AWG...250 kcmil; Line side: screw terminal 95...120 mm²/3/0 AWG...250 kcmil
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP; RJ45 (on the remote graphic terminal) for Modbus serial
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
SupplyExternal supply for digital inputs: 24 V DC (19…30 V)
Local signalling3 LEDs for local diagnostic; 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage
Input compatibilityDI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Sampling duration2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AO1, AO2: +/- 0.2 % for analog output
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
IsolationBetween power and control terminals
Power range55…100 kW at 380…440 V 3 phases; 55…100 kW at 480…500 V 3 phases
Enclosure mountingWall mounted
4 quadrant operation possibleFalse
Asynchronous motor control profileConstant torque standard; Optimized torque mode; Variable torque standard
Synchronous motor control profilePermanent magnet motor; Synchronous reluctance motor
Maximum output frequency500 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAdjustable; Can be suppressed; Not available in permanent magnet motor law; Automatic whatever the load
Switching frequency2.5...8 kHz with derating factor; 2...8 kHz adjustable
Nominal switching frequency2.5 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Maximum input current131.3 A
Maximum output voltage480.0 V
Apparent power93.7 kVA at 480 V (normal duty); 72.2 kVA at 480 V (heavy duty)
Maximum transient current159.5 A during 60 s (normal duty); 159 A during 60 s (heavy duty)
Network frequency50...60 Hz
Prospective line Isc50 kA
Base load current at high overload106.0 A
Base load current at low overload145.0 A
Power dissipation in WNatural convection: 174 W at 380 V, switching frequency 2.5 kHz; Forced convection: 1369 W at 380 V, switching frequency 2.5 kHz
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive
Quantity per set1
Width290 mm
Height922 mm
Depth323 mm
Net weight58 kg
Contractual warranty
Warranty (in months)18
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level62.4 dB conforming to 86/188/EEC
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating); 50…60 °C (with derating factor)
Operating positionVertical +/- 10 degree
Product certificationsCSA; ATEX zone 2/22; TÜV; ATEX INERIS; UL; DNV-GL
MarkingCE
StandardsUL 508C; IEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air295 m3/h
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Ambient air transport temperature-40…70 °C
Ambient air temperature for storage-40…70 °C
Logistical informations
Country of originIN
Main
Range of productAltivar Process ATV600
Product specific applicationProcess and utilities
Product or component typeVariable speed drive
VariantStandard version
Device short nameATV630
Mounting modeWall mount
Communication port protocolEthernet; Modbus serial; Modbus TCP
[Us] rated supply voltage380...480 V - 15...10 %
Relative symmetric mains voltage tolerance10 %
Relative symmetric network frequency tolerance5 %
nominal output current145.0 A
IP degree of protectionIP21
Product destinationAsynchronous motors; Synchronous motors
EMC filterIntegrated with 150 m conforming to IEC 61800-3 category C3
Degree of protectionUL type 1 conforming to UL 508C
Type of coolingForced convection
Supply frequency50...60 Hz - 5...5 %
Motor power kW75 kW (normal duty); 55 kW (heavy duty)
Motor power hp100 hp normal duty; 75 hp heavy duty
Line current131.3 A at 380 V (normal duty); 112.7 A at 480 V (normal duty); 98.9 A at 380 V (heavy duty); 86.9 A at 480 V (heavy duty)
Continuous output current145 A at 2.5 kHz for normal duty; 106 A at 2.5 kHz for heavy duty
Speed drive output frequency0.1…500 Hz
Safety functionSTO (safe torque off) SIL 3
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height47.000 cm
Package 1 Width45.000 cm
Package 1 Length115.000 cm
Package 1 Weight74.000 kg
Altivar 600 Prozess Frequenzumrichter - Umrichter zum Betrieb und Schutz von Pumpen. Frequenzumrichter ATV630, 100 HP, 380-480V, IP21. Abmessungen 290 x 922 x 323 mm, Leistung KW 75 kW. Ausgangsfrequenz 0,1-500 Hz. Überlast im Normalbetrieb 110% für 60s, Überlast im Modus hohe Überlast 150% für 60s (bei Deklassierung um eine Leistungsklasse). Steuerungstypen Asynchronmotoren, konstantes Drehmoment, variables Drehmoment, optimierter Drehmomentmodus, Synchronmotor PM, (Permanentmagnet) Motor. Integrierte Sicherheitsfunktion STO (Sichere Anlaufsperre (Safe Torque Off)) SIL3. Anzahl der integrierten E/A Analoge Eingänge 3. Analoge Ausgänge 2. Digital Eingänge 8. Relaisausgänge 3. Integrierte Kommunikation Modbus/TCP, serielle Modbus-Schnittstelle. Konfigurations- und Bedienelemente Dezentrales grafisches Bedienterminal, integrierter Web-Server, DTM (Device Type Manager), SoMove-Software. Optional E/A-Erweiterungskarten, Relaisausgangskarten. Optionale Kommunikationskarten, (EtherNet/IP und Modbus/TCP mit zwei Ports, CANopen Daisy Chain RJ45, Sub-D und Schraubklemmen, ProfiNet, Profibus DP V1 und DeviceNet).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/694826
qrcode für Schneider Electric ATV630D75N4 frequency converter 380–480 V IP21