| Complementary |
| Apparent power | 23.2 kVA at 380 V |
| Continuous output current | 30.5 A at 380 V; 30.5 A at 460 V |
| Maximum transient current | 33.6 A for 60 s |
| Speed drive output frequency | 0.5…200 Hz |
| Speed range | 1…10 |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Local signalling | 1 LED (red) for DC bus energized |
| Isolation | Electrical between power and control |
| Type of cable | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / 14 AWG; L1/R, L2/S, L3/T: terminal 10 mm² / 6 AWG; U/T1, V/T2, W/T3: terminal 16 mm² / 4 AWG |
| Tightening torque | 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES); 1.7 N.m, 15 lb.in (L1/R, L2/S, L3/T); 3 N.m, 26.5 lb.in (U/T1, V/T2, W/T3) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 % |
| Sampling duration | 2 ms +/- 0.5 ms F discrete; 2 ms +/- 0.5 ms R discrete; 2 ms +/- 0.5 ms RES discrete; 3.5 ms +/- 0.5 ms VIA analog; 22 ms +/- 0.5 ms VIB analog |
| Response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s); FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s); FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s); RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
| Accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C; +/- 0.6 % (VIB) for a temperature variation 60 °C; +/- 1 % (FM) for a temperature variation 60 °C |
| Linearity error | VIA: +/- 0.15 % of maximum value for input; VIB: +/- 0.15 % of maximum value for input; FM: +/- 0.2 % for output |
| Analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits; FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
| Discrete output type | Configurable relay logic: (FLA, FLC) NO - 100000 cycles; Configurable relay logic: (FLB, FLC) NC - 100000 cycles; Configurable relay logic: (RY, RC) NO - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
| Discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm; R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm; RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
| Discrete input logic | Positive logic (source) (F, R, RES), = 11 V (state 1); Negative logic (sink) (F, R, RES), >= 16 V (state 0) |
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.024/50 Hz |
| Communication service | Read holding registers (03) 2 words maximum; Monitoring inhibitable; Write single register (06); Time out setting from 0.1 to 100 s; Read device identification (43); Write multiple registers (16) 2 words maximum |
| Option card | Communication card for LonWorks |
| Specific application | HVAC |
| Discrete output number | 2 |
| Analogue input number | 2 |
| Analogue input type | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits; VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits; VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm; VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Physical interface | 2-wire RS 485 |
| Connector type | 1 RJ45; 1 open style |
| Transmission rate | 9600 bps or 19200 bps |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, 1 stop, odd even or no configurable parity |
| Type of polarization | No impedance |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points; Voltage/frequency ratio - Energy Saving, quadratic U/f; Voltage/frequency ratio, 2 points; Flux vector control without sensor, standard; Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) |
| Torque accuracy | +/- 15 % |
| Transient overtorque | 120 % of nominal motor torque +/- 10 % for 60 s |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 3200 s; Automatic based on the load |
| Motor slip compensation | Not available in voltage/frequency ratio motor control; Automatic whatever the load; Adjustable |
| Switching frequency | 6...16 kHz adjustable; 12...16 kHz with derating factor |
| Nominal switching frequency | 12 kHz |
| Braking to standstill | By DC injection |
| Network frequency | 47.5...63 Hz |
| Prospective line Isc | 22 kA |
| Protection type | Overheating protection: drive; Thermal power stage: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply overvoltage and undervoltage: drive; Line supply undervoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; With PTC probes: motor |
| Width | 290 mm |
| Height | 560 mm |
| Depth | 315 mm |
| Net weight | 36.5 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Environmental characteristic | Classes 3C1 conforming to IEC 60721-3-3; Classes 3S2 conforming to IEC 60721-3-3 |
| Noise level | 57.4 dB conforming to 86/188/EEC |
| Operating altitude | 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m; |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating); 40…50 °C (with derating factor) |
| Operating position | Vertical +/- 10 degree |
| Product certifications | NOM 117; C-Tick; CSA; UL |
| Marking | CE |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Regulation loop | Adjustable PI regulator |
| Ambient air temperature for storage | -25…70 °C |
| Logistical informations |
| Country of origin | CN |
| Main |
| Device short name | ATV212 |
| Product destination | Asynchronous motors |
| Network number of phases | 3 phases |
| Motor power kW | 15 kW |
| Motor power hp | 20 hp |
| Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Line current | 22.8 A at 480 V; 28.4 A at 380 V |
| Range of product | Altivar 212 |
| Product or component type | Variable speed drive |
| Product specific application | Pumps and fans in HVAC |
| Communication port protocol | BACnet; METASYS N2; LonWorks; APOGEE FLN; Modbus |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| EMC filter | Class C1 EMC filter integrated |
| IP degree of protection | IP55 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 39.000 cm |
| Package 1 Width | 40.000 cm |
| Package 1 Length | 80.000 cm |
| Package 1 Weight | 31.500 kg |
Focus on centralized technical management - Immediate overview of energy consumption. Fault detection and timely intervention options: drive belt breakage, pump running dry, phase failure, power failure, etc. Preventive maintenance to minimize costs and optimize the system: fault notifications, operating times, etc. Connection to building management systems via embedded protocols. Focus on user-friendliness - Tools for installation, configuration and monitoring of the system (decentralized graphic terminal in 6 languages, multi-loader, Bluetooth and SoMove Mobile). Compact design. Easy maintenance. Focus on protection functions - Guaranteed continuous operation. Permanently integrated building functions (fire protection mode, register monitoring, mechanical protection function, etc.). Integrated EMC filters, harmonic protection technology (THDI ~ 30%).