Schneider Electric ATS490C41Y, EAN: 3606486948897

Schneider Electric ATS490C41Y soft starter 410A 208-690V

Schneider Electric ATS490C41Y soft starter 410A 208-690V

Lieske Part No. 803841
Mfg Part No ATS490C41Y
EAN-Code 3606486948897
Manufacturer Schneider Electric
Here only 4.403,93 EUR
5.240,68 EUR incl. VAT

Further information for Schneider Electric ATS490C41Y soft starter 410A 208-690V

Complementary
Device connectionIn the motor supply line; Inside delta
Overload current profile400 % Ie for 13 s
On-load factor50 %
Operating cycles/hour10 cyc/h
[Us] control circuit voltage110...230 V AC 50...60 Hz - 15...10 %
Apparent power90 VA
Integrated motor overload protectionTrue
motor thermal protection classClass 10E
Protection typePhase failure: mains; Thermal protection: starter; Thermal protection: motor; Current overload: motor; Motor underload: motor; Excessive acceleration time: motor; Motor phase loss detection: motor; Protection against line phase inversion: mains; External thermal protection: motor; Protection delta inside wiring: starter; Short-circuit between motor phase and earth: motor
current limiting %In (5 x Ie maximum)150…700 %
Rated current pwr loss specification410 A
Power loss static current independent19 W
Power loss per device current dependent99 W
Power loss during starting5480 W during starting at 40 °C at 400% Ie
StandardsEN/IEC 60947-4-2; UL 60947-4-2; IEC 60664-1
Product certificationsCE; cULus; UKCA; RCM; CCC; DNV; ATEX; EAC; KC
MarkingCE; CULus; UKCA; RCM; CCC; ATEX; EAC; KC
[Uc] control circuit voltage24 V DC
Discrete input number5
Discrete input type(DI1) digital input, 4.4 kOhm; (DI2) digital input, 4.4 kOhm; (DI3) digital input, 4.4 kOhm; (DI4) digital input, 4.4 kOhm; (STO) digital input, > 1 kOhm
Input compatibilityDI1: discrete input level 1 PLC conforming to EN/IEC 61131-2; DI2: discrete input level 1 PLC conforming to EN/IEC 61131-2; DI3: discrete input level 1 PLC conforming to EN/IEC 61131-2; DI4: discrete input level 1 PLC conforming to EN/IEC 61131-2; STO: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logicDigital input DI1 at State 0: 0...< 5 V and 11 V, >= 5 mA; Digital input DI2 at State 0: 0...< 5 V and 11 V, >= 5 mA; Digital input DI3 at State 0: 0...< 5 V and 11 V, >= 5 mA; Digital input DI4 at State 0: 0...< 5 V and 11 V, >= 5 mA; Digital input STO at State 0: 0...< 5 V and 11 V, >= 5 mA
Relay output number3
Relay output typeRelay outputs R1A, R1C NO; Relay outputs R2A, R2C NO; Relay outputs R3A, R3C NO
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1; Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
Discrete output number2
Discrete output typeProgrammable digital output DQ1
Output compatibilityOpen collector level 1 PLC conforming to IEC 65A-68
Analogue input number1
Analogue input typeAI1/PTC1 : PTC/PT 100/PT 1000/KTY84 temperature probe; PTC2 : PTC/PT 100/PT 1000/KTY84 temperature probe; PTC3 : PTC/PT 100/PT 1000/KTY84 temperature probe
Analogue output number1
Analogue output typeCurrent output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm; Voltage output AQ1 : 0...10 V , impedance> 470 Ohm
Connector type1 RJ45 for connecting Modbus serial; 1 RJ45 for connecting Modbus TCP/EtherNet/IP
Physical interface2-wire RS 485; 100-BASE-TX category 5 or industrial Ethernet
Transmission frameRTU; TCP/UDP
Transmission rate4.8…38.4 kbps; 100 BASE TX
Data format8 bits, configurable odd, even or no parity 1or 2 stop
Number of addresses0…247 for Modbus serial
Method of accessSlave Modbus serial
Type of polarizationNo impedance for Modbus serial
Display screen availableTrue
Operating positionVertical +/- 10 degree
Height455 mm
Width304 mm
Depth300 mm
Net weight19 kg
internal bypassTrue
Function availablePre-heating; Smoke extraction; Second motor set; Deceleration with torque control; Braking; Boost; Line contactor control; Reverse contactor control; Anti-jam; Jog; Borehole pump starting; Condition monitoring; Power monitoring; Cybersecure firmware update
material declarationTrue
Contractual warranty
Warranty (in months)18
Environment
Pollution degreeLevel 3
[Uimp] rated impulse withstand voltage6 kV
[Ui] rated insulation voltage690 V
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Ambient air temperature for operation-25…40 °C (without derating); 40…60 °C (with current derating of 1 % per °C above 40 °C)
Ambient air temperature for storage-40…70 °C
Ambient air transport temperature-40…70 °C
Operating altitude2000...4800 m with current derating 1 % per 100 m above 2000 m
Relative humidity5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage)1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2...9 Hz
Maximum acceleration under vibrational stress (during operation)1 gn at 13…200 Hz
Maximum acceleration under vibratory load (during storage)1 gn at 9…200 Hz; 1.5 gn at 200…500 Hz
Maximum acceleration under vibratory load (during transport)1 gn at 9…200 Hz; 1.5 gn at 200…500 Hz
Maximum acceleration under shock impact (during operation)15 gn at 11 ms
Maximum acceleration under shock load (during storage)10 gn at 11 ms
Maximum acceleration under shock load (during transport)10 gn at 11 ms
Logistical informations
Country of originID
Main
Range of productAltivar Soft Starter ATS490
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationProcess and infrastructures
Device short nameATS490
Network number of phases3 phases
Utilisation categoryAC-3A; AC-53A
Ue power supply voltage208...690 V AC (- 15...10 %)
power supply frequency50...60 Hz - 20...20 %
[Ie] rated operational currentNormal duty: 410 A in line (at
Service factor at Ie100
rated current in heavy duty320 A at 40 °C for heavy duty
Torque controlTrue
IP degree of protectionIP00
Motor power hp125 hp at 208 V normal duty; 150 hp at 230 V normal duty; 300 hp at 460 V normal duty; 350 hp at 575 V normal duty; 100 hp at 208 V heavy duty; 125 hp at 230 V heavy duty; 250 hp at 460 V heavy duty; 300 hp at 575 V heavy duty
With safety function Safe torque off (STO)True
Safe Torque Off (STO)STO (safe torque off): SIL 1 conforming to IEC 61508; STO (safe torque off): PL c/category 2 conforming to ISO 13849
Cybersecurity functionsTrue
Cybersecurity level and standardSecurity level (SL) 1 conforming to IEC 62443-4-2
Communication port protocolModbus serial; Modbus TCP/EtherNet/IP
Option cardCommunication module for CANopen daisy chain; Communication module for CANopen Sub-D; Communication module for CANopen open style; Communication module for Profibus DP V1; Communication module for PROFINET
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height47.500 cm
Package 1 Width26.000 cm
Package 1 Length58.000 cm
Package 1 Weight25.000 kg
Unit Type of Package 2P06
Number of Units in Package 23
Package 2 Height61.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight83.000 kg
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/803841
qrcode für Schneider Electric ATS490C41Y soft starter 410A 208-690V