| Complementary |
| Apparent power | 1.2 kVA at 240 V |
| Power dissipation in W | 30 W |
| Discrete input number | 7 |
| Discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhm; DI1...DI6 logic inputs, 24 V DC (30 V); DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
| Discrete input logic | Positive logic (source); Negative logic (sink) |
| Discrete output number | 1 |
| Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA; Open collector DQ- 0…1 kHz 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits; AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits; AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits; Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Relay output number | 2 |
| Relay output type | Configurable relay logic R1A 1 NO electrical durability 100000 cycles; Configurable relay logic R1B 1 NC electrical durability 100000 cycles; Configurable relay logic R1C; Configurable relay logic R2A 1 NO electrical durability 100000 cycles; Configurable relay logic R2C |
| Maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
| Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector type | RJ45 |
| Method of access | Server Modbus serial; Subordinate BACnet MS/TP |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps; 9.6, 19.2, 38.4, 76.8 kbit/s |
| Transmission frame | RTU; MS/TP |
| Number of addresses | 0…247; 0…127 |
| Data format | 8 bits, configurable odd, even or no parity 1or 2 stop |
| Type of polarization | No impedance |
| Line current | 5.9 A at 200 V; 4.9 A at 240 V |
| Prospective line Isc | 1 kA |
| Output frequency | 0.599 kHz |
| Switching frequency | 2...16 kHz adjustable; 4...16 kHz with derating |
| nominal switching frequency | 4 kHz |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points; Flux vector control with sensor, standard; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor - Energy Saving; Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor |
| Acceleration and deceleration ramps | Linear; U; S; CUS; Ramp switching; Acceleration/deceleration ramp adaptation; Acceleration/deceleration automatic stop with DC injection |
| Motor slip compensation | Automatic whatever the load; Adjustable 0...300 %; Not available in voltage/frequency ratio (2 or 5 points) |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Standards | IEC 61800-5-1; IEC 61800-3; UL 508C; IEC 61800-3 environments 1 category C2; IEC 61800-3 environments 2 category C3; IEC 60721-3; IEC 61508; IEC 13849-1 |
| Product certifications | CULus; CE; UKCA; KC; EAC; ATEX; RCM |
| Marking | CULus; CE; UKCA; KC; EAC; ATEX; RCM |
| With safety function Safe torque off (STO) | True |
| Protection type | Line supply phase loss: drive; Motor phase loss: motor; Line supply overvoltage and undervoltage: drive; Overheating protection: drive; Overload: motor; With PTC probes: motor; Short-circuit between motor phases: drive; Overcurrent between output phases and earth: drive |
| Width | 72 mm |
| Height | 143 mm |
| Depth | 128 mm |
| Net weight | 1.0 kg |
| Function available | Fire mode; Run permissive; PID controller; Additional PID; Damper control; Underload detection for broken belt |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Pollution degree | 2 |
| Operating position | Vertical +/- 10 degree |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Relative humidity | 5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
| Overvoltage category | III |
| Ambient air transport temperature | -25…70 °C |
| Ambient air temperature for operation | -10…50 °C without derating; 50…60 °C with derating factor |
| Ambient air temperature for storage | -25…70 °C |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Altivar HVAC ATH200 |
| Product specific application | HVAC |
| Product or component type | Variable speed drive |
| Variant | Standard version |
| Device short name | ATH230 |
| Product destination | Asynchronous motors; Synchronous motors |
| Mounting mode | Cabinet mount |
| IP degree of protection | IP20 |
| Network number of phases | 1 phase |
| [Us] rated supply voltage | 200...240 V - 15...10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Supply frequency | 50...60 Hz - 5...5 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 3.3 A |
| Maximum transient current | 3.7 A |
| Motor power kW | 0.37 kW |
| Motor power hp | 0.5 hp |
| Safety function | STO (safe torque off) |
| Safety level | SIL 3 conforming to IEC 61508; PL = e conforming to ISO 13849-1 |
| EMC filter | Class C2 EMC filter integrated |
| Communication port protocol | Modbus serial; BACnet MS/TP |
| Option card | Communication module for BACnet IP |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.500 cm |
| Package 1 Width | 18.500 cm |
| Package 1 Length | 19.500 cm |
| Package 1 Weight | 1.206 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 45 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 67.270 kg |
Die Altivar HVAC ATH200-Reihe umfasst Frequenzumrichter, die für Erstausrüster (OEMs) im Bereich Heizungs-, Lüftungs- und Klimatechnik (HLK) zur Versorgung von Asynchron- und Synchronmotoren entwickelt wurden. Mit der Schutzart IP20 eignet sich der ATH230 für die Montage in Schaltschränken. Er versorgt 0.37kW/0.5PS Motoren bei einer Nennspannung von 200 bis 240 V. Das robuste Design mit beschichteten Leiterplatten der Klasse 3C3 gemäß IEC 60721-3-3 erhöht die Maschinenverfügbarkeit unter rauen Umgebungsbedingungen. Umgebungstemperaturen von bis zu 60 °C, ohne zusätzliche Kühlung. Sein kompaktes Design und native Funktionen wie Safe Torque Off, EMV-Filter und A2L-Zertifizierung optimieren das Bedienfeld und steigern die Wettbewerbsfähigkeit. HVAC- und programmierbare Logikfunktionen sind integriert, um das Automatisierungssystem zu vereinfachen. ATH200 verfügt über native Modbus-, BACnet MS/TP-Seriellschnittstellen und BACnet/IP-Konnektivität mit einem optionalen Kommunikationsmodul. Die Abmessungen betragen 72mm (Breite), 128mm (Tiefe), 143mm (Höhe) und er wiegt 1.0kg. ATH230 verwendet Kunststoff mit einem biobasierten Anteil von mehr als 20 % und Aluminium ist ASI-zertifiziert. Altivar HVAC ATH200 erfüllt die Anforderungen kompakter HLK-Anlagen, die Pumpen-, Lüfter- und Kompressoranwendungen abdecken. Es entspricht den Normen IEC/EN 81800-5-1 und IEC/EN 61800-3 und verfügt über die Zertifizierungen CE, cULus, UKCA, RCM, EAC, KC und ATEX. Für Altivar HVAC ATH200-Frequenzumrichter sind Montagezubehör und externe Optionen wie Netzdrosseln, Motordrosseln und zusätzliche EMV-Filter erhältlich. Die Verpackung besteht aus recyceltem Karton und enthält kein Einwegplastik. Es ist für die vertikale Montage (+/- 10 °) auf einer Platte mit 4 Befestigungslöchern ausgelegt. Die integrierten Funktionen und das ATH200-Design verbinden die Wettbewerbsfähigkeit kompakter HLK-Geräte mit Zuverlässigkeit, Effizienz und ökologischer Nachhaltigkeit. ATH230 bietet kompakte Lösungen ohne Kompromisse beim thermischen Verhalten, um das Design des HLK-Bedienfelds zu optimieren und gleichzeitig hohe Effizienz und Zuverlässigkeit zu gewährleisten.