Additional features
Network frequency50/60 Hz
[Ue] Rated operational voltage400 - 415 V AC 50/60 Hz
Earth fault trip technologyVoltage-independent
Rated breaking force and rated powerIdm 1500 A; IM 1500 A
Conditional rated short-circuit current10 kA
[Ui] Rated insulation voltage500 V AC 50/60 Hz
[Uimp] Rated impulse voltage withstand6 kV
Control typeToggle switch
Mounting modePlug-in
Mounting bracket35 mm DIN rail
9-mm pitch8
Height91 mm
Width72 mm
Depth73 mm
Product weight370 g
ColourWhite (RAL 9003)
Mechanical life20000 cycles
Electrical lifetime15000 cycles
Description of locking optionsPadlock
Connections - terminalsDouble terminal front side 1…35 mm² solid; Double terminal front side 1…25 mm² fine-stranded; Double terminal front side 1…25 mm² fine-stranded with ferrule; Double terminal rear side 1…25 mm² solid; Double terminal rear side 1…16 mm² fine-stranded; Double terminal rear side 1…16 mm² fine-stranded with ferrule
Wire stripping length14 mm for top or bottom connection
[M] tightening torque3.5 Nm top or bottom
Contact position indicatorJa
Contractual warranty
Warranty (in months)18
Main features
Product seriesActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameiID
Pole description4P
Neutral positionLeft
[In] Rated current40 A
Type of networkAC
Earth fault sensitivity30 mA
Earth fault protection time delayInstantaneous
Earth fault protection classType A
Mounting
StandardsEN/IEC 61008-1; EN/IEC 61008-2-1
Degree of protection (IP)IP20 corresponds to IEC 60529; IP40 (modular housing) corresponds to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse resistance, 250 A according to EN/IEC 61008-1
Operating ambient temperature-25…60 °C
Ambient temperature during storage-40…85 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height7,500 cm
VPE 1 width8,500 cm
VPE 1 length10,000 cm
Packaging weight (Lbs)379,000 g
VPE 2 typeS03
VPE 2 quantity27
VPE 2 height30,000 cm
VPE 2 width30,000 cm
VPE 2 length40,000 cm
VPE 2 weight10,634 kg
VPE 3 typeP12
VPE 3 quantity216
VPE 3 height45,000 cm
VPE 3 width80,000 cm
VPE 3 length120,000 cm
VPE 3 weight97,072 kg
The Acti9 iID residual current circuit breaker from Schneider Electric is a 4-pole device from the Acti9 series, designed for use in electrical distributions to protect against hazardous earth fault currents. With a rated current of 40 A and an earth fault sensitivity of 30 mA, it provides protection against direct contact, as required in residential and commercial spaces. The Type A protection class enables detection of pulsating earth fault currents, which is important for applications with electronic devices or non-linear loads. The tripping is instantaneous to ensure rapid disconnection in the event of an earth fault. The operating voltage is between 400 and 415 V AC at a frequency of 50/60 Hz, with an insulation voltage of 500 V AC. The rated impulse withstand voltage of 6 kV ensures reliability under transient voltage surges.

Residual current circuit breaker (RCCB) devices like the iID are essential for protective functions in electrical installations. This model is suitable for use in distribution enclosures and construction power distributors, complying with standards EN/IEC 61008-1 and EN/IEC 61008-2-1. The protection rating IP20 (in the device) and IP40 (in the modular housing) according to IEC 60529 ensures sufficient protection against contact and contamination. The pollution degree 3 indicates that the device is designed for environments with increased contamination risk. Electromagnetic compatibility with an impulse resistance of 250 A (8/20 µs) ensures stability under electromagnetic disturbances.

Technology explained clearly: The tripping mechanism is voltage-independent, meaning the protection operates regardless of the supply voltage. The snap-action switching ensures wear-free contact operation, increasing service life. The mechanical life is 20,000 cycles, and the electrical life is 15,000 cycles. The contact position indicator (VisiSafe) shows green when the output side is de-energized, which is important for maintenance work. The fault indication (VisiTrip) signals tripping due to overload or short circuit. The test button allows regular functional testing.

Compatibility and accessories: The device is mounted on a 35 mm DIN rail and has a 9 mm pitch width of 8. It can be combined with various auxiliary modules, such as undervoltage release (iMN), overvoltage release (iMSU), load current release (iMX), auxiliary switch (iOF), or fault indication switch (iSD). Compatible phase bars such as A9XPH412, A9XPH424, or A9XPH457 enable integration into larger distributions. The double terminals on the front and rear allow connection from both sides to cables or phase bars. The wire stripping length is 14 mm, and the tightening torque is 3.5 Nm.

Mounting and installation: Mounting is tool-free on the left side of the device. The front side is designed for attachment to a DIN rail. The device can be removed easily even with an installed phase bar, thanks to the front-accessible mounting element. The color is white (RAL 9003), enabling uniform visual design in distribution enclosures. The operating temperature range is -25 to 60 °C, and the storage temperature range is -40 to 85 °C.

Advantages in operation: The combination of high service life, mechanical and electrical reliability, and the possibility of expansion with additional modules makes the iID a flexible and robust protective device. The clear indication of contact position and fault tripping supports maintenance and safety. VDE certification confirms compliance with German safety standards.

Residual current circuit breaker (RCCB) devices like the iID are critical for safety in electrical installations. The combination of 4-pole configuration, Type A protection class, and 30 mA earth fault sensitivity makes it particularly suitable for applications where people must be protected from electrical hazards. The modular design and compatibility with various accessories increase application flexibility in different distribution systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/348038
qrcode für Schneider Electric A9Z21440 RCD 4-pole 40A