Schneider Electric A9Z21240, EAN: 3606480443015

Schneider Electric A9Z21240 residual current circuit breaker 2-pole 40 A

Installation > Modular devices / equipment installation > RCD

Schneider Electric A9Z21240 residual current circuit breaker 2-pole 40 A

Lieske Part No. 170708
Mfg Part No A9Z21240
EAN-Code 3606480443015
Manufacturer Schneider Electric
Here only 114,47 EUR
136,22 EUR incl. VAT

Further information for Schneider Electric A9Z21240 residual current circuit breaker 2-pole 40 A

Additional features
Network frequency50/60 Hz
[Ue] Rated operational voltage230 - 240 V AC 50/60 Hz
Earth fault trip technologyVoltage-independent
Rated breaking force and rated powerIdm 1500 A; IM 1500 A
Conditional rated short-circuit current10 kA
[Ui] Rated insulation voltage500 V AC 50/60 Hz
[Uimp] Rated impulse voltage withstand6 kV
Control typeToggle switch
Mounting modePlug-in
Mounting bracket35 mm DIN rail
9-mm pitch4
Height91 mm
Width36 mm
Depth73 mm
Product weight210 g
ColourWhite (RAL 9003)
Mechanical life20000 cycles
Electrical lifetime15000 cycles
Description of locking optionsPadlock
Connections - terminalsDouble terminal front side 1…35 mm² solid; Double terminal front side 1…25 mm² fine-stranded; Double terminal front side 1…25 mm² fine-stranded with ferrule; Double terminal rear side 1…25 mm² solid; Double terminal rear side 1…16 mm² fine-stranded; Double terminal rear side 1…16 mm² fine-stranded with ferrule
Wire stripping length14 mm for top or bottom connection
[M] tightening torque3.5 Nm top or bottom
Contact position indicatorJa
Contractual warranty
Warranty (in months)18
Main features
Product seriesActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameiID
Pole description2P
Neutral positionLeft
[In] Rated current40 A
Type of networkAC
Earth fault sensitivity30 mA
Earth fault protection time delayInstantaneous
Earth fault protection classType A
Mounting
StandardsEN/IEC 61008-1; EN/IEC 61008-2-1
Degree of protection (IP)IP20 corresponds to IEC 60529; IP40 (modular housing) corresponds to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse resistance, 250 A according to EN/IEC 61008-1
Operating ambient temperature-25…60 °C
Ambient temperature during storage-40…85 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height4,000 cm
VPE 1 width8,000 cm
VPE 1 length9,700 cm
Packaging weight (Lbs)222,000 g
VPE 2 typeS03
VPE 2 quantity54
VPE 2 height30,000 cm
VPE 2 width30,000 cm
VPE 2 length40,000 cm
VPE 2 weight12,587 kg
The residual current circuit breaker Acti9 iID from Schneider Electric is a 2-pole (2P) circuit breaker of the Acti9 series, designed for use in electrical distributions in indoor environments. It provides protection against dangerous earth fault currents and enables safe switching and disconnection of circuits. With a rated current of 40 A and an earth fault sensitivity of 30 mA, it meets the requirements for supplementary protection against direct contact, as commonly used in residential and commercial rooms. The protection class Type A ensures detection of pulsating earth fault currents, which is particularly important for devices with electronic power supplies. The operating voltage is 230–240 V AC at a frequency of 50/60 Hz, and the rated insulation voltage is 500 V AC, enabling use in installations with higher voltage levels.

Applications
This circuit breaker is suitable for use in electrical distributions in residential and commercial buildings, as well as in construction power distributors. It protects against direct and indirect contact, with the 30 mA sensitivity ensuring protection against fatal electric shocks. In case of insulation faults or defective devices, earth fault currents from 100 mA to 300 mA are detected, minimizing the risk of fire or electric shock. The tripping time is instantaneous, enabling rapid response in hazardous situations. The rated breaking capacity of 1500 A and the conditional rated short-circuit current of 10 kA ensure reliable operation even under high loads and short-circuit conditions.

Functions and Equipment in Detail
The switch features a mechanical front-mounted fault indication (VisiTrip), which visually indicates tripping due to overload or short circuit. The safe contact indication (VisiSafe) shows in green that the outgoing side is de-energized, which is important for maintenance and inspection work. An integrated test button allows regular functional testing to ensure the reliability of the switch. The spring-loaded switching mechanism ensures wear-free contact switching, increasing the service life. The mechanical life is 20,000 cycles, and the electrical life is 15,000 cycles.

Technology Explained Simply
The circuit breaker operates using voltage-independent earth fault tripping technology, meaning it responds to earth fault currents regardless of the supply voltage. The dual terminals on the front and rear allow for two-sided connection of cables or phase bars, enabling flexible and efficient installation. The wire stripping length is 14 mm, and the tightening torque for the terminals is specified as 3.5 Nm. Installation is tool-free on a 35 mm DIN rail, with the device mounted on the left side. The height is 91 mm, the width 36 mm, and the depth 73 mm, corresponding to the 4-fold 9 mm grid. The color is white (RAL 9003).

Compatibility and Accessories
The circuit breaker can be extended with various optional auxiliary modules. These include the under-voltage release (iMN), the over-voltage release (iMSU), the load current release (iMX), the auxiliary switch for status indication (iOF), and the fault indication switch (iSD). These modules can be mounted in series on the device to integrate additional functions such as remote control, status indication, or emergency stop functionality. Compatible phase bars such as A9XPH557 (3P+N, 57TE) or A9XPH512 (3P+N, 12TE) enable flexible integration into distributions. Installation is on a 35 mm DIN rail, and the device can be easily removed even with an installed phase bar, thanks to the front-accessible mounting element.

Mounting and Installation
Installation is tool-free on a 35 mm DIN rail, with the device mounted on the left side. The terminals are designed for various conductor cross-sections: front side up to 35 mm² solid and 25 mm² stranded (with or without wire end ferrule), rear side up to 25 mm² solid and 16 mm² stranded (with or without wire end ferrule). The degree of protection is IP20 (IEC 60529), suitable for use in enclosed switchgear. In modular use within an enclosure, the degree of protection is IP40. The pollution degree is specified as 3, indicating an environment with increased pollution risk. The ambient temperature during operation ranges from -25 °C to 60 °C, and during storage from -40 °C to 85 °C.

Operational Advantages
The circuit breaker offers high reliability through the combination of mechanical and electrical life, as well as integrated indicators for faults and de-energized status. Tool-free mounting and two-sided terminal connections simplify installation and maintenance. Compatibility with optional auxiliary modules extends functionality and allows adaptation to specific requirements. Compliance with standards EN/IEC 61008-1 and EN/IEC 61008-2-1, as well as VDE certification, guarantees the safety and quality of the device. The rated impulse voltage withstand of 6 kV protects against transient voltage surges, increasing operational robustness.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/170708
qrcode für Schneider Electric A9Z21240 residual current circuit breaker 2-pole 40 A