| Complementary |
| Number of ways | 28 ways N + 1 L |
| Distribution type | N L |
| Poles configuration for 1 way | 1 x 1P + N; 1 x 2P |
| Connection pitch | 18 mm |
| Connector type | Tooth |
| Distance between way | 36 mm |
| Marking | N L |
| Insulation | Insulated |
| Device presentation | Cuttable |
| Provided equipment | Set of 10 end piece |
| [Ie] rated operational current | 100 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC |
| [Ui] rated insulation voltage | 500 V AC conforming to IEC 61439-2 |
| Mounting location | Top or bottom on tunnel type terminals; Top or bottom on double terminal |
| 9 mm pitches | 114 |
| Width | 1000 mm |
| Colour | White (RAL 9003) |
| Range compatibility | Acti9 iC60; Acti9 iK60; Acti9 iID; Acti9 iID K; Acti9 iSW; Acti9 iSW-NA; Multi9 C60 |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Fire resistance | 960 °C ( 30 s ) conforming to IEC 60695-2-1 |
| Pollution degree | 3 conforming to IEC 60947-7-1 |
| IP degree of protection | IP20 with end-pieces and tooth covers |
| Logistical informations |
| Country of origin | DE |
| Main |
| Range | Acti9 |
| Product or component type | Comb busbar |
| Mounting mode | Horizontal |
| Accessory / separate part category | Connection accessory |
| Lines description | 1L + N |
| Length in 18 mm modules | 57 |
| Standards | EN/IEC 61439-1 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 0.540 cm |
| Package 1 Width | 0.900 cm |
| Package 1 Length | 104.000 cm |
| Package 1 Weight | 393.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 5.400 cm |
| Package 2 Width | 105.000 cm |
| Package 2 Length | 9.000 cm |
| Package 2 Weight | 2.150 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 270 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 135.120 kg |
The Phase Bar Strip A9XPH257 belongs to the Acti9 series from Schneider Electric and serves as connection accessory for installing circuit breakers and other devices in distribution boards. It is designed as a 2-pole comb bar for distributing lines in the format 1L + N. The bar is cuttable, allowing application-specific adjustment of length. With a total length of 57 modules on an 18-mm grid (equivalent to 1000 mm width), it provides sufficient space for multiple devices in a distribution board. The rated operational voltage is 415 V AC, and the rated insulation voltage is 500 V AC, complying with standard IEC 61439-2. The rated operational current is 100 A at an ambient temperature of 40 °C. The bar is suitable for use in distribution boards with a protection rating of IP20, provided end caps and tine covers are installed. The color is white (RAL 9003), ensuring clear visibility and good harmonization with other components of the Acti9 series.
Applications
The Phase Bar Strip is used in electrical distribution boards to connect multiple switches or fuses to a common line. It is particularly suitable for installations where clear and secure distribution of phase and neutral lines is required. The bar can be mounted horizontally and is designed for mounting at the top or bottom on tunnel terminals or double terminals. The pole configuration includes 28-pole N + 1 L, with distribution as 1 x 1P + N and 1 x 2P. The marking “N L” supports clear identification of the lines.
Functions and Equipment in Detail
The bar features a tine connection type, ensuring a secure and stable connection to devices. The distance between poles is 36 mm, meeting electrical safety requirements. The bar is insulated to prevent short circuits and ensure shock protection. It is designed for pollution degree 3 according to IEC 60947-7-1, indicating suitability for environments with increased pollution risk. The fire resistance is 960 °C for 30 seconds, complying with IEC 60695-2-1 and enhancing safety in case of fire.
Technology Explained Simply
The bar is designed as a comb bar with a series of tines to which devices are connected. The tines allow for quick and secure installation without additional tools. The cuttable design offers flexibility during installation, as it can be trimmed to the required length. Standards EN/IEC 61439-1 and IEC 61439-2 ensure compliance with safety and functional requirements for low-voltage distribution equipment. The IP20 protection rating protects against contact with moving parts and prevents entry of solid foreign objects larger than 12.5 mm.
Compatibility and Accessories
The Phase Bar Strip is compatible with various products from the Acti9 series, including models iC60, iK60, iID, iID K, iSW, iSW-NA, and Multi 9 C60. As accessories, a set of 10 end caps is included in the delivery, used for finishing the ends of the bar. Additional components such as feed terminals (e.g., A9XPCD04) or shock protection covers (e.g., A9XPT920) can be used to complete the installation. The end caps A9XPE210 are also suitable and support secure end finishing.
Mounting and Installation
Mounting is done horizontally in the distribution board, with the bar fixed at the top or bottom onto tunnel terminals or double terminals. The tines of the bar are connected to the terminal clamps of the devices. The cuttable feature allows precise adaptation to existing mounting conditions. End caps are mounted at the ends of the bar to ensure secure finishing. The bar is designed for mounting in distribution boards complying with standards IEC 61439-1 and IEC 61439-2.
Operational Advantages
The Phase Bar Strip provides reliable and secure distribution of electrical lines. The cuttable design and compatibility with various devices from the Acti9 series increase installation flexibility. High fire resistance and pollution degree 3 enhance safety in use. Clear marking and insulation of the bar support safe and orderly installation and maintenance. The IP20 protection rating ensures sufficient protection against contact and foreign objects in indoor installations.