| Additional features |
| Device position in system | Outlet |
| Earth fault trip technology | Voltage-independent |
| [Ui] Rated insulation voltage | 500 V AC 50/60 Hz corresponds to IEC 60947-2 |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947-2 |
| Compatible product family | Acti9 iC60 circuit breaker |
| Product compatibility | IC60H/N double terminal miniature circuit-breaker |
| Local signalling | trip indicator |
| Mounting mode | Plug-in |
| Mounting bracket | DIN rail |
| Electrical connection for LS switch | With screws |
| Height | 91 mm |
| Width | 117 mm |
| Depth | 74 mm |
| Product weight | 0,21 kg |
| Connections - terminals | Tunnel terminals bottom side 1…35 mm² solid; tunnel terminals bottom side 1…25 mm² stranded |
| Wire stripping length | 14 mm |
| [M] tightening torque | 3,5 Nm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | Acti9 |
| Product name | Acti9 Vigi iC60 |
| Product or component type | Additional residual current protective devices |
| Device short name | Vigi iC60 |
| Pole description | 3P |
| [In] Rated current | 63 A |
| Earth fault sensitivity | 300 mA |
| Earth fault protection time delay | Selective |
| Residual current protection type | Type A-SI (Superimmunized) |
| Type of network | AC |
| Network frequency | 50/60 Hz |
| [Ue] Rated operational voltage | 400 V AC 50/60 Hz complies with EN 61009-1; 230/415 V AC 50/60 Hz complies with IEC 61009-1 |
| Standards | EN 61009-1; IEC 61009-1 |
| 9-mm pitch | 7 |
| Mounting |
| Degree of protection (IP) | IP20 corresponds to IEC 60529; IP40 (modular housing) corresponds to IEC 60529 |
| Pollution degree | 3 corresponds to IEC 60947-2 |
| Electromagnetic compatibility | 8/20 µs impulse impedance, 3.000 A corresponds to IEC 61009-1 |
| Operating ambient temperature | -25…60 °C |
| Ambient temperature during storage | -40…85 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 8,800 cm |
| VPE 1 width | 11,500 cm |
| VPE 1 length | 14,000 cm |
| Packaging weight (Lbs) | 228,000 g |
| VPE 2 type | S03 |
| VPE 2 quantity | 15 |
| VPE 2 height | 30,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 3,918 kg |
FI block Acti 9 Vigi iC60N/H. 3-pole, nominal current 63A, nominal residual current 300mA, type A, selective, SI, operating voltage (Ue) 400-415V AC, insulation voltage (Ui) 500V AC. Can be mounted on the right-hand side of the iC60N/H series circuit breaker. Tripping due to residual current is indicated by a red, mechanical indicator on the knob. Terminals IP 20. Test button for regular function testing. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - fault signaling switch, auxiliary switch, undervoltage release, overvoltage release, shunt release. The Vigi iC60N/H FI block meets the following standards - IEC/EN 61009-1. This series is also VDE certified!