Schneider Electric A9W21263, EAN: 3606480443428

Schneider Electric A9W21263 residual current circuit breaker 2-pole 63A

Installation > Modular devices / equipment installation > RCD

Schneider Electric A9W21263 residual current circuit breaker 2-pole 63A

Lieske Part No. 561185
Mfg Part No A9W21263
EAN-Code 3606480443428
Manufacturer Schneider Electric
Here only 301,15 EUR
358,37 EUR incl. VAT

Further information for Schneider Electric A9W21263 residual current circuit breaker 2-pole 63A

Additional features
Device position in systemOutlet
Earth fault trip technologyVoltage-independent
[Ui] Rated insulation voltage500 V AC 50/60 Hz corresponds to IEC 60947-2
[Uimp] Rated impulse voltage withstand6 kV corresponds to IEC 60947-2
Compatible product familyActi9 iC60 circuit breaker
Product compatibilityIC60H/N double terminal miniature circuit-breaker
Local signallingtrip indicator
Mounting modePlug-in
Mounting bracketDIN rail
Electrical connection for LS switchWith screws
Height91 mm
Width72 mm
Depth74 mm
Product weight0,165 kg
Connections - terminalsTunnel terminals bottom side 1…35 mm² solid; tunnel terminals bottom side 1…25 mm² stranded
Wire stripping length14 mm
[M] tightening torque3,5 Nm
Contractual warranty
Warranty (in months)18
Main features
Product seriesActi9
Product nameActi9 Vigi iC60
Product or component typeAdditional residual current protective devices
Device short nameVigi iC60
Pole description2P
[In] Rated current63 A
Earth fault sensitivity30 mA
Earth fault protection time delayInstantaneous
Residual current protection typeType A
Type of networkAC
Network frequency50/60 Hz
[Ue] Rated operational voltage230/400 V AC 50/60 Hz conforms to EN 61009-1; 230/240 V AC 50/60 Hz conforms to IEC 61009-1
StandardsEN 61009-1; IEC 61009-1
9-mm pitch4
Mounting
Degree of protection (IP)IP20 corresponds to IEC 60529; IP40 (modular housing) corresponds to IEC 60529
Pollution degree3 corresponds to IEC 60947-2
Electromagnetic compatibility8/20 µs impulse resistance, 250 A corresponds to IEC 61009-1
Operating ambient temperature-25…60 °C
Ambient temperature during storage-40…85 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height8,2 cm
VPE 1 width7,8 cm
VPE 1 length11,3 cm
Packaging weight (Lbs)189,0 g
VPE 2 typeS03
VPE 2 quantity27
VPE 2 height30 cm
VPE 2 width30 cm
VPE 2 length40 cm
VPE 2 weight5,587 kg
The product A9W21263 from Schneider Electric is a residual current circuit breaker of the Acti9 series, specifically designed as a Vigi iC60. It is a 2-pole RCD module intended to be mounted as an additional residual current protection device on circuit breakers of the iC60N/H series. The device is designed for use in electrical installations where high safety against dangerous fault currents is required, particularly in residential and commercial buildings as well as industrial installations with increased protection requirements.

Applications
This RCD module is designed for use in electrical distributions requiring a residual current sensitivity of 30 mA. This sensitivity is typical for protection measures against electric shock, especially in areas with increased risk of contact, such as bathrooms, kitchens, or workshops. The instantaneous tripping upon detection of a fault current ensures rapid disconnection to protect people from dangerous currents. The operating voltage is 230/400 V AC at 50/60 Hz, enabling use in standard power networks in Europe and other regions with corresponding voltage levels.

Functions and Features in Detail
The device features a trip indication, visible via a red mechanical marking on the handle, indicating whether tripping occurred due to a fault current. This facilitates maintenance and quick identification of faults. A test button allows regular functional testing to ensure the reliability of the protective device. The residual current tripping technology is voltage-independent, meaning the protection remains functional even during voltage dips or outages. The residual current protection type is Type A, enabling detection of pulsating direct current components, such as those occurring in devices with electronic power supplies.

Technical Explanation
The tripping unit operates using thermal-magnetic technology, allowing the device to respond to both overloads (thermally) and short circuits (magnetically). The rated insulation voltage is 500 V AC, ensuring sufficient electrical insulation for use in distribution switchgear. The rated impulse withstand voltage of 6 kV protects the device against transient voltage surges caused by lightning strikes or switching operations. The protection rating IP20 for the terminals means the device is protected against contact with fingers and against solid foreign objects, but not against splashing water or dust. In the modular enclosure, a protection rating of IP40 is provided, offering protection against splashing water and larger foreign objects.

Compatibility and Accessories
The RCD module is specifically designed for mounting on circuit breakers of the iC60N/H series and can be clipped on to the right side of these devices. Compatibility includes both iC60H and iC60N variants with dual terminal connections. Additionally, auxiliary modules such as fault alarm switches, auxiliary switches, under-voltage release, over-voltage release, or load current release can be connected to extend the functionality of the switch. Mounting is done on a DIN rail, enabling standardized and secure installation in enclosures.

Mounting and Installation
Mounting is performed by clipping onto the corresponding circuit breaker. Electrical connections are made via tunnel terminals on the underside, designed for solid cable up to 35 mm² and flexible cable up to 25 mm². The wire stripping length is 14 mm, and the torque for the terminals is 3.5 Nm. The dimensions of the device are 91 mm (height), 72 mm (width), and 74 mm (depth), mounted on a 9 mm grid. The operating ambient temperature ranges from -25 °C to 60 °C, allowing use in a wide variety of environments.

Operational Advantages
The RCD module provides reliable protection against dangerous fault currents with high sensitivity of 30 mA. The mechanical trip indication and test button simplify maintenance and functional checks. Compatibility with the iC60 series and the ability to connect additional auxiliary modules increase flexibility and adaptability to specific requirements. Compliance with standards IEC/EN 61009-1 and VDE certification guarantee the safety and quality of the product. The operating voltage and insulation voltage are designed for typical distribution systems, enabling universal use in various applications.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/561185
qrcode für Schneider Electric A9W21263 residual current circuit breaker 2-pole 63A