| Complementary |
| Device location in system | Outgoer |
| Residual current tripping technology | Voltage independent |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Range compatibility | Acti9 iC60 miniature circuit-breaker; Acti9 Reflex iC60 integrated control circuit breaker |
| Product compatibility | IC60a/N/H/L/P single terminal miniature circuit-breaker |
| Local signalling | Trip indicator |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Electrical connection to mcb | By screws |
| Comb busbar and distribution block compatibility | Bottom: YES |
| Height | 91 mm |
| Width | 63 mm |
| Depth | 73.5 mm |
| Net weight | 0.165 kg |
| Connections - terminals | Tunnel type terminal downside for 1 cable(s) 1…25 mm² rigid without cable end; Tunnel type terminal downside for 1 cable(s) 1…16 mm² flexible without cable end; Tunnel type terminal downside for 1 cable(s) 1…16 mm² flexible with cable end |
| Wire stripping length | 14 mm for bottom connection |
| Tightening torque | 2 N.m bottom |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60947-2 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1 |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | Acti9 |
| Product name | Acti9 Vigi iC60 |
| Product or component type | Add-on residual current device |
| Device short name | Vigi iC60 |
| Poles description | 2P |
| [In] rated current | 25 A |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection time delay | Instantaneous |
| Earth leakage protection type | Type A-SI (Super Immunised) |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1; 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 |
| Standards | EN/IEC 61009-1; EN/IEC 61009-2-1 |
| 9 mm pitches | 3 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 8.700 cm |
| Package 1 Length | 12.000 cm |
| Package 1 Weight | 140.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 27 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 4.224 kg |
FI block Acti 9 Vigi iC60L. 2-pole, nominal current 25A, nominal residual current 30mA, type A, SI, operating voltage (Ue) 400-415V AC, insulation voltage (Ui) 500V AC. Can be mounted on the right-hand side of the iC60L series circuit breaker. Tripping due to residual current is indicated by a red, mechanical indicator on the knob. Terminals IP 20. Test button for regular function testing. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - fault signaling switch, auxiliary switch, undervoltage release, overvoltage release, shunt release. The Vigi iC60L FI block meets the following standards - IEC/EN 61009-1. This series is also VDE certified!