| Additional features |
| Rated operating current Ie | 50 A DC-21A 1.000 V DC 40 °C; 63 A DC-21A 1.000 V DC 5 °C; 61 A DC-21A 1.000 V DC 10 °C; 60 A DC-21A 1.000 V DC 15 °C; 58 A DC-21A 1.000 V DC 20 °C; 56 A DC-21A 1.000 V DC 25 °C; 54 A DC-21A 1.000 V DC 30 °C; 52 A DC-21A 1.000 V DC 35 °C; 48 A DC-21A 1.000 V DC 45 °C; 46 A DC-21A 1.000 V DC 50 °C; 41 A DC-21A 1.000 V DC 60 °C; 35 A DC-21A 1.000 V DC 70 °C |
| Voltage drop | 251 mV 5.02 MΩ 12.54 W 50 A |
| [Ui] Rated insulation voltage | 1000 V DC |
| [Uimp] Rated impulse voltage withstand | 6 kV |
| Polarity sensitivity | Yes (+ and - has to be respected for connection) |
| Control type | Toggle switch |
| Mounting mode | Fixed |
| Mounting bracket | 35 mm symmetrical DIN rail |
| 9-mm pitch | 8 |
| Height | 132,7 mm |
| Width | 72 mm |
| Depth | 77,4 mm |
| Product weight | 0,53 kg |
| Colour | White |
| Mechanical life | 20000 cycles |
| Electrical lifetime | 3000 cycles |
| Connections - terminals | Tunnel terminal (top) 1…35 mm² solid; Tunnel terminal (top) 1…25 mm² fine-stranded; pre-wired cable (bottom) |
| [M] tightening torque | 3,5 Nm |
| Compatibility code | SW60-DC |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | SW60 |
| Product or component type | Disconnect switch |
| Device short name | SW60-DC |
| Switching application | photovoltaic inverter protection |
| Pole description | 2P |
| Application category | DC-21A |
| Suitability for insulation | Yes, complies with EN/IEC 60947-3 |
| Mounting |
| Standards | EN/IEC 60947-3 |
| Pollution degree | 2 |
| Operating ambient temperature | -25…70 °C |
| Ambient temperature during storage | -40…85 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 8,300 cm |
| VPE 1 width | 7,700 cm |
| VPE 1 length | 14,500 cm |
| Packaging weight (Lbs) | 543,000 g |
| VPE 2 type | S03 |
| VPE 2 quantity | 30 |
| VPE 2 height | 30,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 16,882 kg |
| VPE 3 type | P06 |
| VPE 3 quantity | 240 |
| VPE 3 height | 75,000 cm |
| VPE 3 width | 60,000 cm |
| VPE 3 length | 80,000 cm |
| VPE 3 weight | 146,776 kg |
C60N Multi 9 OEM circuit breaker, 10 kA (IEC/EN 60947-2). 1-pole, nominal current 1A, C characteristic, operating voltage (Ue) 240V AC / 72V DC, insulation voltage (Ui) 500V AC. Single connection terminal for cable and pin comb bar on the top and bottom of the device. Fastened using a normal clip fastener on a DIN rail. Snap action for low-wear switching of the contacts. C60 circuit breakers are designed for a long service life and heavily used industrial environments. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - display of switch position (OF), fault tripping (SD), shunt release (MX, MX+OF), undervoltage release (MN, MNs, MNx). Tool-free installation on the left side of the device. The C60N complies with the following standards: IEC60947-2.