Further information for Schneider Electric A9N61524 circuit breaker 2-pole C 4A
Complementary
Network frequency
50/60 Hz
[Ue] rated operational voltage
500 V DC
[Ics] rated service breaking capacity
15 kA 75 % conforming to EN 60947-2 - 220 V DC; 15 kA 75 % conforming to IEC 60947-2 - 220 V DC; 15 kA 75 % conforming to EN 60947-2 - 250 V DC; 15 kA 75 % conforming to IEC 60947-2 - 250 V DC; 4.5 kA 75 % conforming to EN 60947-2 - 500 V DC; 4.5 kA 75 % conforming to IEC 60947-2 - 500 V DC; 7.5 kA 75 % conforming to EN 60947-2 - 440 V DC; 7.5 kA 75 % conforming to IEC 60947-2 - 440 V DC
[Ui] rated insulation voltage
500 V DC conforming to IEC 60947-2; 500 V DC conforming to EN 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2; 6 kV conforming to IEC 60947-2
Control type
Toggle
Local signalling
ON/OFF indication
Mounting mode
Fixed
Mounting support
35 mm symmetrical DIN rail
Comb busbar and distribution block compatibility
Top or bottom: standard
9 mm pitches
4
Net weight
0.256 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
3000 cycles L/R = 2 ms
Provision for padlocking
Padlockable
Locking options description
In position O
Tightening torque
Power circuit: 2.5 N.m top or bottom
Earth-leakage protection
Without
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
Pollution degree
3 conforming to EN 60947-2; 3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-2
Operating altitude
2000 m
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…85 °C
Logistical informations
Country of origin
CN
Main
Range
Acti9
Product name
Acti9 C60H-DC
Product or component type
Miniature circuit-breaker
Device short name
C60H-DC
Device application
Distribution
Poles description
2P
Number of protected poles
2
[In] rated current
4 A at 25 °C
Network type
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
10 kA Icu at 440 V DC conforming to EN 60947-2; 10 kA Icu at 440 V DC conforming to IEC 60947-2; 6 kA Icu at 500 V DC conforming to EN 60947-2; 6 kA Icu at 500 V DC conforming to IEC 60947-2; 20 kA Icu at 220 V DC conforming to GB 14048.2; 20 kA Icu at 220 V DC conforming to IEC 60947-2; 20 kA Icu at 250 V DC conforming to GB 14048.2; 20 kA Icu at 250 V DC conforming to IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2; Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to IEC 60947-2; Yes conforming to EN 60947-2
Standards
EN 60947-2; IEC 60947-2
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.500 cm
Package 1 Width
7.200 cm
Package 1 Length
8.400 cm
Package 1 Weight
226.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.500 cm
Package 2 Width
9.100 cm
Package 2 Length
22.600 cm
Package 2 Weight
1.416 kg
Unit Type of Package 3
S03
Number of Units in Package 3
72
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
17.479 kg
Leitungsschutzschalter C60N Multi 9 OEM, 10 kA (IEC/EN 60947-2). 3-polig, Nennstrom 10A, B-Charakteristik, Betriebsspannung (Ue) 415V AC / 125V DC, Isolationsspannung (Ui) 500V AC. Einfach-Anschlussklemme für Kabel und Stiftkammschiene an der Geräteober- und unterseite. Befestigung über normalen Clipverschluss auf DIN-Schiene. Sprungschaltung für verschleißarmes Schalten der Kontakte. Leitungsschutzschalter C60 sind für eine hohe Lebensdauer und stark beanspruchte industrielle Umgebungen ausgelegt. Technologie der Auslöseeinheit- thermomagnetisch. Zusätzlich anreihbare Hilfsmodule (optional)- Anzeige von Schaltstellung (OF), Fehlerauslösung (SD), Arbeitsstromauslöser (MX, MX+OF), Unterspannungsauslöser (MN, MNs, MNx). Werkzeuglose Montage linksseitig am Gerät. Der C60N erfüllt folgende Normen- IEC60947-2.