Schneider Electric A9L40601, EAN: 3606480506345

Schneider Electric A9L40601 surge arrester 3p+N 350 V

Energy > Surge Protection

Schneider Electric A9L40601 surge arrester 3p+N 350 V

Lieske Part No. 1337897
Mfg Part No A9L40601
EAN-Code 3606480506345
Manufacturer Schneider Electric
Here only 374,30 EUR
445,42 EUR incl. VAT

Further information for Schneider Electric A9L40601 surge arrester 3p+N 350 V

Complementary
Surge arrester class typeType 2
Surge arrester technologyMOV + GDT
[Ue] rated operational voltage230/400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge currentCommon mode: 15 kA (L/PE); Common mode: 15 kA (N/PE); Differential mode: 15 kA (L/N)
Maximum discharge currentCommon mode: 40 kA L/PE; Common mode: 40 kA N/PE; Differential mode: 40 kA L/N
[Uc] maximum continuous operating voltageCommon mode: 260 V N/PE; Common mode: 350 V L/PE; Differential mode: 350 V L/N
Maximum [Up] voltage protection levelCommon mode 1.4 kV type 2 N/PE; Differential mode 1.4 kV type 2 L/N
[Ut] temporary overvoltage337 V L/N 5 s withstand; 1200 V N/PE 200 ms safe failure mode; 442 V L/PE 5 s withstand; 1453 V L/PE 200 ms safe failure mode
Disconnector device typeAssociated circuit breaker iC60H 40 A curve C - Icu 15 kA; Associated circuit breaker IC60N 40 A curve C - Icu 10 kA; Associated circuit breaker NG125H 40 A curve C - Icu 36 kA; Associated circuit breaker NG125L 40 A curve C - Icu 50 kA; Associated circuit breaker NG125N 40 A curve C - Icu 25 kA; Associated fuse gG 63 A - Icu 15 kA; Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage0.25 A/250 V AC 50/60 Hz
Mounting modeClip-on (DIN rail)
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.421 kg
ColourWhite (RAL 9003)
[Ipe] Ground residual current0.6 mA; 0.003 mA
Connections - terminalsTunnel type terminal (downside) 2.5…35 mm²; Tunnel type terminal (upside) 2.5…35 mm²
Tightening torque2.5 N.m
Compatibility codeIPRD40r
Contractual warranty
Warranty (in months)18
Environment
IK degree of protectionIK03 conforming to IEC 62262
Relative humidity5…95 %
Operating altitude2000 m
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…85 °C
Logistical informations
Country of originCN
Main
Range of productIPRD
Product nameActi9 iPRD
Product or component typeSurge arrester with pluggable cartridge
Device short nameiPRD40r
Device applicationDistribution
StandardsEN 61643-11:2012; IEC 61643-11:2011
Product certificationsCE
Quality labelsNF; KEMA-KEUR
Poles description3P + N
Remote signallingWith
Signal contacts composition1 SD (1 C/O)
Surge arrester typeElectrical distribution network
Earthing systemTT; TN-S
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8 cm
Package 1 Width8.3 cm
Package 1 Length9.3 cm
Package 1 Weight452 g
Unit Type of Package 2BB1
Number of Units in Package 23
Package 2 Height9 cm
Package 2 Width10 cm
Package 2 Length28 cm
Package 2 Weight1.424 kg
Unit Type of Package 3S03
Number of Units in Package 327
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight13.363 kg
The surge arrester Acti 9 iPRD40r from Schneider Electric is a plug-in protection module for electrical distribution networks, designed for use in 3-pole + N systems. It provides protection against overvoltages, particularly in installations with TT and TN-S earthing systems. The device is part of the IPRD series and belongs to the Acti9 product range, with the short designation iPRD40r indicating the model variant. The technology is based on a combination of MOV (Metal-Oxide Varistor) and GDT (Gas-Discharge Tube), enabling efficient overvoltage diversion. The arrester is classified as Type 2 according to EN 61643-11:2012 and IEC 61643-11:2011, making it suitable for installation in distribution enclosures.

Applications
The iPRD40r is intended for use in industrial and commercial electrical installations, particularly in distribution systems where high reliability during transient overvoltages is required. It protects electrical devices and systems from damage caused by lightning surges or induced voltage spikes in the network. The application is in TT and TN-S earthing systems, with a rated voltage of 230/400 V AC (±10 %) at 50/60 Hz. The maximum discharge capacity is 40 kA in common mode (L/PE and N/PE) and differential mode (L/N), ensuring high load capacity during short-term high-voltage impulses.

Functions and Equipment in Detail
The device features an integrated remote signaling contact, configured as a signal contact with 1 SD (1 W). This enables remote monitoring of the operational status, for example in automation systems or alarm installations. The signal circuit voltage is 0.25 A/250 V AC, ensuring compatibility with common control and monitoring systems. The protection level (Up) is 1.4 kV in common mode (N/PE) and differential mode (L/N), providing effective shielding against overvoltages. The maximum continuous voltage (Uc) is 350 V in common mode (L/PE and N/PE) and differential mode (L/N), ensuring operational safety under normal network conditions.

Technology Explained Simply
The surge arrester operates on the principle of voltage diversion: when an overvoltage occurs, the arrester activates and diverts the energy through the protective earth conductor (PE) to protect connected devices. The combination of MOV and GDT ensures rapid response and high energy diversion. The maximum discharge capacity (Imax) of 40 kA demonstrates the device's performance under extreme loads. The temporary overvoltage (TOV) is specified as 337 V L/N (5 s withstand) and 1200 V N/PE (200 ms safe failure mode), documenting stability under transient conditions. The protective earth currents (Ipe) are 0.6 mA (L/PE) and 0.003 mA (N/PE), indicating low load on the protective earth conductor under normal operating conditions.

Compatibility and Accessories
The iPRD40r is designed for mounting on DIN rails and conforms to the 9 mm pitch with a height of 85 mm. It is compatible with various disconnectors from the iC60H, iC60N, NG125H, NG125L, and NG125N series, each with 40 A and curve C. Additionally, gG fuses with 63 A (Icu 15 kA) or 80 A (Icu 50 kA) can be used as network-side overcurrent protection. Suitable accessories include, for example, the circuit breaker NG125L 4-pole C 40A or the LS switch iC60H 4p C 40A, which are suitable for safe integration into existing switchgear installations.

Mounting and Installation
Mounting is done by plugging onto a DIN rail, with connection terminals designed as tunnel terminals supporting cross-sections from 2.5 to 35 mm². The tightening torque is 2.5 Nm. The operating temperature ranges from -25 °C to 60 °C, and the storage temperature ranges from -40 °C to 85 °C. The relative humidity is 5 to 95 %, and the operating altitude is limited to 2,000 m. The protection rating corresponds to IK03 according to IEC 62262, providing protection against mechanical impacts such as shocks or vibrations. The device color is white (RAL 9003), enabling uniform visual design in distribution enclosures.

Advantages in Operation
The iPRD40r offers high reliability through the combination of MOV and GDT, along with the integrated remote signaling function, enabling quick fault detection. The plug-in design simplifies maintenance and replaceability, thereby increasing the operational uptime of installations. Compatibility with various disconnectors and fuses allows flexible integration into existing systems. Certifications CE, NF, and KEMA-KEUR confirm compliance with European and international standards, ensuring safe use in various application areas.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1337897
qrcode für Schneider Electric A9L40601 surge arrester 3p+N 350 V