| Complementary |
| Surge arrester class type | Type 1 + 2 |
| Surge arrester technology | MOV + GDT |
| [Ue] rated operational voltage | 230/400 V AC (+/- 10 %) at 50/60 Hz |
| Nominal discharge current | 20 kA |
| Maximum discharge current | 50 kA |
| [Iimp] impulse current | Common mode: 50 kA N/PE; Differential mode: 12.5 kA L/N |
| [Uc] maximum continuous operating voltage | Differential mode: 350 V L/N; Common mode: 255 V N/PE |
| Maximum [Up] voltage protection level | 1.5 kV type 1 + 2 |
| Residual current | 0.003 mA N/PE |
| [Ut] temporary overvoltage | 337 V L/N 5 s withstand; 1200 V N/PE 200 ms safe failure mode |
| Disconnector device type | Associated fuse gG 160 A 120 kA standard; Associated circuit breaker Compact NSX160E 80 A 25 kA standard |
| Local signalling | Operating: mechanical indicator (white); End of life: mechanical indicator (red) |
| Mounting mode | Clip-on (DIN rail) |
| 9 mm pitches | 8 |
| Height | 89 mm |
| Width | 72 mm |
| Depth | 69 mm |
| Net weight | 619 g |
| Colour | White (RAL 9003) |
| Material | PA6 |
| Connections - terminals | Tunnel type terminal (phase) 10…25 mm² flexible; Tunnel type terminal (phase) 10…35 mm² rigid; Tunnel type terminal (earth) 16…25 mm² flexible; Tunnel type terminal (earth) 16…35 mm² rigid |
| Wire stripping length | 14 mm |
| Tightening torque | 3.5 N.m |
| Impulse current | 12.5 kA |
| Compatibility code | IPRD1 |
| Market segment | Small commercial; Residential |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IK degree of protection | IK05 conforming to IEC 62262 |
| Pollution degree | 3 |
| Relative humidity | 5…95 % |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…80 °C |
| Logistical informations |
| Country of origin | CN |
| Main |
| Range of product | IPRD1 |
| Product name | Acti9 iPRD1 |
| Product or component type | Surge arrester with pluggable cartridge |
| Device short name | iPRD1 12.5 |
| Device application | Distribution |
| Standards | EN 61643-11:2012; IEC 61643-11:2011 |
| Quality labels | CE; EAC; VDE |
| Poles description | 3P + N |
| Remote signalling | With |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Earthing system | TT; TN-S |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.000 cm |
| Package 1 Width | 8.000 cm |
| Package 1 Length | 9.300 cm |
| Package 1 Weight | 650.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 8.300 cm |
| Package 2 Width | 10.000 cm |
| Package 2 Length | 27.700 cm |
| Package 2 Weight | 2.017 kg |
| Unit Type of Package 3 | S02 |
| Number of Units in Package 3 | 9 |
| Package 3 Height | 15.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 6.446 kg |
Combined surge arrester type 1+2, Acti9 iPRD1 12.5r. 3-pole+N, nominal voltage (Un) 230/400V AC. Max. leakage current Imax 50kA, nominal leakage current In 20kA. Pluggable and exchangeable protection modules. Remote signaling contact for external fault reporting, red fault indicator on the device. Base can be rotated, so supply cable can be connected from below or above. Height 89.5 mm, height 74 mm, width 72 mm, weight 619 grams. Standards: IEC 61643-11: 2011 T1, T2 / EN 61643-11: 2012 Type 1 + Type 2. PU 1 piece, price unit 1 piece. Operating temperature -25°C to +60°C.