Further information for Schneider Electric A9F92172 circuit breaker 1p 1.6A
Complementary
Network frequency
50/60 Hz
[Ue] rated operational voltage
12...60 V AC 50/60 Hz; 100...133 V AC 50/60 Hz; 220...240 V AC 50/60 Hz; 12...60 V DC; 60...72 V DC
Magnetic tripping limit
3 x In +/- 20 %
Breaking capacity
100 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 100 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 25 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2; 20 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2; 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Ics] rated service breaking capacity
100 kA 100 % x Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 100 kA 100 % x Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 100 kA 100 % x Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 25 kA 100 % x Icu at 12...60 V DC conforming to EN/IEC 60947-2; 20 kA 100 % x Icu at 60...72 V DC conforming to EN/IEC 60947-2
Limitation class
3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-2
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Clip-on; Removable comb busbar installed
Mounting support
35 mm DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
Connection pitch
18 mm between devices
9 mm pitches
2
Height
85 mm
Width
18 mm
Depth
78.5 mm
Net weight
0.215 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper; Single terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible, copper; Single terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible with ferrule, copper; Single terminal (top or bottom) , for 1.0 cable(s) , flexible, copper or aluminium, with ring terminal and accessory
Wire stripping length
14 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Without
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 conforming to IEC 60529; IP40 in modular enclosure (Insulation class II) conforming to IEC 60529
Pollution degree
3 conforming to EN/IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Logistical informations
Country of origin
FR
Main
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
iC60L
Device application
Distribution
Poles description
1P
Number of protected poles
1
[In] rated current
1.6 A
Network type
DC; AC
Trip unit technology
Thermal-magnetic
Curve code
Z
Utilisation category
Category A conforming to EN/IEC 60947-2
Suitability for isolation
Yes conforming to EN/IEC 60947-2; Yes conforming to EN/IEC 60898-1
Standards
EN/IEC 60947-2; EN/IEC 60898-1
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.000 cm
Package 1 Width
7.500 cm
Package 1 Length
9.500 cm
Package 1 Weight
114.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
8.500 cm
Package 2 Width
10.000 cm
Package 2 Length
22.000 cm
Package 2 Weight
1.420 kg
Unit Type of Package 3
S03
Number of Units in Package 3
144
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
17.460 kg
Circuit breaker Acti 9 iC60L, 15kA (IEC/EN 60898-1), 100kA (IEC/EN 60947-2). 1-pole, nominal current 1.6A, Z characteristic, operating voltage (Ue) 220-240V AC, insulation voltage (Ui) 500V AC. Double connection terminal for cable and pin comb bar on the top and bottom of the device. Snap action for low-wear switching of the contacts. Insulation cover that moves with the device. Operation of the top hat rail fastening element on the front of the device for tool-free installation and easy access for the user. With mechanical front-side fault indication display (VisiTrip) to indicate trips due to overload or short circuit. Safe contact display (VisiSafe) of the circuit breaker, with a green display it is certain that there is no voltage on the outgoing side. Terminals IP20, moving insulation cover. Single connection terminal from above or below. Easy removal of the individual device with an installed phase rail, thanks to the fastening element accessible from the front. Can be combined with the residual current circuit breakers of the Acti 9 iID series, as well as the FI Block Vigi iC60. Additional auxiliary modules that can be connected in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. Color RAL 9003. The iC60L circuit breaker meets the following standards - IEC/EN 60898-1 (up to 40A) and IEC/EN 60947-2. This series is also VDE certified!