Further information for Schneider Electric A9F04106 Circuit Breaker 1p C 6A
Complementary
Network frequency
50/60 Hz
[Ue] rated operational voltage
12...60 V AC 50/60 Hz; 100...133 V AC 50/60 Hz; 220...240 V AC 50/60 Hz; 12...60 V DC; 60...72 V DC
Magnetic tripping limit
8 x In +/- 20 %
Breaking capacity
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2; 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2; 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Ics] rated service breaking capacity
27 kA 75 % x Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 75 % x Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 7.5 kA 75 % x Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 100 % x Icu at 12...60 V DC conforming to EN/IEC 60947-2; 10 kA 100 % x Icu at 60...72 V DC conforming to EN/IEC 60947-2
Limitation class
3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-2
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Clip-on; Removable comb busbar installed
Mounting support
35 mm DIN rail
Connection pitch
18 mm between devices
9 mm pitches
2
Height
91 mm
Width
18 mm
Depth
78.5 mm
Net weight
0.125 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Double terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper; Double terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible, copper; Double terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible with ferrule, copper; Double terminal (top or bottom) , for 1.0 cable(s) , flexible, copper or aluminium, with ring terminal and accessory
Wire stripping length
14 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Without
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 conforming to IEC 60529; IP40 in modular enclosure (Insulation class II) conforming to IEC 60529
Pollution degree
3 conforming to EN/IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Logistical informations
Country of origin
IN
Main
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Device application
Distribution
Poles description
1P
Number of protected poles
1
[In] rated current
6 A
Network type
AC; DC
Trip unit technology
Thermal-magnetic
Curve code
C
Utilisation category
Category A conforming to EN/IEC 60947-2
Suitability for isolation
Yes conforming to EN/IEC 60898-1; Yes conforming to EN/IEC 60947-2
Standards
EN/IEC 60947-2; EN/IEC 60898-1
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
1.800 cm
Package 1 Width
7.200 cm
Package 1 Length
8.900 cm
Package 1 Weight
112.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
8.900 cm
Package 2 Width
10.000 cm
Package 2 Length
23.100 cm
Package 2 Weight
1.480 kg
Unit Type of Package 3
S03
Number of Units in Package 3
132
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
16.980 kg
Circuit breaker Acti 9 iC60N, 6kA (IEC/EN 60898-1), 10kA (IEC/EN 60947-2). 1-pole, nominal current 6A, C characteristic, operating voltage (Ue) 220-240V AC, insulation voltage (Ui) 500V AC. Double connection terminal for cable and pin comb bar on the top and bottom of the device. Snap action for low-wear switching of the contacts. Moving insulation cover. Operation of the top hat rail fastening element on the front of the device for tool-free installation and easy access for the user. With mechanical front-side fault indication display (VisiTrip) to indicate trips due to overload or short circuit. Safe contact display (VisiSafe) of the circuit breaker, green display ensures that there is no voltage on the output side. Terminals IP20, moving insulation cover. Double connection terminal from above or below. Easy removal of the individual device with the phase rail installed, thanks to the fastening element accessible from the front. Technology of the trip unit - thermomagnetic. Can be combined with the residual current circuit breakers of the Acti 9 iID series, as well as the FI Block Vigi iC60. Additional auxiliary modules that can be connected in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. Color RAL 9003. The iC60N circuit breaker meets the following standards - IEC/EN 60898-1 and IEC/EN 60947-2. This series is also VDE certified!