Schneider Electric A9F04106, EAN: 3606480440335

Schneider Electric A9F04106 Circuit Breaker 1p C 6A

Installation > Modular devices / equipment installation > Circuit breaker

Schneider Electric A9F04106 Circuit Breaker 1p C 6A

Lieske Part No. 345085
Mfg Part No A9F04106
EAN-Code 3606480440335
Manufacturer Schneider Electric
Here only 33,20 EUR
39,51 EUR incl. VAT

Further information for Schneider Electric A9F04106 Circuit Breaker 1p C 6A

Complementary
Network frequency50/60 Hz
[Ue] rated operational voltage12...60 V AC 50/60 Hz; 100...133 V AC 50/60 Hz; 220...240 V AC 50/60 Hz; 12...60 V DC; 60...72 V DC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2; 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2; 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Ics] rated service breaking capacity27 kA 75 % x Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 75 % x Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 7.5 kA 75 % x Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 100 % x Icu at 12...60 V DC conforming to EN/IEC 60947-2; 10 kA 100 % x Icu at 60...72 V DC conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
Control typeToggle
Local signallingTrip indicator
Mounting modeClip-on; Removable comb busbar installed
Mounting support35 mm DIN rail
Connection pitch18 mm between devices
9 mm pitches2
Height91 mm
Width18 mm
Depth78.5 mm
Net weight0.125 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Connections - terminalsDouble terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper; Double terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible, copper; Double terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible with ferrule, copper; Double terminal (top or bottom) , for 1.0 cable(s) , flexible, copper or aluminium, with ring terminal and accessory
Wire stripping length14 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionWithout
Contact position indicatorYes
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60529; IP40 in modular enclosure (Insulation class II) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-35…70 °C
Ambient air temperature for storage-40…85 °C
Logistical informations
Country of originIN
Main
RangeActi9
Product nameActi9 iC60
Product or component typeMiniature circuit-breaker
Device short nameIC60N
Device applicationDistribution
Poles description1P
Number of protected poles1
[In] rated current6 A
Network typeAC; DC
Trip unit technologyThermal-magnetic
Curve codeC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Suitability for isolationYes conforming to EN/IEC 60898-1; Yes conforming to EN/IEC 60947-2
StandardsEN/IEC 60947-2; EN/IEC 60898-1
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height1.800 cm
Package 1 Width7.200 cm
Package 1 Length8.900 cm
Package 1 Weight112.000 g
Unit Type of Package 2BB1
Number of Units in Package 212
Package 2 Height8.900 cm
Package 2 Width10.000 cm
Package 2 Length23.100 cm
Package 2 Weight1.480 kg
Unit Type of Package 3S03
Number of Units in Package 3132
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight16.980 kg
Circuit breaker Acti 9 iC60N, 6kA (IEC/EN 60898-1), 10kA (IEC/EN 60947-2). 1-pole, nominal current 6A, C characteristic, operating voltage (Ue) 220-240V AC, insulation voltage (Ui) 500V AC. Double connection terminal for cable and pin comb bar on the top and bottom of the device. Snap action for low-wear switching of the contacts. Moving insulation cover. Operation of the top hat rail fastening element on the front of the device for tool-free installation and easy access for the user. With mechanical front-side fault indication display (VisiTrip) to indicate trips due to overload or short circuit. Safe contact display (VisiSafe) of the circuit breaker, green display ensures that there is no voltage on the output side. Terminals IP20, moving insulation cover. Double connection terminal from above or below. Easy removal of the individual device with the phase rail installed, thanks to the fastening element accessible from the front. Technology of the trip unit - thermomagnetic. Can be combined with the residual current circuit breakers of the Acti 9 iID series, as well as the FI Block Vigi iC60. Additional auxiliary modules that can be connected in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. Color RAL 9003. The iC60N circuit breaker meets the following standards - IEC/EN 60898-1 and IEC/EN 60947-2. This series is also VDE certified!
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/345085
qrcode für Schneider Electric A9F04106 Circuit Breaker 1p C 6A