Additional features
Network frequency50/60 Hz
[Ue] Operational rated voltage12 - 60 V AC 50/60 Hz; 100 - 133 V AC 50/60 Hz; 220 - 240 V AC 50/60 Hz; 12 - 60 V DC; 60 - 72 V DC
Magnetic trip threshold4 x inch +/-20 %
Breaking capacity36 kA Icu at 12 - 60 V AC 50/60 Hz complies with EN/IEC 60947-2; 20 kA Icu at 100 - 133 V AC 50/60 Hz complies with EN/IEC 60947-2; 10 kA Icu at 220 - 240 V AC 50/60 Hz complies with EN/IEC 60947-2; 15 kA Icu at 12 - 60 V DC complies with EN/IEC 60947-2; 10 kA Icu at 60 - 72 V DC complies with EN/IEC 60947-2; 6000 A Icn at 230 V AC 50/60 Hz complies with EN/IEC 60898-1
Rated switching-off capacity Ics27 kA 75 % x Icu at 12 - 60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 75 % x Icu at 100 - 133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 7.5 kA 75 % x Icu at 220 - 240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 100 % x Icu at 12 - 60 V DC conforming to EN/IEC 60947-2; 10 kA 100 % x Icu at 60 - 72 V DC conforming to EN/IEC 60947-2
Limiting class3 corresponds to EN/IEC 60898-1
[Ui] Rated insulation voltage500 V AC 50/60 Hz corresponds to EN/IEC 60947-2
[Uimp] Rated impulse voltage withstand6 kV corresponds to EN/IEC 60947-2
Control typeToggle switch
Local signallingtrip indicator
Mounting modePlug-on; Removable comb rail installed
Mounting bracket35 mm DIN rail
Terminal pitch18 mm between devices
9-mm pitch2
Height91 mm
Width18 mm
Depth78,5 mm
Product weight0,125 kg
ColourWhite
Mechanical life20000 cycles
Electrical lifetime10000 cycles
Connections - terminalsDouble terminal (top or bottom), for 1 cable(s), 1…25 mm², solid, copper; Double terminal (top or bottom), for 1 cable(s), 1…16 mm², stranded, copper; Double terminal (top or bottom), for 1 cable(s), 1…16 mm², stranded with ferrule, copper; Double terminal (top or bottom), for 1.0 cable(s), stranded, copper or aluminium, with ring terminal and accessory
Wire stripping length14 mm for top or bottom connection
[M] tightening torque2 Nm top or bottom
Earth fault protectionNone
Contact position indicatorJa
Contractual warranty
Warranty (in months)18
Main features
Product seriesActi9
Product nameActi9 iC60
Product or component typeMiniature circuit breaker (MCB)
Device short nameiC60N
Device applicationDistribution
Pole description1P
Number of protected poles1
[In] Rated current25 A
Type of networkDC; AC
Trigger technologyThermal-magnetic
Cam discB
Application categoryCategory A corresponds to EN/IEC 60947-2
Suitability for insulationYes complies with EN/IEC 60898-1; Yes complies with EN/IEC 60947-2
StandardsEN/IEC 60947-2; EN/IEC 60898-1
Mounting
Degree of protection (IP)IP20 corresponds to IEC 60529; IP40 in modular enclosure (Class II insulation) corresponds to IEC 60529
Pollution degree3 corresponds to EN/IEC 60947-2
Over voltage categoryIV
Drip-proof2 corresponds to IEC 60068-1
Relative humidity95 % at 55 °C
Operating ambient temperature-35…70 °C
Ambient temperature during storage-40…85 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height1,700 cm
VPE 1 width7,400 cm
VPE 1 length9,100 cm
Packaging weight (Lbs)121,000 g
VPE 2 typeBB1
VPE 2 quantity12
VPE 2 height8,500 cm
VPE 2 width9,800 cm
VPE 2 length22,000 cm
VPE 2 weight1,507 kg
VPE 3 typeS03
VPE 3 quantity132
VPE 3 height30 cm
VPE 3 width30 cm
VPE 3 length40 cm
VPE 3 weight17,064 kg
The circuit breaker A9F03125 from the Acti9 series by Schneider Electric is a 1-pole switch with a rated current of 25 A and B characteristic. It is designed for distribution and protection of electrical circuits against overload and short circuit in installations with alternating and direct voltage. The device is designed for operating voltages of 220–240 V AC 50/60 Hz and complies with standards EN/IEC 60947-2 and EN/IEC 60898-1. The tripping technology is thermomagnetic, with the magnetic tripping threshold set at 4 times the rated current. The protection rating is IP20 at the terminals and IP40 in the modular housing, enabling installation in indoor environments with limited access to moving parts. The insulation voltage is 500 V AC, and the impulse voltage withstand is 6 kV. The device is designed for an ambient temperature of -35 °C to 70 °C during operation and -40 °C to 85 °C during storage.

Applications

The switch is designed for use in electrical distribution systems, particularly in residential and commercial buildings as well as industrial installations. It is suitable for protection functions in circuits with an operating voltage of 220–240 V AC. The usage category A according to EN/IEC 60947-2 allows use in installations not intended for the protection of electrical devices. The limitation class 3 according to EN/IEC 60898-1 indicates the ability to limit short-circuit current.

Functions and Equipment in Detail

The device features double terminals at the top and bottom, suitable for connecting solid copper conductors from 1 to 25 mm² and flexible copper conductors from 1 to 16 mm². Connections can also be made with flexible conductors up to 16 mm² with wire end ferrules, or copper or aluminium conductors with ring terminals. The wire stripping length is 14 mm, and the tightening torque is 2 Nm. The contact position indicator (VisiSafe) shows green when the outgoing side is de-energized. The tripping indicator (VisiTrip) mechanically signals tripping due to overload or short circuit. Mounting is tool-free on a 35 mm DIN rail, with the mounting element operated from the front. The connection pitch is 18 mm, height 91 mm, width 18 mm, and depth 78.5 mm. The device has a mechanical life of 20,000 cycles and an electrical life of 10,000 cycles.

Technology Explained Simply

The thermomagnetic tripping technology combines a thermal and a magnetic tripping mechanism. The thermal part responds to sustained overloads, while the magnetic part protects against sudden short circuits. The B characteristic means that the switch trips after approximately 1 second at 3 times the rated current and within 0.1 seconds at 5 times the rated current. The breaking capacity is 10 kA at 220–240 V AC, ensuring the ability to interrupt short-circuit currents in typical distribution systems. The insulation cover moves with the contacts to ensure safe disconnection.

Compatibility and Accessories

The switch is compatible with RCD circuit breakers from the Acti 9 iID series and the Vigi iC60 RCD module. Additionally, auxiliary modules such as current release, undervoltage release, auxiliary contacts, and reclosing devices can be used. Suitable accessories include, for example, the undervoltage release A9A26960, auxiliary contact A9A26919, phase bar modules such as A9XAH657 and A9XPH157, as well as filler and spacing pieces such as A9A27062. Combining the switch with these modules extends functionality for specific applications.

Mounting and Installation

Mounting is done on a 35 mm DIN rail, with the device secured tool-free from the front. Removal is also tool-free, especially when using a phase bar. Connections can be made at the top and bottom, enabling flexible integration into distribution enclosures. The device colour is white (RAL 9003). Pollution degree class 3 and overvoltage category IV are suitable for use in electrical installations with increased pollution risk and near voltage sources.

Advantages in Operation

Tool-free mounting and removal simplify installation and maintenance. The visual indicators (VisiSafe and VisiTrip) allow for quick status checks. The double terminal offers flexibility in wiring. The high service life and reliability of the thermomagnetic tripping technology ensure stable operation. Compatibility with additional modules extends functionality without requiring additional switchgear cabinets.

The device is designed for use in electrical distribution systems requiring safe and reliable power supply. Compliance with standards and VDE certification guarantee adherence to safety requirements.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/407030
qrcode für Schneider Electric A9F03125 Circuit Breaker 1p B 25A