Schneider Electric A9D33616, EAN: 3606480472152

Schneider Electric A9D33616 residual current circuit breaker 1p+N 16A

Installation > Modular devices / equipment installation > RCD

Schneider Electric A9D33616 residual current circuit breaker 1p+N 16A

Lieske Part No. 611326
Mfg Part No A9D33616
EAN-Code 3606480472152
Manufacturer Schneider Electric
Here only 204,25 EUR
243,06 EUR incl. VAT

Further information for Schneider Electric A9D33616 residual current circuit breaker 1p+N 16A

Complementary
Device location in systemOutgoer
[Ue] rated operational voltage230...240 V AC 50 Hz
Magnetic tripping limit5...10 x In
Residual current tripping technologyVoltage independent
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType A-SI (Super Immunised)
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage440 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Connections - terminalsSingle terminal top or bottom 1…16 mm² rigid; Single terminal top or bottom 1…10 mm² flexible; Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
Contact position indicatorYes
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 61009-2-1
Product certificationsVDE; RCM
IP degree of protectionIP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…85 °C
Logistical informations
Country of originES
Main
RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameiDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current16 A
Network typeAC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Suitability for isolationYes conforming to EN/IEC 60947-2
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.000 cm
Package 1 Width4.000 cm
Package 1 Length9.800 cm
Package 1 Weight212.000 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight12.561 kg
Residual current circuit breaker with overcurrent protection (FI/LS) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole+N, nominal current 16A, C characteristic, earth fault sensitivity 30mA, earth fault protection class type A SI, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Guarantees comprehensive protection of final circuits against overcurrents and fault currents. Switching and disconnecting circuits. Snap action for low-wear switching of the contacts. Mechanically separated red display when the circuit breaker is tripped or when it is tripped by a residual current. Clear switch position display by green marking on the device's switch knob. Test button for regular function testing. The SI (superimmunized) version is designed to maintain operational continuity in systems in which high transient leakage currents can occur due to operational reasons or external influences. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt release (iMX), auxiliary switch for status reporting (iOF), fault reporting switch (iSD). Tool-free installation on the left side of the device. Color RAL 9003. The FI/LS IDPN N Vigi meets the following standards - IEC/EN 61009 and IEC/EN 60947-2. This series is also VDE certified!
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/611326
qrcode für Schneider Electric A9D33616 residual current circuit breaker 1p+N 16A