Further information for Schneider Electric A9D33610 residual current circuit breaker 1p+N 10A
Complementary
Device location in system
Outgoer
[Ue] rated operational voltage
230...240 V AC 50 Hz
Magnetic tripping limit
5...10 x In
Residual current tripping technology
Voltage independent
Earth-leakage protection time delay
Instantaneous
Earth-leakage protection class
Type A-SI (Super Immunised)
Breaking capacity
6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity
6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacity
Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class
3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage
440 V AC 50 Hz
[Uimp] rated impulse withstand voltage
4 kV
Control type
Toggle
Local signalling
ON, OFF, fault trip
Mounting mode
Clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
Connection pitch
9 mm between phase and neutral
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
73 mm
Net weight
125 g
Colour
White
Mechanical durability
20000 cycles
Electrical durability
20000 cycles
Locking options description
Padlocking device
Connections - terminals
Single terminal top or bottom 1…16 mm² rigid; Single terminal top or bottom 1…10 mm² flexible; Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length
15 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Integrated
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
Standards
EN/IEC 61009-2-1
Product certifications
VDE; RCM
IP degree of protection
IP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529
Pollution degree
3
Overvoltage category
III conforming to IEC 60364
Electromagnetic compatibility
8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-25…60 °C
Ambient air temperature for storage
-40…85 °C
Logistical informations
Country of origin
ES
Main
Range
Acti9
Product name
Acti9 iDPN Vigi
Product or component type
Residual current breaker with overcurrent protection (RCBO)
Device short name
iDPN N Vigi
Device application
Distribution
Poles description
1P + N
Number of protected poles
1
Neutral position
Left
[In] rated current
10 A
Network type
AC
Network frequency
50 Hz
Trip unit technology
Thermal-magnetic
Curve code
C
Earth-leakage sensitivity
30 mA
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.000 cm
Package 1 Width
8.500 cm
Package 1 Length
10.000 cm
Package 1 Weight
211.000 g
Unit Type of Package 2
S03
Number of Units in Package 2
54
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
11.860 kg
Residual current circuit breaker with overcurrent protection (FI/LS) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole+N, nominal current 10A, C characteristic, earth fault sensitivity 30mA, earth fault protection class type A SI, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Guarantees comprehensive protection of final circuits against overcurrents and fault currents. Switching and disconnecting circuits. Snap action for low-wear switching of the contacts. Mechanically separated red display when the circuit breaker is tripped or when it is tripped by a fault current. Clear switch position display through green marking on the device's switch knob. Test button for regular function testing. The SI (superimmunized) version is designed to maintain operational continuity in systems in which high transient leakage currents can occur due to operational reasons or external influences. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt release (iMX), auxiliary switch for status reporting (iOF), fault reporting switch (iSD). Tool-free installation on the left side of the device. Color RAL 9003. The FI/LS IDPN N Vigi meets the following standards - IEC/EN 61009 and IEC/EN 60947-2. This series is also VDE certified!