Schneider Electric A9C15419, EAN: 3606480097911

Schneider Electric A9C15419 heating contactor 24-230 V AC

Installation > Modular devices / equipment installation > Heating contactor

Schneider Electric A9C15419 heating contactor 24-230 V AC

Lieske Part No. 612679
Mfg Part No A9C15419
EAN-Code 3606480097911
Manufacturer Schneider Electric
Here only 135,85 EUR
161,66 EUR incl. VAT

Further information for Schneider Electric A9C15419 heating contactor 24-230 V AC

Complementary
Type of settingTime delay configuration
Time delay range2 s...10 min; 2 s...10 h; 6...60 s; 1...10 s; 6 s...1 h
Maximum output current0.2 A holding; 3 A inrush
Hold-in power consumption in VA5 VA
Mounting modeFixed, on the left of TL or CT
Mounting supportDIN rail
9 mm pitches2
Height81 mm
Width18 mm
Depth60 mm
ColourWhite
Overvoltage categoryIII
[Uimp] rated impulse withstand voltage4 kV
[Ui] rated insulation voltage440 V
StandardsEN/IEC 60669-2-2
Connections - terminalsOutput connection: yellow clips ; Input connection: tunnel type terminals 2 cable(s) 2.5 mm² flexible; Input connection: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Wire stripping length9 mm
Tightening torque0.8 N.m
Range compatibilityActi9 iCT; Acti9 iTL
Market segmentSmall commercial; Residential
Compatibility codeIATEt
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…50 °C
Ambient air temperature for storage40…80 °C
Logistical informations
Country of originFR
Main
RangeActi9
Product or component typeTime delay auxiliary
Device short nameiATEt
[Uc] control circuit voltage24...110 V DC impulse; 24...240 V AC 50/60 Hz maintained
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.000 cm
Package 1 Width2.300 cm
Package 1 Length9.000 cm
Package 1 Weight86.000 g
Unit Type of Package 2S03
Number of Units in Package 2108
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.789 kg
Time relay Acti 9 time delay iATEt. Operating voltage (Ue) 24-230V AC / 24-110V DC. Time-delayed control of the contactors iCT and iTL. Depending on the wiring, up to four functions can be implemented. 1 function for iTL. 4 functions for iCT.