Range compatibilityActi9 iC60; Acti9 iID double terminals residual current circuit breaker (RCCB)
Operating modeDaisy chain up to 100 devices
[Ui] rated insulation voltage500 V
[Uimp] rated impulse withstand voltage4 kV
Mounting modeClip-on
Mounting locationLeft side of circuit-breaker
Mounting supportDIN rail
Comb busbar and distribution block compatibilityBottom: YES
Height86 mm
Width9 mm
Depth73 mm
Net weight32 g
ColourWhite
Connections - terminalsScrew clamp terminal (top): 1 cable(s) 1…4 mm² - rigid; Screw clamp terminal (top): 1 cable(s) 0.5…2.5 mm² - flexible; Screw clamp terminal (top): 2 cable(s) 2.5 mm² - rigid; Screw clamp terminal (top): 2 cable(s) 1.5 mm² - flexible with ferrule
Wire stripping length10 mm
Tightening torque1 N.m top
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20
Pollution degree3
Tropicalisation2
Relative humidity95 % at 55 °C
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Logistical informations
Country of originIN
Main
range of productActi9
Product or component typeOC contact
Device short nameiOF
Signal contacts composition1 C/O
[In] rated current2…100 mA at 24...240 V, AC 50/60 Hz; 2…100 mA at 24 V, DC; 2…100 mA at 48 V, DC; 2…100 mA at 60 V, DC; 2…100 mA at 130 V, DC; 2…100 mA at 220 V, DC
9 mm pitches1
StandardsEN/IEC 60947-5-1; EN/IEC 60947-5-4; GB/T 14048.5; GB/T 14048.17
Product certificationsUKCA; CE
Quality labelsCCC; EAC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.000 cm
Package 1 Width7.800 cm
Package 1 Length9.300 cm
Package 1 Weight42.000 g
Unit Type of Package 2BB1
Number of Units in Package 212
Package 2 Height8.200 cm
Package 2 Width10.000 cm
Package 2 Length26.500 cm
Package 2 Weight582.000 g
Unit Type of Package 3S03
Number of Units in Package 3120
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight6.608 kg
The iOF auxiliary switch from the Acti9 product range by Schneider Electric is an electrical accessory for indicating the operating position of a power switch. It functions as a changeover contact, signaling whether the main device is in the OPEN or CLOSED position, thereby enabling external monitoring or control. The device is intended for use in various application areas, including small commercial enterprises, buildings, critical infrastructure, healthcare, industry, and data centers. Compatibility is limited to the Acti9 series iC60 and iID double-pole residual current circuit breakers (RCCB), with the iOF being mounted on the left side of the power switch. Installation is carried out on a DIN rail, with the device width corresponding to a 9 mm pitch. The housing color is white (RAL 9003), and the dimensions are 9 mm (width) × 86 mm (height) × 73 mm (depth). The product weight is 32 g.

Applications

The iOF auxiliary switch is designed for installations where visual or electronic feedback on the state of a power switch is required. This includes, for example, monitoring of fuse switches in industrial plants, integration into building management systems, or use in critical infrastructures where the reliability of power supply is of high importance. Application in data centers enables remote monitoring of switching operations to detect failures early. The operating temperature ranges from -25 °C to +70 °C, allowing use in a wide variety of environments. Storage is possible at temperatures from -40 °C to +85 °C.

Functions and Equipment in Detail

The iOF features a changeover contact that functions as a make/break contact. The signal contacts are designed such that they close when the main switch is open and open when the main switch is closed. The rated current ranges from 2 mA to 100 mA, with voltage ranges including 24–240 V AC (50/60 Hz) and 24, 48, 60, 130, and 220 V DC. The rated insulation voltage (Ui) is 500 V, and the rated impulse voltage withstand (Uimp) is 4 kV. The protection class IP20 protects against finger contact and solid foreign objects, but not against splashing water. Pollution degree 3 and drip-proof treatment class 2 indicate use in indoor environments where no high pollution or humidity loads occur.

Technology Explained Simply

The iOF auxiliary switch operates as a mechanically coupled contact that transmits the position of the main power switch. The screw terminals on the top allow connection to cables of various cross-sections: for rigid copper cables from 1 to 4 mm², for flexible copper cables from 0.5 to 2.5 mm², as well as for two rigid cables with 2.5 mm² or two flexible cables with 1.5 mm², the latter requiring wire end ferrules. The wire stripping length is 10 mm, and the tightening torque for the screw terminals is 1 Nm. Chaining up to 100 devices enables a serial arrangement for larger installations. Compliance with standards EN/IEC 60947-5-1 and EN/IEC 60947-5-4, along with certifications CE, UKCA, CCC, and EAC, guarantees conformity with European and international safety standards.

Compatibility and Accessories

The iOF is specifically designed for use with Acti9 switching devices iC60 and iID double-pole residual current circuit breakers (RCCB). Mounting is performed on the left side of the main device, using the DIN rail as the mounting system. Compatibility with comb rails and distribution blocks is provided below. As accessories, various power switches and residual current circuit breakers from the Acti9 series are available, including models such as A9F03106, A9Z21463, or A9S65363, which can be combined with the iOF. The devices are designed for use in electrical distribution systems, with the iOF component transmitting the status information.

Mounting and Installation

Mounting is done by clipping the auxiliary switch onto the DIN rail on the left side of the power switch. The screw terminals on the top allow for a secure connection to the connecting cables. Cable cross-sections and types are clearly defined to ensure a safe and reliable connection. Installation should be carried out by qualified electrical specialists, as the connection is made to the electrical system. The operating temperature range of -25 °C to +70 °C requires consideration of ambient conditions, especially in industrial or outdoor installations.

Advantages in Operation

The iOF provides reliable feedback on the state of the power switch, simplifying maintenance and diagnosis of electrical systems. The ability to chain up to 100 devices enables a scalable solution for larger installations. Compliance with standards EN/IEC 60947-5-1 and EN/IEC 60947-5-4, along with CE and UKCA certifications, ensures safety and reliability. The compact design and DIN rail mounting facilitate integration into existing switchgear. The operating temperature range and IP20 protection class make the device suitable for indoor use, where no high mechanical or climatic loads occur.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/681406
qrcode für Schneider Electric A9A26915 Auxiliary Switch for IC60/LI