Further information for Schneider Electric 21110 motor protection switch 3p 14A
Complementary
Network frequency
50/60 Hz
[Ue] rated operational voltage
440 V AC 50/60 Hz; 230...240 V AC 50/60 Hz; 400...415 V AC 50/60 Hz; 500 V AC 50/60 Hz; 690 V AC 50/60 Hz
Magnetic tripping limit
12 x In
[Ics] rated service breaking capacity
2.25 kA conforming to EN/IEC 60947-2 - 690 V AC 50/60 Hz; 4 kA conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz; 4.5 kA conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz; 7.5 kA conforming to EN/IEC 60947-2 - 400...415 V AC 50/60 Hz
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Control type
Toggle; Manual tripping test
Local signalling
ON/OFF indication
Mounting mode
Clip-on
Mounting support
35 mm symmetrical DIN rail
9 mm pitches
5
Height
89 mm
Width
45 mm
Depth
70 mm
Net weight
0.26 kg
Electrical durability
AC-3: 100000 cycles AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400...415 V AC 50/60 Hz conforming to EN/IEC 60947-2; 3 kA Icu at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2; 6 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2; 8 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
AC-3 conforming to IEC 60947-2
Suitability for isolation
Yes conforming to IEC 60947-2
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.5 cm
Package 1 Width
4.7 cm
Package 1 Length
9.2 cm
Package 1 Weight
283.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
24
Package 2 Height
15 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
7.102 kg
Circuit breaker Acti 9 C120N, 10kA (IEC/EN 60898-1), 10kA (IEC/EN 60947-2). 4-pole, nominal current 80A, B characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 500V AC. Protecting circuits against short-circuit currents and overload currents. Terminals IP20. Fully open contacts are indicated by the OFF marking on the switch knob, so that work on the downstream system part can be carried out with due safety. Power supply from above and below. Snap action for low-wear switching of the contacts. Technology of the trip unit - thermomagnetic. Can be combined with the FI Block Vigi for C120. Additional auxiliary modules (optional) that can be connected in series - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. Color RAL 9003. The C120N circuit breaker meets the following standards - IEC/EN 60898-1 and IEC/EN 60947-2. This series is also VDE certified.