Further information for Schneider Electric 18893 load isolator 4-pole 63A
Complementary
[Ie] rated operational current
63 A at 500 V AC 50/60 Hz
[Ue] rated operational voltage
500 V AC 50/60 Hz
[Icm] rated short-circuit making capacity
2 kA switch-disconnector alone
[Icw] rated short-time withstand current
1.5 kA during 50 ms conforming to IEC 60947-3
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-3
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-3
Control type
Manual tripping test; Toggle
Local signalling
ON/OFF indication; Trip indicator
Mounting mode
Fixed
Mounting support
35 mm symmetrical DIN rail
9 mm pitches
12
Height
103 mm
Width
108 mm
Depth
81 mm
Net weight
0.96 kg
Colour
Black
Mechanical durability
20000 cycles
Electrical durability
Category A (except AC20, DC20): 1500 cycles AC 50/60 Hz conforming to IEC 60947-3
Provision for padlocking
Padlockable
Locking options description
Integrated padlocking
Connections - terminals
Tunnel type terminals (top or bottom) 1…35 mm² flexible; Tunnel type terminals (top or bottom) 1.5…50 mm² rigid
Wire stripping length
Power circuit: 20 mm for top or bottom connection
Tightening torque
Power circuit: 3.5 N.m top or bottom
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
Standards
EN 60947-3; IEC 60947-3
IP degree of protection
IP20 conforming to IEC 60529; IP40 conforming to IEC 60529
IK degree of protection
IK05
Pollution degree
3 conforming to IEC 60947-3
Tropicalisation
2 conforming to IEC 60068-1
Ambient air temperature for operation
-10…60 °C
Ambient air temperature for storage
-40…70 °C
Logistical informations
Country of origin
FR
Main
Range
Acti9
Product name
Acti9 NG125NA
Product or component type
Switch disconnector
Device short name
NG125NA
Device application
Distribution; Making and breaking under load
Poles description
3P + N
Neutral position
Left
Number of protected poles
4
Utilisation category
AC-22A conforming to IEC 60947-3; AC-22B conforming to IEC 60947-3; AC-23B conforming to IEC 60947-3
Suitability for isolation
Yes conforming to IEC 60947-3
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.6 cm
Package 1 Width
12.4 cm
Package 1 Length
15.5 cm
Package 1 Weight
1.043 kg
Unit Type of Package 2
S03
Number of Units in Package 2
12
Package 2 Height
30 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
13.003 kg
Acti 9 NG125LMA circuit breaker, 50kA (IEC/EN 60947-2). 3-pole, nominal current 16A, MA characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 690V AC. Protection of the circuit against short-circuit currents. Protection of the circuit against overload currents. Tripping is indicated by the middle position of the switch knob and by a red, mechanical display on the front of the device. Test button for checking the tripping mechanism. Power supply from above or below. Snap action for low-wear switching of the contacts. Technology of the tripping unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. The NG125LMA circuit breaker meets the following standards - IEC/EN 60947-2.