Schneider Electric 18872, EAN: 3303430188728

Schneider Electric 18872 motor protection switch 2-pole 16A

Industrial Material > Control devices / Pilot devices > Motor protection switch

Schneider Electric 18872 motor protection switch 2-pole 16A

Lieske Part No. 471303
Mfg Part No 18872
EAN-Code 3303430188728
Manufacturer Schneider Electric
Here only 214,70 EUR
255,49 EUR incl. VAT

Further information for Schneider Electric 18872 motor protection switch 2-pole 16A

Complementary
Network frequency50/60 Hz
[Ue] rated operational voltage380...415 V AC 50/60 Hz; 500 V AC 50/60 Hz; 220...240 V AC 50/60 Hz; 440 V AC 50/60 Hz
Magnetic tripping limit12 x In
[Ics] rated service breaking capacity75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz; 37.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz; 30 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz; 11.25 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Control typeManual tripping test; Toggle
Local signallingON/OFF indication; Trip indicator
Mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
9 mm pitches6
Height103 mm
Depth81 mm
Width54 mm
Net weight0.48 kg
Mechanical durability20000 cycles
Electrical durability10000 cycles
Provision for padlockingPadlockable
Locking options descriptionIntegrated padlocking
Connections - terminalsTunnel type terminals1.5…50 mm² rigid; Tunnel type terminals1…35 mm² flexible
Wire stripping length20 mm
Tightening torque3.5 N.m
Earth-leakage protectionSeparate block
Contact position indicatorYes
Comb busbar and distribution block compatibilityYES
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK05 conforming to EN/IEC 62262
Pollution degree3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-30…70 °C
Ambient air temperature for storage-40…70 °C
Main
RangeActi9
Product nameActi9 NG125LMA
Product or component typeMiniature circuit-breaker
Device short nameNG125LMA
Device applicationMotor
Poles description2P
Number of protected poles2
[In] rated current16 A at 40 °C
Network typeAC
Trip unit technologyMagnetic
Curve codeMA
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 40 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2; 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
StandardsEN/IEC 60947-2
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.8 cm
Package 1 Width8.1 cm
Package 1 Length11 cm
Package 1 Weight472 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height9.1 cm
Package 2 Width11.9 cm
Package 2 Length36 cm
Package 2 Weight2.921 kg
Unit Type of Package 3S03
Number of Units in Package 336
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight18.013 kg
Acti 9 NG125L circuit breaker, 50kA (IEC/EN 60947-2). 4-pole, nominal current 32A, D characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 690V AC. Protection of the circuit against short-circuit currents. Protection of the circuit against overload currents. Tripping is indicated by the middle position of the switch knob and by a red, mechanical display on the front of the device. Test button for checking the tripping mechanism. Power supply from above or below. Snap action for low-wear switching of the contacts. Technology of the tripping unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. The NG125L circuit breaker meets the following standards - IEC/EN 60947-2.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/471303
qrcode für Schneider Electric 18872 motor protection switch 2-pole 16A