Further information for Schneider Electric 18612 power switch 1-pole 20A
Complementary
Network frequency
50/60 Hz
[Ue] rated operational voltage
380...415 V AC 50/60 Hz; 125 V DC;
Magnetic tripping limit
8 x In
[Ics] rated service breaking capacity
37.5 kA 75 % conforming to EN/IEC 60947-2 - 110...130 V AC 50/60 Hz; 18.75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz; 4.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz; 25 kA 100 % conforming to EN/IEC 60947-2 - 60 V DC; 25 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV conforming to EN/IEC 60947-2
Control type
Toggle; Manual tripping test
Local signalling
ON/OFF indication; Trip indicator
Mounting mode
Clip-on
Mounting position
Vertical
Mounting support
35 mm symmetrical DIN rail
9 mm pitches
3
Height
103 mm
Depth
81 mm
Width
27 mm
Net weight
0.24 kg
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Provision for padlocking
Padlockable
Locking options description
Integrated padlocking
Connections - terminals
Tunnel type terminals1.5…50 mm² rigid; Tunnel type terminals1…35 mm² flexible
Wire stripping length
20 mm
Tightening torque
3.5 N.m
Earth-leakage protection
Without
Contact position indicator
Comb busbar and distribution block compatibility
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 conforming to IEC 60529
IK degree of protection
IK05 conforming to EN/IEC 62262
Pollution degree
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-30…70 °C
Ambient air temperature for storage
-40…70 °C
Logistical informations
Country of origin
FR
Main
Range
Acti9
Product name
Acti9 NG125
Product or component type
Miniature circuit-breaker
Device short name
NG125N
Device application
Distribution
Poles description
1P
Number of protected poles
1
[In] rated current
20 A at 40 °C
Network type
DC; AC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
25 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 25 kA Icu at 12 V DC conforming to EN/IEC 60947-2; 50 kA Icu at 110...130 V AC 50/60 Hz conforming to EN/IEC 60947-2; 6 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2; 25 kA Icu at 125 V DC conforming to EN/IEC 60947-2; 20 kA Icu at
Utilisation category
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to IEC 60947-2
Standards
EN/IEC 60947-2
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3 cm
Package 1 Width
8 cm
Package 1 Length
11 cm
Package 1 Weight
244 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
9.3 cm
Package 2 Width
12.1 cm
Package 2 Length
36.2 cm
Package 2 Weight
3.018 kg
Unit Type of Package 3
S03
Number of Units in Package 3
72
Package 3 Height
30 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
18.574 kg
Circuit breaker Acti 9 C60PV-DC, 1.5kA (IEC/EN 60947-2). 2-pole, nominal current 16A, C characteristic, operating voltage (Ue) 800V DC, insulation voltage (Ui) 1000V DC. Short-circuit and overload protection. Snap action for low-wear switching of the contacts. Insulation cover moves with the device. Green stripe on the device's switch knob shows that the contacts are open. Additional auxiliary modules that can be connected in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release. Color RAL 9003. The C60PV-DC circuit breaker meets the following standards - IEC/EN 60947-2.