Further information for Schneider Electric 12237 RCD Switch 4P 40A
General
Number of poles
4-pole
Nominal current
40 A
Rated residual current
0,03 A
Rated voltage
400 V
Leakage current type
A
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
0,25 kA
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Construction size (in accordance with DIN 43880)
4
Width in number of modular spacings
4
Built-in depth
76 mm
Standards
VDE 0664 Part 11
Mounting method
DIN rail (REG)
Terminals for flexible conductors
up to 35 mm²
Selective protection
Additional equipment possible
Short-time delayed tripping
Terminal for fork rail
The residual current circuit breaker from Schneider Electric, type Merlin Gerin Multi 9, is a 4-pole switching device for electrical protection of consumers and installations. It is designed for use in installations where high protection against electric shock and fire hazard due to fault currents is required. The device complies with standard VDE 0664 part 11 and is rated for a nominal voltage of 400 V. With a nominal current of 40 A and a nominal residual current of 0.03 A (30 mA), it provides reliable protection against dangerous fault currents, particularly in installations with electronic devices that may generate harmonic currents or pulsating loads. The residual current type A enables detection of alternating and direct current fault currents, making it especially suitable for applications with electronic devices, such as computers or LED lighting.
Residual current circuit breaker are indispensable in electrical installations to immediately interrupt the power supply in case of insulation failure or contact between conductor and earth. This circuit breaker is designed for mounting on a DIN rail (REG), ensuring a standardized and secure installation in distribution boards. The size according to DIN 43880 is 4, corresponding to a width of 4 module units. The mounting depth of 76 mm must be considered when planning the dimensions of the distribution board. The protection rating IP20 means the device is protected against contact with fingers and against solid foreign objects up to 12.5 mm, but not against splashing water or dust – thus it is intended for indoor use.
Technology explained clearly
The switch features cage terminals suitable for flexible conductors up to 35 mm². These terminals allow for a secure and durable connection of the conductors, with the terminal for forked rail providing an additional mounting option. The short-circuit withstand capability is 10 kA, meaning the device can safely withstand short-term current surges up to this level without damage. The surge current withstand capability of 0.25 kA (250 A) protects the device against sudden, brief current peaks. The frequency is rated for 50/60 Hz, enabling use in European and international power networks. The device is not designed as a time-delayed type, meaning it trips immediately upon detection of a fault current, without delay.
Compatibility and accessories
Additional components such as auxiliary switches can be mounted on this residual current circuit breaker, enabling integration into control and monitoring systems. Combination with other devices from the Merlin Gerin Multi 9 series is possible, as the size and mounting method are standardized. The use of auxiliary switches allows, for example, remote monitoring of the switching state or integration into alarm or automation systems.
Mounting and installation
Mounting is done on a DIN rail, with the mounting depth of 76 mm and width of 4 module units to be considered when planning the dimensions of the distribution board. The cage terminals allow for easy and secure connection of the conductors. The terminal for forked rail offers an additional mounting option, particularly in distribution boards with corresponding fastening. Installation must comply with applicable regulations and standards, with correct polarity and adherence to electrical safety regulations being essential.
Advantages in operation
The switch provides reliable protection against electric shock and fire hazard due to fault currents. The rapid disconnection upon detection of a fault current minimizes the risk of damage to devices and persons. Compatibility with auxiliary switches allows for functional expansion, e.g. for remote monitoring. Use in combination with other devices from the Multi 9 series ensures uniform and secure installation in distribution boards. The device is tested as a demonstration unit, confirming its quality and reliability.
Applications
The residual current circuit breaker is suitable for use in residential and commercial buildings, office and industrial facilities, as well as in installations with electronic devices. It protects individuals who come into contact with electrical devices and prevents damage to electrical installations due to fault currents. Use in distribution boards with other protective and switching devices from the Multi 9 series is possible, ensuring uniform and secure installation.