| Complementary |
| Number of ways | 6 ways 2 L |
| Distribution type | L1 L2 |
| Poles configuration for 1 way | 1 x 2P |
| Connection pitch | 18 mm |
| Connector type | Tooth |
| Distance between way | 36 mm |
| Marking | L1 L2 |
| Insulation | Insulated |
| Device presentation | Uncuttable |
| [Ie] rated operational current | 100 A at 40 °C |
| [Ue] rated operational voltage | 277 V AC Ph/N; 480 V AC Ph/Ph |
| [Ui] rated insulation voltage | 690 V AC |
| [Uimp] rated impulse withstand voltage | 12 kV |
| Mounting location | Top on tunnel type terminals |
| 9 mm pitches | 24 |
| Width | 216 mm |
| Colour | Light grey (RAL 7035) |
| Range compatibility | Multi9 C60SP |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Fire resistance | 960 °C ( 30 s ) |
| Logistical informations |
| Country of origin | DE |
| Main |
| Range | Multi9 |
| Product or component type | Comb busbar |
| Mounting mode | Horizontal |
| Accessory / separate part category | Connection accessory |
| Lines description | 2L |
| Length in 18 mm modules | 12 |
| Standards | UL 1077; CSA C22.2 No 235; EN/IEC 61439-1 |
| Product certifications | CURus |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.300 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 21.500 cm |
| Package 1 Weight | 94.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 72 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.100 kg |
The Phase Bar Strip Multi 9 from Schneider Electric, type 10286, is a connection accessory for circuit breakers of the C60SP series, specifically designed for use in accordance with UL 1077. It serves as a
comb busbar for distributing supply voltage within an enclosure and enables direct power supply within the cage of the power switch. The busbar is designed for horizontal mounting and is secured on top of tunnel terminals. It is
insulated and available in Light Grey (RAL 7035), allowing it to blend visually into industrial enclosures.
Applications
The comb busbar is exclusively intended for C60SP circuit breakers compliant with UL 1077. It is used in enclosures where central power supply for multiple switches or auxiliary devices is required. The busbar generates voltage supply directly within the cage of the power switch, achieving a compact and efficient distribution. Compatibility with the interrupting capacity of C60SP switches and additional protective devices ensures safe and reliable operation.
Functions and Equipment in Detail
The busbar is 2-pole (L1, L2) and features a pole configuration of 1 x 2P per circuit. It is rated for an
operating voltage of 277 V AC (Ph/N) and 480 V AC (Ph/Ph), with an
insulation voltage rating of 690 V AC. The
rated impulse withstand voltage is 12 kV, making the busbar suitable for use in industrial environments with high electrical loads. The
rated operating current is 100 A at an ambient temperature of 40 °C, with the busbar designed for a maximum load of 63 A. Pole labeling is done with L1 and L2 to ensure clear identification.
Technology Explained Simply
The comb busbar is constructed in 12 mounting units (TE) with a connection pitch of 18 mm, corresponding to a total width of 216 mm. The spacing between poles is 36 mm, ensuring mechanical stability and electrical insulation. Connections are made via pins inserted into the tunnel terminals of the switches. The busbar is not cuttable to maintain electrical integrity and safety. Flame resistance is 960 °C for 30 seconds, supporting its use in fire alarm and safety systems.
Compatibility and Accessories
The phase bar is exclusively compatible with the Multi 9 C60SP product family. It can only be used with power switches of this series that comply with UL 1077. The busbar is not intended for other switch types or series. Mounting is horizontal, with the busbar placed on the tunnel terminals of the switches.
Mounting and Installation
Mounting is performed horizontally on the tunnel terminals of the C60SP switches. Supply lines must be connected to the power switch with the highest rated current to ensure safe power supply. The load on the branches must not exceed 80 % of the highest rated current. The busbar is not cuttable, so the specified length of 12 TE (216 mm) must be maintained. Mounting requires no additional tools, as the pins are directly inserted into the terminals.
Operational Advantages
The comb busbar enables compact and secure power distribution within the enclosure. Direct supply within the cage of the power switch reduces the number of required connections and minimizes error sources. High insulation strength and flame resistance increase operational safety. Compatibility with C60SP switches and associated protective devices ensures reliable performance in industrial installations. The busbar is designed for use in environments with high electrical loads and temperature stress, making it suitable for industrial and machine-building applications.