| General |
| Model | for mounting in rows, with cutout for outdoor climate unit 2 - 5 kW |
| Material | Housing frame: stainless steel 1.4301 (AISI 304), flat parts and base panels: aluminium, AlMg3, rain hood: aluminium |
| Surface protection | Powder-coated, UV-resistant pure polyester |
| Colour | RAL 7035 |
| Scope of delivery | Stackable, double-walled outdoor enclosure, cabinet frame with 25 mm system mounting holes in top and bottom frames as well as vertical profiles with 2 mounting planes, front door with door latch, swing handle and profile half-cylinder, lock BJ20027, rear panel, rain hood, base with screwed flange plates and screwed front and rear covers |
| Width | 800 mm |
| Height | 1.800 mm |
| Depth | 800 mm |
| Dimensions | Total height: 1,945 mm, Rain roof height: 45 mm, Base height: 100 mm |
| Number of doors | 1 |
| Lock | Closure type: 4-point locking, number of closures: 1, closure insert: BJ20027 |
| Flange plate | Size: 2, Quantity: 2 |
| Degree of protection IP according to IEC 60 529 | IP 55 |
| NEMA degree of protection | NEMA 3R, NEMA 12 |
| IK code | IK10 |
| Note | All flat parts duplicated and earthed (outer wall to inner wall); for building a single cabinet, side walls for CS Toptec, stackable, are required |
| Note on part number | To close the opening, an air conditioning unit is required |
The Rittal CS Toptec, bayed (type CS 9783888) is a double-walled outdoor enclosure for use in outdoor environments, designed for the baying of multiple enclosures. It has dimensions W x H x D 800x1800x800 mm and is specifically designed for the installation of a wall-mounted cooling unit Blue e+ Outdoor in the power range of 2 to 5 kW. The total height is 1,945 mm, determined by the 100 mm high plinth and the 45 mm high rain roof. The enclosure is designed for use in industrial environments where high mechanical and climatic resistance is required.
Applications
This enclosure is suitable for outdoor use, for example in process industry, energy plants or automation technology, where enclosures must be protected from weather influences such as rain, dust and sunlight. The double-walled construction ensures efficient thermal insulation and prevents air short-circuits between the walls. The integrated preparation for a cooling unit enables climate control of the interior, protecting sensitive electronic components from overheating.
Functions and equipment in detail
The enclosure consists of a frame made of stainless steel 1.4301 (AISI 304), providing high corrosion resistance. The flat parts, including door, rear panel, roof and base sheets, are made of aluminium AlMg3 and feature a UV-resistant, powder-coated surface in RAL 7035. The double-walled construction is fully earthed, with the outer wall doubled onto the inner wall to ensure a secure electrical connection. The front door is equipped with a 4-point locking system, ensuring secure closure. The lock is operated via a swing handle and a half cylinder with lock BJ20027.
Technology explained simply
The protection rating IP 55 according to IEC 60 529 means that the enclosure is dust-tight and protected against water jets from any angle, making it suitable for outdoor use. The protection ratings NEMA 3R and NEMA 12 complement the protection categories and confirm suitability for outdoor environments as well as for environments with contaminated air. The IK code IK10 guarantees high protection against mechanical impacts, such as blows or shocks. The system perforation in the frame with 25 mm spacing in roof, base and vertical profiles allows flexible mounting of internal components. The two mounting levels in the vertical profile offer additional mounting options.
Compatibility and accessories
The enclosure is designed for baying and requires side panels for CS Toptec, bayed for the construction of a single enclosure. A cooling unit is required to close the opening, with compatible models such as the SK 3489.340 Blue e+ wall-mounted cooling unit Outdoor 4550 W or the SK 3486.330 with 2000 W power available. Additional accessories include thermostats, hygrostats, enclosure heaters with fans, TS system chassis, as well as gland plates made of plastic or metal. The baying set CS 9781000 enables the connection of multiple enclosures.
Mounting and installation
The enclosure is fully pre-assembled and delivered with a plinth equipped with screwed gland plates and front and rear trim panels. Mounting is done via the predefined system holes in the frame. The installation of the cooling unit is carried out in the designated opening in the enclosure, with the closure being performed by the cooling unit itself.
Advantages in operation
The double-walled construction with earthed flat parts ensures high electrical safety and thermal stability. The powder-coated surface in RAL 7035 is UV-resistant and withstands long-term weather influences. The 4-point locking system provides a secure closure, protecting against unauthorised access. The integrated preparation for a cooling unit enables controlled climate control of the interior, extending the service life of electronic components. The baying capability allows flexible expansion of the enclosure system without additional effort.