| General |
| Material | Polyamide |
| For size | 2/3 |
| Suitable for part no. | 9677.200, 9677.210, 9677.215, 9677.300, 9677.310, 9677.315, 9677.340, 9677.770, 9677.780, 9677.900 |
| Rated power | 2,5 VA |
| Electrical connection type | Frame clamp |
| Insulation class | B |
| Primary current | 400 A |
| Secondary current | 5 A |
| Accuracy class | 1 |
| Test basis | IEC 60 044-1, EN 60715, DIN VDE 0414, DIN 42 600-2 |
| Connection of ring conductors | 2,5 ‐ 4 mm² |
| Rated frequency | 50 ‐ 60 Hz |
The SV 9677875 is a current transformer from manufacturer Rittal, specifically designed for integration into NH fuse switch disconnectors of sizes 2 and 3. It is used for inductive measurement of current flow in electrical installations and enables monitoring and control of loads in industrial and commercial switchgear. The current transformer is rated for a primary current of 400 A and delivers a secondary current of 5 A, making it suitable for use in measurement and protection systems standardized on secondary currents. Accuracy class 1 ensures reliable and precise current measurement, meeting the requirements of industrial electrical engineering.
Applications
This current transformer is designed for use in switchgear with NH fuse switch disconnectors, particularly in sizes 2 and 3. It is used in installations where precise current measurement is required, for example for load monitoring, energy consumption measurement, or triggering protective functions in case of overload. Compatibility with part numbers 9677.200, 9677.210, 9677.215, 9677.300, 9677.310, 9677.315, 9677.340, 9677.770, 9677.780, and 9677.900 enables direct integration into existing systems without additional effort. Mechanical integration into the assembly components is achieved with a center-to-center distance of 185 mm, ensuring the installation depth remains unchanged and enabling a space-saving design.
Functions and Equipment in Detail
The current transformer has a rated power of 2.5 VA, indicating the maximum power the secondary circuit can accept without affecting measurement accuracy. Connection is made via a frame terminal, enabling a secure and simple connection to round conductors with a cross-section of 2.5 to 4 mm². Insulation class B ensures sufficient electrical insulation and heat resistance, which is important for reliability in industrial environments. The rated frequency is between 50 and 60 Hz, matching standard grid frequencies in Europe and North America.
Technology Explained Simply
A current transformer such as the SV 9677875 transforms the high primary current (here 400 A) into a low, measurable secondary current (here 5 A), maintaining a constant ratio between primary and secondary current. This allows the current in an installation to be monitored with low energy consumption and without directly loading the measuring devices. Inductive measurement is performed without direct electrical contact to the main current circuit, increasing safety. Conformance to IEC 60 044-1, EN 60715, DIN VDE 0414, and DIN 42 600-2 ensures compliance with international and European standards for current transformers.
Compatibility and Accessories
The current transformer is specifically developed for use with NH fuse switch disconnectors of size 2 and 3. Compatibility with the listed part numbers (9677.200, 9677.210, 9677.215, 9677.300, 9677.310, 9677.315, 9677.340, 9677.770, 9677.780, 9677.900) enables direct mounting without additional modifications. Mechanical integration is achieved through the predefined mounting geometry with a 185 mm center-to-center distance, preserving the installation depth of the switch disconnector.
Mounting and Installation
Mounting is achieved by mechanical integration into the designated assembly components of the NH fuse switch disconnector. The frame terminal allows for easy and secure connection of round conductors with a cross-section of 2.5 to 4 mm². Adhering to the specified mounting distances (185 mm center-to-center distance) is essential to ensure functionality and electrical safety. No special tools or additional mounting aids are required.
Operational Advantages
The current transformer features a compact design that minimizes space requirements in switchgear without altering the installation depth. Integration into existing NH fuse switch disconnectors is achieved without additional effort, reducing installation time. The high accuracy class 1 and compliance with international standards ensure reliable and precise current measurement. The use of polyamide material provides high mechanical stability and heat resistance, increasing service life and reliability in industrial applications. The frame terminal connection enables quick and secure wiring.