Further information for Rittal 9360824 safety load disconnector 3-pole
General
Model
with electronic fuse monitoring (ESÜ)
Material
Polyamide (PA 6), flammability according to UL 94
Basic colour
RAL 35745, RAL 9005
Scope of delivery
4 fuse disconnectors, 12 reducers for fuses D 01
Electrical connection type
Spring-loaded clamp
Rated current max.
63 A
Rated operating voltage
400 V AC
Note
functionality of electronic fuse monitoring only available when load is connected
Cable exit
Below
Number of poles
3-pole
Suitable for busbar system
RiLineX, RiLine60
Width
35,8 mm
Height
263 mm
Depth
104,2 mm
Suitable for busbars
15 x 5/10 mm, 20 x 5/10 mm, 30 x 5/10 mm
Over voltage category
4
Pollution degree
3
Standards
IEC/DIN EN 60 947-3
Rated insulation voltage Ui
440 V
Maximum power dissipation
5,5 W
Degree of protection IP according to IEC 60 529
IP 2XB
Operating air humidity max.
90 %
Operating temperature range
-5 °C...55 °C
Storage temperature range
-25 °C...75 °C
Humidity (non-condensing)
10...90 %
Utility category
AC-22B (400 V/100 A)
Fuse links
D 01 (with reducer), D 02, 10 x 38 mm
Fire load
6,433 MJ/m²
Copper content (kg/piece)
0,105
PCF/VE (Cradle-to-Gate)
14,81
With electronic fuse monitoring (ESÜ)
The Rittal RX 9360824 is a 3-pole fuse switch disconnector, designed for use in industrial electrical installations. It features electronic fuse monitoring (ESÜ) and is designed for a rated current of up to 63 A and a rated operational voltage of 400 V AC. The device is specifically developed for mounting on RiLineX and RiLine60 busbar systems, allowing tool-free snap-on installation onto rails with a thickness of 5 mm or 10 mm. The semi-automatic adjustment to rail thickness simplifies installation and ensures secure fastening without additional tools.
Applications
This fuse switch disconnector is suitable for use in industrial enclosures and distributions where safe and monitorable disconnection of power supply is required. It is commonly used in installations with high safety requirements, where monitoring the fuse status is important. The integrated optical LED fuse monitoring enables visual inspection of the fuse status, while the electronic fuse monitoring with alarm contacts provides automatic signaling of faults or failures. However, the functionality of the electronic monitoring requires a connected load.
Functions and Equipment in Detail
The device is equipped with spring-cage terminals, enabling maintenance-free conductor connection up to 16 mm². The wiring exit is at the bottom, supporting flexible cabling in enclosures. Fuse inserts can be used in sizes D 01 (with reducer), D 02, and 10 x 38 mm. The included reducers for D 01 fuses allow the use of these fuse types in the device. The fuse inserts are connected without screw caps, ensuring a secure and reliable contact. The switch can be locked in both ON and OFF positions, providing additional safety during maintenance work.
Technology Explained Simply
The electronic fuse monitoring (ESÜ) monitors the status of the installed fuse and signals via alarm contacts if a fuse has blown or is not correctly inserted. The optical LED indicator complements this with visual control. The spring-cage terminals ensure a secure and durable connection of conductors without requiring screw caps. The material polyamide (PA 6) offers high mechanical stability and is flame-retardant according to UL 94. The protection rating IP 2XB protects against finger contact and vertical dripping water, which is sufficient for use in enclosed enclosures.
Compatibility and Accessories
The fuse switch disconnector is suitable for busbars with widths of 15 mm, 20 mm, or 30 mm and thicknesses of 5 mm or 10 mm. It can be mounted on RiLineX and RiLine60 busbar systems. As accessories, grip protection profiles (e.g. RX 9365025) and mounting clips (e.g. RX 9365027) are available, providing additional safety during installation and operation.
Mounting and Installation
Mounting is tool-free via snap-on onto the busbar. The semi-automatic adjustment to rail thickness (5 mm or 10 mm) is achieved by a simple setting on the device. The spring-cage terminals allow quick and secure connection of conductors. Installation takes place in a closed enclosure, with an operating temperature range between -5 °C and 55 °C. The operating humidity should not exceed 90%.
Advantages in Operation
The switch offers high operational safety through integrated fuse monitoring, which functions both optically and electronically. The tool-free mounting and maintenance-free spring-cage connection reduce installation time and maintenance effort. The use of polyamide (PA 6) with flame-retardant properties according to UL 94 increases operational safety. The protection rating IP 2XB ensures sufficient protection against contact and dripping water in enclosed enclosures. The rated insulation voltage of 440 V and overvoltage category 4 make the device suitable for industrial applications. The service category AC-22B (400 V/100 A) defines the operating conditions for the switch disconnector.
Scope of Delivery
The scope of delivery includes 4 fuse switch disconnectors and 12 reducers for D 01 fuses. These components are required for installation and operation of the device.