| General |
| Material | Polyamide, flammability rating according to UL 94-V0 |
| Colour | RAL 7035 |
| Scope of delivery | Connection straps, groove stones |
| Rated current max. | 250 A |
| Rated operating voltage | 690 V, 4~ |
| Note | Cable exit: switch output or as outgoing cable from switching device, the specified technical data may vary for UL applications |
| Electrical values UL (SCCR) | 65 kA - 480 V, Circuit Breaker max. 250 A, DIVQ/7 |
| Cable exit | Above |
| For rail systems with centre spacing | 60 mm |
| Number of poles | 4-pole |
| Width | 140 mm |
| Height | 310 mm |
| Suitable for busbars | Height: 5, 10 mm |
| Suitable for manufacturer (type) | ABB (T3S, XT3), Eaton (NZM2-4/250 A), Schneider Electric (NS(X)100, NS(X)160, NS(X)250), Schrack (MC2), Siemens (VL160X, VL160, VL250, 3RV10 63, 3VA12/20/21/22, 3VA61/62) |
| Copper content (kg/piece) | 1,134 |
The Rittal SV 9345604 is a
CB-device adapter for use in industrial power distribution systems. It serves as a connection component between power circuit breakers and busbars, ensuring a safe and reliable electrical connection. The device is 4-pole and designed for a
rated current of up to 250 A and a
rated operating voltage of 690 V, 4~. The cable exit is at the top, enabling flexible integration into enclosures. The product is made of
polyamide, classified as flame retardant according to UL 94-V0, and is available in the colour
RAL 7035.
Applications
The CB-device adapter is intended for use in industrial and commercial electrical installations, particularly in enclosures where power circuit breakers are connected to busbars. It is suitable for applications requiring high electrical load capacity and mechanical stability. Standard use is specified for switchgear systems with an operating voltage up to 690 V and a current up to 250 A. The construction is designed for use in busbar systems with a centre-to-centre spacing of 60 mm, enabling universal mounting in common enclosure systems.
Functions and Equipment in Detail
The adapter is equipped with
connection straps and
slot inserts to ensure secure fastening to the busbars. The connection straps enable a firm connection between the circuit breaker and the busbar, ensuring reliable current transmission. The slot inserts ensure precise positioning and mechanical stability. The number of poles is 4, required for use in three-phase AC systems with an additional protective earth conductor (PE). Dimensions are 140 mm (width) and 310 mm (height), enabling compact mounting in standard enclosures.
Technology Explained Simply
The device is designed for use with various manufacturers of power circuit breakers, including ABB (T3S, XT3), Eaton (NZM2-4/250 A), Schneider Electric (NS(X)100, NS(X)160, NS(X)250), Schrack (MC2), and Siemens (VL160X, VL160, VL250, 3RV10 63, 3VA12/20/21/22, 3VA61/62). Compatibility with these models is ensured by the specific design of the adapter. The fit is for busbars with a height of 5 mm or 10 mm. Electrical safety is ensured by the
SCCR values (Short-Circuit Current Rating) of 65 kA at 480 V for UL applications, with a maximum circuit breaker current of 250 A. The designation DIVQ/7 refers to the switching class according to UL standard. The choice of polyamide material with UL 94-V0 flammability rating ensures high safety at elevated temperatures and in case of fire.
Compatibility and Accessories
The adapter is specifically developed for use with power circuit breakers from the mentioned manufacturers. The fit to busbars with 5 mm or 10 mm height enables flexible integration into existing installations. As an accessory, a
slot insert M4/M5 for CB-device adapter is offered, supporting mounting on various busbar systems. The use of this accessory is optional and serves to adapt to specific mounting requirements.
Mounting and Installation
Mounting is performed by securing the connection straps to the busbars and then connecting to the power circuit breaker. The slot inserts ensure secure positioning. Installation does not require special tools, but compliance with electrical safety regulations and correct fastening of the connection straps is required. Cable exits are at the top, enabling clear and organised wiring. Mounting is possible in standard enclosures with 60 mm centre-to-centre spacing.
Operational Advantages
The CB-device adapter provides a reliable and safe electrical connection between the circuit breaker and the busbar. The use of polyamide with UL 94-V0 flammability rating increases operational safety. Compatibility with various circuit breaker manufacturers and busbar heights enables flexible use in different installations. Pre-fabricated connection straps and slot inserts reduce mounting time and increase mounting accuracy. The electrical ratings, particularly the SCCR of 65 kA, ensure high safety in the event of short-circuit incidents.
Copper Content and Environmental Aspects
The copper content is 1.134 kg per unit, indicating the use of copper in the connection straps and other conductive parts. This value is relevant for recycling and disposal aspects, as well as for assessing the material composition in the context of circular economy.