| General |
| Material | Stainless steel 1.4301 (AISI 304), 1.5 mm |
| Scope of delivery | Including main door lock, cover plate and mounting material. |
| Width | 103 mm |
| Height | 2.000 mm |
| Depth | 600 mm |
| Note | Mounting of hood only on single-door cabinet with door frame |
| Type rating according to UL 50E | Type 1, Type 12 |
| Degree of protection IP according to EN 60 529 | IP 55 in conjunction with VX series cabinets |
| NEMA degree of protection | NEMA 12 (in combination with VX series cabinets) |
The Rittal VX 8952010 disconnect switch hood is a stainless steel module for integration into single-door enclosures of the VX series. It is designed to convert a standard enclosure into a disconnect switch enclosure that meets the requirements of UL 508 A. The hood is made of stainless steel 1.4301 (AISI 304) with a wall thickness of 1.5 mm, ensuring high corrosion resistance and mechanical strength. Dimensions are 103 mm width, 2,000 mm height, and 600 mm depth. Installation is exclusively on single-door enclosures with door tube frame, and the hood can be mounted either on the left or right side of the enclosure.
Applications
The disconnect switch hood is designed for use in industrial electrical installations, particularly in bayed combinations. It enables safe disconnection of electrical systems in accordance with UL regulations. The hood is designed for use with operating levers of main switches from various manufacturers, including Allen Bradley, Square D, General Electric, Eaton, and Siemens. Compatibility includes specific models such as Siemens operating mechanisms with Bowden cable (e.g. 3VA9137-0CK12, 3VA9277-0CK12, 3VA9477-0CK12) as well as depth-variable mechanisms (e.g. 3VA9138-0DK72). The hood is suitable for integration into enclosures with NEMA 12 and Type 1 protection ratings, achieving an overall protection rating of IP 55 when used with VX enclosures.
Functions and Equipment in Detail
The hood is equipped with a main door interlock that enables safety interlocking of enclosures and enclosure combinations in accordance with UL regulations. The integrated interlock ensures that the enclosure door can only be opened when the disconnect switch is in the off position. The front of the hood features two cutouts for operating levers, which can be mounted at different heights to allow flexible installation with various switch types. The delivery includes the main door interlock, a cover plate, and the required mounting hardware.
Technology Explained Simply
The disconnect switch hood meets the requirements of UL 508 A, a standard for industrial control and power enclosures that defines safety requirements for electrical disconnection and access to electrical components. The integrated interlock works in conjunction with the operating mechanism of the main switch, ensuring a secure mechanical interlock between switch position and enclosure access. The protection rating IP 55 (dust- and splash-proof) in combination with VX enclosures makes the hood suitable for use in industrial environments with increased contamination and moisture exposure. The NEMA 12 protection rating corresponds to protection against dust, splashing water, and light spraying, which is typical for indoor installations.
Compatibility and Accessories
The hood is specifically designed for use with enclosures of the VX series. In combination with a mounting plate spacer, the mounting area of the main enclosure can be increased by up to 14%, facilitating the installation of additional components. Compatible accessories include door interlocks for bayed combinations, auxiliary door interlocks, and mounting plate spacers for VX and TS enclosures. The hood is not intended for enclosures without a door tube frame.
Installation and Mounting
Installation is performed on a single-door enclosure with a door tube frame. The hood can be mounted on the left or right side of the enclosure, increasing flexibility in planning bayed combinations. The full mounting area of the enclosure remains intact, as the hood does not interfere with the enclosure’s mounting surface. Mounting is done using the included hardware.
Operational Advantages
The disconnect switch hood enables safe and standard-compliant disconnection of electrical systems, making maintenance and servicing safer. The use of stainless steel ensures long service life even in corrosive environments. The integrated interlock reduces the risk of misoperation and increases operator safety. Compatibility with various switch manufacturers and the ability to mount at different positions increase flexibility in planning and installing enclosures. The expansion of the mounting area via the mounting plate spacer provides additional space for components without changing the enclosure dimensions.