| General |
| Model | PDU, metered plus |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | Measurement per phase or input, additional measurement per output socket, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.495 mm |
| Number of sockets and type | 24 x C13 / 6 x C19 |
| Socket outlets | 24 x C 13, 6 x C 19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 11 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
The Rittal DK 7979536 is a
PDU (Power Distribution Unit) of the
metered plus type, specifically designed for use in IT network and server racks. It serves as an intelligent power distribution unit with integrated energy measurement, capturing the power demand of individual loads at the output sockets. The device is housed in a compact aluminium profile with a black anodized surface and has an overall length of 1,495 mm, a width of 44 mm, and a depth of 70 mm. Power supply is via a CEE connection cable with a length of 3 m, and the PDU is self-powered, requiring no external power source. The rated operating voltage is 400 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 11 kW. Power input is via a three-phase connection (3~). The PDU is designed for use in Rittal VX IT cabinet frames or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm.
Applications
The DK 7979536 is intended for use in professional IT infrastructures such as data centres, server rooms, and network-server racks. It enables precise energy management and monitoring, particularly in environments where detailed load distribution and analysis are required. Vertical mounting in Zero-U-Space is tool-free, simplifying installation in existing racks. The phase colour coding (L1=pink, L2=black, L3=white) supports identification and maintenance.
Functions and Equipment in Detail
The PDU features 24 C13 sockets and 6 C19 sockets, made of plastic. Energy measurement is performed per phase or input as well as per individual output socket. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures continuous timekeeping even during power failure. An integrated electromagnetic buzzer enables acoustic alarm signalling. Voltage, current, and power thresholds can be set individually per output socket, allowing custom warning and alarm limits. The device includes a bright TFT display with 128x128 pixels (RGB) and backlighting, showing power data and basic configuration. The display unit is rotatable by 180° and replaceable. Multicolour LEDs (green/yellow/red) indicate the switching state and thresholds per output socket.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) ensuring data processing and transmission. Power supply is redundant across all phases, ensuring fault-tolerant operation. The integrated, fully redundant power supply ensures high availability. The PDU measures voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, neutral conductor current, and unbalanced load. Fuse monitoring is available for PDUs with integrated fuses. Operating temperature ranges from 5 °C to 50 °C, with non-condensing humidity between 10 % and 95 %. Storage temperature is from -20 °C to 70 °C.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces, including a fully redundant Ethernet interface (10/100/1000 Mbit/s), a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for up to 16 environmental sensors of type CMC III, and a serial interface RS232 (RJ12) for LTE unit, scripting, and CLI. Protocol support includes web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, and FTP/SFTP for updates and file transfers. User management includes rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server integration (up to 2 servers). Email alerts on alarm are possible via SMTP. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation and status monitoring can be integrated. Differential current measurement (Type B) is available per input, phase, or fuse. Monitoring of the optional surge protection is also possible. Connection of CMC III CAN-Bus sensors for environmental monitoring is possible, with up to 16 sensors connectable. Other enclosure colours are available optionally.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes mounting hardware. The PDU is designed for use in VX IT enclosures with cabinet frames ≥ 1,800 mm or 48,3 cm ( 19 inch ) profile rails ≥ 1,800 mm. The connection cable has a length of 3 m and is fitted with a CEE connector.
Operational Advantages
The DK 7979536 offers high measurement accuracy, redundant power supply, and comprehensive network integration. Detailed energy measurement per output socket enables precise load distribution and analysis. The integrated real-time clock and acoustic buzzer support alarm signalling. Adjustable thresholds and user management with rights management enhance security and control. The energy-saving design with low self-consumption reduces the device’s own energy usage. Support for numerous protocols and interfaces simplifies integration into existing IT infrastructures and DCIM systems. The ability to connect CMC III sensors extends monitoring capabilities to environmental parameters such as temperature or humidity.