| General |
| Model | PDU, metered plus |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | Measurement per phase or input, additional measurement per output socket, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 845 mm |
| Number of sockets and type | 12 x C13 / 1 x C19 |
| Socket outlets | 12 x C 13, 1 x C 19 |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,200 mm |
The Rittal DK 7979510 is a
PDU (Power Distribution Unit) of the
metered plus type, specifically designed for use in IT network and server racks. It serves for power distribution and energy measurement within 48,3 cm ( 19 inch ) enclosures, particularly in Rittal VX IT systems. The unit features a compact design with a width of 44 mm, depth of 70 mm, and length of 845 mm, allowing it to be installed tool-free in Zero-U-Space areas. Power supply is via a CEE connection cable with a length of 3 m, and the PDU is self-powered, requiring no external power source. The rated operating voltage is 230 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 3.7 kW.
Applications
The PDU is designed for use in IT infrastructures, particularly in server and network racks where precise energy measurement and control are required. It is suitable for racks with a minimum height of 1,200 mm (VX IT enclosure frame or 48,3 cm ( 19 inch ) profile rails). The integrated energy measurement per output socket enables detailed monitoring of energy consumption of individual devices, which is important for efficiency optimization and load distribution in data centers. The color coding of phases (L1=pink, L2=black, L3=white) supports assignment and safety during installation.
Functions and Equipment in Detail
The PDU features 12 sockets of type C13 and one socket of type C19, made of plastic. The measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. Measurement is performed per phase or input as well as per individual output socket. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures accurate time-stamping of measurement values.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) responsible for data processing and communication. Power supply is redundant across all phases, ensuring fault-tolerant operation. The display is integrated into the enclosure, rotatable by 180°, and replaceable. It is a bright TFT display with 128x128 pixels (RGB) and backlighting, showing performance data and basic configuration. Multicolored LEDs (green/yellow/red) indicate the switching state and threshold values per output socket. An integrated electromagnetic buzzer enables acoustic alarm signaling in case of exceedances. Threshold values for voltage, current, and power can be individually set per output socket.
Compatibility and Accessories
The PDU is equipped with a fully redundant Ethernet interface (10/100/1000 Mbit/s), suitable for integration into networks and DCIM systems. Configurations, firmware updates, data logging, and scripting can be performed via interfaces USB 2.0 (USB-A), CAN-Bus (RJ45), and RS232 (RJ12). The CAN-Bus interface allows connection of up to 16 CMC III environmental sensors for monitoring temperature, humidity, or other parameters. Optionally, a Type 3 surge protection with replaceable discharge elements during operation can be integrated, with its status monitored. Differential current measurement (Type B) per input/phase/fuse is also possible. The PDU supports protocols such as HTTP/HTTPS, SSH, Telnet, SNMP, Modbus/TCP, OPC-UA, FTP/SFTP, NTP, TCP/IP v4 & v6, DHCP, DNS, and MIB integration into third-party DCIM software. User management includes rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server integration (up to 2 servers). E-mail alarms (SMTP) can be sent when threshold values are triggered.
Installation and Mounting
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes mounting hardware. The PDU is designed for vertical mounting and can be installed in enclosures with a minimum height of 1,200 mm. The connection cable (CEE, 3 m) allows flexible positioning of the power input. The integrated power supply and redundant supply across all phases ensure high availability.
Operational Advantages
The PDU offers high measurement accuracy, detailed energy measurement per output socket, and comprehensive network communication. The integrated real-time clock, acoustic alarm signaling, and adjustable threshold values support proactive monitoring and error prevention. The energy-saving design with low self-consumption reduces the PDU's own energy demand. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA facilitates integration into existing monitoring and management systems. The ability to connect environmental sensors via CAN-Bus extends functionality for comprehensive rack environment monitoring. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). Storage is possible in the range of -20 °C to 70 °C. Compliance with standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21, as well as directives EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, ensures safety and compatibility.
Batteries are not included in the delivery scope.