| General |
| Model | PDU, managed |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | CMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.895 mm |
| Number of sockets and type | 18 x C13 / 12x Combi (C13/C19) |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Cabinet type: VX IT cabinet frame: ≥ 2,000 mm, cabinet type: VX IT 19"-profile rails: ≥ 2,200 mm |
The Rittal DK 7979445 is a
managed PDU (Power Distribution Unit) for use in IT network and server racks. It serves for power distribution and monitoring in high-performance IT environments and provides energy measurement and switching functions for each individual outlet socket. The device is housed in a compact aluminium profile with a black anodized surface and features an integrated control and display unit with TFT display. The PDU is designed for use in Rittal VX IT and TS IT racks, enabling tool-free mounting in Zero-U-Space.
Applications
The PDU is designed for use in professional IT infrastructures, particularly in server and network racks, where precise energy management, load monitoring, and remote control are required. It is suitable for environments requiring high availability and transparency in power distribution, such as data centres, data hubs, or critical IT systems. The integrated energy monitoring enables detailed analysis of power consumption per outlet, which is helpful for energy efficiency measures and load management.
Functions and Equipment in Detail
The PDU features 18 C13 sockets and 12 Combi sockets (C13/C19), suitable for powering servers, network devices, and other IT end devices. The sockets are made of plastic and ensure safe and reliable power supply. The rated operating voltage is 400 V (AC), with a maximum rated current of 32 A, corresponding to a rated power of 22 kW. Power supply is via a CEE plug with a 3 m long supply cable. The PDU is self-powered and does not require external power supply.
Technology Explained Simply
The PDU is equipped with a powerful ARM Cortex A8 processor, enabling energy monitoring, switching functions, and network communication. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures time accuracy of measurements and logs, even during power failure. Switching functions include programmable power-on behaviour after voltage recovery (on, off, last status) and programmable switching based on time or logic rules. The relays are bistable, enabling low power consumption and high switching capacity even at high inrush currents (up to max. 300 A). Relay states are retained even during power failure.
Compatibility and Accessories
The PDU is suitable for Rittal VX IT enclosures with a cabinet frame ≥ 2,000 mm or 48,3 cm ( 19 inch ) profile rails ≥ 2,200 mm. It can be connected to CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Compatible accessories include CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 sockets, mounting adapters, a universal lock for C14/C20 plugs, a numeric code lock, and a transponder reader for CMC III systems.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The device is mounted using included fastening materials. The phase colour coding (L1=pink, L2=black, L3=white) facilitates assignment and securing of circuits. The display unit is rotatable by 180° and replaceable, allowing flexible adaptation to mounting position.
Operational Advantages
The PDU offers high operational reliability through redundant power supply across all phases and integrated fault detection. Network interfaces enable remote monitoring and control via various protocols (HTTP/HTTPS, SSH, Telnet, SNMP, Modbus/TCP, OPC-UA). User management with rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server integration (up to 2 servers) enables secure and structured usage. E-mail alarms (SMTP) and an integrated electromagnetic buzzer provide acoustic and e-mail notifications for faults. The fully redundant Ethernet interface (10/100/1000 Mbit/s) ensures stable network connection. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). Storage is possible in the range of -20 °C to 70 °C. The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.
Batteries are not included in the delivery scope.