Rittal 7979437, EAN: 4028177948211

Rittal 7979437 PDU Managed 32A/3P CEE 24xC13 6xC19

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979437 PDU Managed 32A/3P CEE 24xC13 6xC19

Lieske Part No. 1101074
Mfg Part No 7979437
EAN-Code 4028177948211
Manufacturer Rittal
Here only 2.080,93 EUR
2.476,31 EUR incl. VAT

Further information for Rittal 7979437 PDU Managed 32A/3P CEE 24xC13 6xC19

General
ModelPDU, managed
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Width44 mm
Depth70 mm
Length1.740 mm
Number of sockets and type24 x C13 / 6 x C19
Socket outlets24 x C 13, 6 x C 19
Rated operating voltage400 V (AC)
Rated current (max.)32 A
Nominal power22 kW
Power suppliesNumber: 1, phases per input: 3~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
Number of RJ45 ports for sensor units max6
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forCabinet type: VX IT cabinet frame: ≥ 2,000 mm, Cabinet type: VX IT 19"-profile rails: ≥ 2,000 mm
The Rittal DK 7979437 is a managed PDU (Power Distribution Unit) for use in IT network and server racks. It is designed for vertical power distribution in 19-inch enclosures and provides comprehensive energy measurement and monitoring functions for each individual outlet socket. The device is designed for use in high-performance IT environments where precise control, monitoring, and documentation of power consumption values are required. The PDU is mounted toollessly in the Zero-U-Space of Rittal VX IT or TS IT racks and is therefore ideally suited for racks with a minimum length of 2,000 mm.

Applications

The PDU is designed for use in data centers, server rooms, and IT infrastructures where central control and monitoring of power supply for multiple devices is necessary. The integrated functions enable precise energy management, load distribution, and fault diagnosis. The color coding of phases (L1=pink, L2=black, L3=white) supports safe and unambiguous assignment of circuits. The PDU is designed for a rated operating voltage of 400 V (AC) and can deliver a nominal current of up to 32 A at a nominal power of 22 kW.

Functions and Equipment in Detail

The PDU features 24 sockets of type C13 and 6 sockets of type C19, suitable for supplying IT and network devices. The sockets are made of plastic and integrated into an aluminum profile, black anodized. Power supply is via a CEE plug (16 A/32 A) with a supply cable of 3 m length. The PDU is self-powered, i.e., it does not require external power for its control and monitoring functions. The integrated real-time clock with battery backup (max. 10 years, replaceable) ensures time accuracy of measurement data even during power failure. Measurement accuracy is ±1 % (kWh) according to EN 62 053-21.

Technology Explained Simply

The PDU is equipped with a powerful ARM Cortex A8 processor, enabling processing of measurement data and control of functions. The device's power supply is redundant across all phases, ensuring fault-tolerant operation. The integrated, fully redundant power supply ensures that the PDU remains operational even if one phase fails. The sockets are equipped with multicolored LEDs (green/yellow/red) indicating switch status and threshold values. A bright TFT display (128x128 pixels, RGB, with backlight) shows performance data and basic configuration. The display is rotatable by 180° and replaceable to ensure optimal readability during vertical mounting.

Compatibility and Accessories

The PDU is designed for mounting in Rittal VX IT enclosure frames and 48,3 cm ( 19 inch ) profile rails with a minimum length of 2,000 mm. It is expandable with a variety of options, including a Type 3 surge protection device with replaceable discharge elements during operation, which can be integrated into the PDU enclosure. Differential current measurement (Type B) is available per input, phase, or fuse. Monitoring of the optional surge protection is also integrated. The PDU supports connection of up to 16 CMC III CAN-Bus sensors for environmental monitoring, with sensors connected via an RJ45 interface. Compatible accessories include CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 sockets, mounting adapters, a universal locking device for C14/C20 plugs, and a numeric code lock for CMC III.

Mounting and Installation

Mounting is toolless in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the necessary mounting materials. Vertical mounting enables optimal rack utilization and clear assignment of circuits. The PDU is designed for an operating temperature of 5 °C to 50 °C and a humidity of 10 % to 95 % (non-condensing). Storage temperature is -20 °C to 70 °C.

Operational Advantages

The PDU offers high operational reliability through redundant power supply and integrated fault detection. Programmable switching functions enable sequential switching of outputs after power restoration to avoid overload peaks. Relay states are stored even during power failure, ensuring stable configuration recovery. The integrated real-time clock and measurement accuracy according to EN 62 053-21 ensure reliable data. Support for protocols such as SNMP, Modbus/TCP, OPC-UA, and MIB enables integration into existing DCIM systems. The email alarm function (SMTP) and connection to Syslog servers (max. 2 servers) support proactive fault resolution. User management with rights management and integration with LDAP(S), Radius, or Active Directory enables secure and centralized management of access rights. The fully redundant Ethernet interface (10/100/1000 Mbit/s) ensures stable network connection. The USB interface (USB-A) is used for mass configuration, firmware updates, and data logging. The serial interface RS232 (RJ12) supports connection of an LTE unit, scripting, and CLI. Use of own certificates and TLS 1.2 ensures secure communication. An integrated electromagnetic buzzer provides acoustic alarm signaling. The PDU is certified for use in IT infrastructures according to the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.