| General |
| Model | PDU, managed |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | CMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.495 mm |
| Number of sockets and type | 12 x C13 / 12x Combi (C13/C19) |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 7,4 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Rittal DK 7979421 is a
managed PDU (Power Distribution Unit) designed for use in IT network and server racks. It provides power distribution and comprehensive energy measurement and monitoring functions for each individual output socket. The unit is designed for use in 19-inch systems and can be tool-free mounted vertically in the Zero-U-Space of Rittal VX IT or TS IT racks. Power supply is via a CEE plug (16 A/32 A) with a 3 m long supply cable. The PDU is rated for an operating voltage of 230 V (AC) and supports a nominal current of up to 32 A and a nominal power of 7.4 kW.
Applications
The PDU is designed for use in professional IT infrastructures, particularly in data centres, server rooms and network server racks. It is suitable for powering IT systems requiring precise energy monitoring and control. Vertical mounting in the Zero-U-Space enables efficient use of rack space, especially in racks with a minimum length of 1,800 mm. The unit is designed for operation in environments with temperatures from 5 °C to 50 °C and humidity from 10 % to 95 % (non-condensing).
Functions and Equipment in Detail
The DK 7979421 features 12 C13 sockets and 12 Combi sockets (C13/C19), each of which can be individually monitored and controlled. Energy measurement is performed with an accuracy of ±1 % (kWh) according to standard EN 62053-21. Each output socket can be individually configured, with adjustable limits for voltage, current and power. Warnings or alarms are triggered if these limits are exceeded. The PDU offers programmable switching behaviour, including sequential switching on after voltage recovery, to avoid overload peaks. Relay states are retained even during power failure, enabling continuous operation.
Technology Explained Simply
The PDU is equipped with an integrated, fully redundant power supply unit that can be powered from all phases, ensuring fault-tolerant power supply. Control is handled by a powerful CPU (ARM Cortex A8), which processes measurement data and controls the outputs. A bright TFT display (128x128 pixels, RGB) with backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable, allowing flexible adaptation to the mounting position. Multicoloured LEDs (green/yellow/red) indicate the switching state and limits for each output socket. An integrated electromagnetic buzzer enables acoustic alarm signalling.
Compatibility and Accessories
The PDU is equipped with a CAN-Bus interface (RJ45), allowing up to 16 CMC III environmental sensors to be connected. These sensors enable monitoring of environmental parameters such as temperature and humidity. Various accessories are also available, including CAN-Bus cables in different lengths (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 sockets, mounting adapters, a universal locking mechanism for C14/C20 plugs, a numeric code lock and a transponder reader for CMC III systems.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The PDU is supplied with a tool-free mounting kit, simplifying installation. The phase colour coding (L1=pink, L2=black, L3=white) supports correct assignment of power circuits. The unit is designed for enclosure types with a minimum length of 1,800 mm, suitable for both VX IT enclosure frames and 19-inch profile rails.
Operational Advantages
The DK 7979421 offers high operational reliability through redundant power supply and integrated fault detection. Energy measurement per output socket enables precise load distribution and monitoring. The network interface (fully redundant Ethernet interface 10/100/1000 Mbit/s) allows integration into DCIM systems and remote control via protocols such as SNMP, Modbus/TCP, OPC-UA and MIB. Support for TLS 1.2, LDAP(S), Radius and Active Directory enables secure and central user management. The PDU is also designed for operation with PoE (Power over Ethernet), enabling emergency power supply for web servers. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures time accuracy even during power failure.
Scope of Delivery
Includes mounting hardware.