Rittal 7979417, EAN: 4028177973497

Rittal 7979417 PDU managed 16A/1P C20 12xC13 + 1xC19

Rittal 7979417 PDU managed 16A/1P C20 12xC13 + 1xC19

Lieske Part No. 900352
Mfg Part No 7979417
EAN-Code 4028177973497
Manufacturer Rittal
Here only 1.265,00 EUR
1.505,35 EUR incl. VAT

Further information for Rittal 7979417 PDU managed 16A/1P C20 12xC13 + 1xC19

General
ModelPDU, managed
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsCMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors, other housing colours available
Width44 mm
Depth70 mm
Length845 mm
Number of sockets and type12 x C13 / 1 x C19
Socket outlets12, 1
Rated operating voltage230 V (AC)
Rated current (max.)16 A
Nominal power3,7 kW
Power suppliesNumber: 1, Phases per input: 1~
Electrical connection typeIEC C20
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,200 mm
The Rittal DK 7979417 is a managed PDU (Power Distribution Unit) for use in IT network and server racks. It is designed for power distribution and provides comprehensive energy measurement and monitoring functions for each individual output socket. The device is housed in a compact aluminium profile housing with a black anodized surface and has an overall length of 845 mm, a width of 44 mm, and a depth of 70 mm. Power supply is via an IEC C20 connector, and the PDU is self-powered, requiring no external power source. The rated operating voltage is 230 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 3.7 kW.

Applications
The PDU is designed for use in IT infrastructures, particularly in Rittal VX IT racks with a cabinet frame or 48,3 cm ( 19 inch ) profile rails with a length of at least 1,200 mm. When mounted vertically, it can be installed tool-free in Zero-U-Space. The phase colour coding (L1=pink, L2=black, L3=white) supports assignment and safety during installation. The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and a humidity range of 10 % to 95 % (non-condensing).

Functions and Equipment in Detail
The PDU features 12 C13 and one C19 socket outlets, each of which can be individually monitored and controlled. Energy measurement is performed with an accuracy of ±1 % (kWh) according to EN 62053-21. Individual thresholds for voltage, current, and power can be set for each output socket, triggering warnings or alarms if these thresholds are exceeded. An integrated electromagnetic buzzer enables acoustic alarm notification. Switching functions include programmable power-on behaviour after voltage recovery (on, off, last state) and programmable switching based on time or logical conditions. Relay states are retained even during power failure, ensuring secure recovery.

Technology Explained Simply
The PDU is equipped with a powerful ARM Cortex A8 processor, enabling processing of measurement and control data. A bright TFT display with 128x128 pixels (RGB) and backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring optimal visibility in various mounting positions. The PDU is redundantly powered from all phases, ensuring fault-tolerant operation. It features an integrated, fully redundant power supply that can be powered from all phases. The real-time clock is equipped with a battery backup that lasts up to 10 years and is replaceable.

Compatibility and Accessories
The PDU is designed for connection to CMC III CAN-Bus sensors for environmental monitoring, supporting up to 16 sensors. Interfaces include a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for sensors, a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI, and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Protocols supported include Web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, and FTP/SFTP for updates and file transfers. The PDU supports connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers), and enables email alerts on alarm (SMTP). Integrated user management with role-based access control is included.

Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT racks. The delivery includes mounting hardware. The PDU is designed for use in IT infrastructures, with mounting possible in a cabinet frame or on 48,3 cm ( 19 inch ) profile rails with a length of at least 1,200 mm. The phase colour coding facilitates installation and maintenance.

Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated real-time clock. Individual monitoring and control of output sockets enables precise energy management and load distribution. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA facilitates integration into existing DCIM systems. The ability to define thresholds individually per socket increases flexibility and safety. The integrated real-time clock with battery backup ensures continuous timekeeping even during power failure. The PDU is designed for indoor use and complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.

Note: Batteries are not included in the delivery scope.