Rittal 7979415, EAN: 4028177948129

Rittal 7979415 PDU Managed 16A/1P CEE 24xC13 4xC19

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979415 PDU Managed 16A/1P CEE 24xC13 4xC19

Lieske Part No. 1910665
Mfg Part No 7979415
EAN-Code 4028177948129
Manufacturer Rittal
Here only 1.716,49 EUR
2.042,62 EUR incl. VAT

Further information for Rittal 7979415 PDU Managed 16A/1P CEE 24xC13 4xC19

General
ModelPDU, managed
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Width44 mm
Depth70 mm
Length1.295 mm
Number of sockets and type24 x C13 / 4 x C19
Socket outlets24 x C 13, 4 x C 19
Rated operating voltage230 V (AC)
Rated current (max.)16 A
Nominal power3,7 kW
Power suppliesNumber: 1, Phases per input: 1~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forhousing type: VX IT cabinet frame: ≥ 1.800 mm, housing type: 19"-profile rails: ≥ 1.800 mm
The Rittal DK 7979415 is a managed PDU (Power Distribution Unit) for use in IT network and server racks. It is designed for power distribution and monitoring in 48,3 cm ( 19 inch ) enclosures and offers extensive energy measurement and control functions for each individual output socket. The device is housed in a compact aluminium profile with a black anodized surface and has an overall length of 1,295 mm, a width of 44 mm, and a depth of 70 mm. The PDU is rated for a nominal operating voltage of 230 V (AC) and supports a nominal current of up to 16 A, corresponding to a nominal power of 3.7 kW.

Applications

The PDU is specifically designed for use in IT infrastructures, particularly in racks of type Rittal VX IT or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. When mounted vertically, it can be installed tool-free in Zero-U-Space, minimizing rack space requirements. The phase colour coding (L1=pink, L2=black, L3=white) supports identification and maintenance. The PDU is intended for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity levels from 10 to 95 % (non-condensing).

Functions and Equipment in Detail

The PDU features 24 C13 sockets and 4 C19 sockets, each of which can be individually monitored and controlled. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. Each output socket can be individually configured, including adjustable thresholds for voltage, current, and power, triggering warnings and alarms based on settings. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures time accuracy even during power failure. An integrated electromagnetic buzzer enables acoustic alarm signaling.

Technology Explained Simply

The PDU is self-powered and requires no external power supply. Power is supplied redundantly from all phases, ensuring fault-tolerant operation. Control is managed by a powerful CPU (ARM Cortex A8) and a bright TFT display with 128x128 pixels (RGB), which is rotatable and replaceable. The display shows performance data and basic configurations. Multicoloured LEDs (green/yellow/red) indicate the switching status and thresholds for each output socket. The PDU includes an integrated, fully redundant power supply, which can be powered from all phases.

Compatibility and Accessories

The PDU is equipped with a variety of interfaces, including a fully redundant Ethernet interface (10/100/1000 Mbit/s), a USB 2.0 interface (USB-A) for mass configuration, firmware updates, and data logging, and a CAN-Bus interface (RJ45) for connecting up to 16 environment sensors of type CMC III. A serial interface RS232 (RJ12) allows connection to LTE modules, scripting, and CLI. The PDU supports protocols such as HTTP, HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and MIB to integrate into existing DCIM systems. Email alerts can be sent via SMTP, and user management supports LDAP(S), Radius, and Active Directory. Connection to Syslog servers is also possible (up to 2 servers).

Mounting and Installation

Mounting is tool-free in Zero-U-Space of Rittal VX IT or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. The delivery includes mounting hardware. The supply cable is 3 m long and fitted with a CEE plug (16 A/32 A). The PDU is designed for single-phase (1~) input supply.

Operational Advantages

The PDU enables precise energy measurement and monitoring per output socket, increasing the efficiency and safety of IT infrastructure. Programmable switching functions, such as sequential power-on after voltage recovery, prevent inrush currents. Relay states are retained during power failure, and bistable relays ensure low power consumption and high switching capacity, even with high inrush currents up to 300 A. The integrated emergency power supply for the web server via PoE ensures availability of control functions even during power failure. The PDU is suitable for environments requiring high reliability and safety.

Standards and Regulations

The PDU complies with the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU. It is certified according to standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. Measurement accuracy meets EN 62053-21. The PDU is designed for IT infrastructures with high requirements for safety, reliability, and energy efficiency.

Options

Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, including status monitoring. Differential current measurement (Type B) is possible per input, phase, or fuse. Monitoring of the optional surge protection device is also integrated. Connection of CMC III CAN-Bus sensors for environmental monitoring is possible, with up to 16 sensors connectable. Other enclosure colours are also available.

Accessories

Compatible accessories include CMC III CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), connection cables, covers for C13 and C19 sockets, mounting adapters, a universal lock for C14/C20 plugs, an RCM measurement module, a numeric code lock, a VX IT CMC III transponder reader, a Type 3 surge protection module, and a CMC III Online comfort handle VX with master key function.

Storage

The PDU can be stored at temperatures from -20 °C to 70 °C.

Materials

The enclosure is made of aluminium profile, black anodized, and the sockets are made of plastic.

Interfaces

The PDU features a USB 2.0 interface (USB-A), a CAN-Bus interface (RJ45), a serial interface RS232 (RJ12), and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Connection to external systems is via protocols such as HTTP, HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and MIB.

Energy Efficiency

The device is designed for low self-consumption and includes an energy-saving mode. The integrated power supply is redundant and ensures high availability.

Connection Type

The electrical connection type is CEE with a supply cable length of 3 m.

Input Supply

The PDU has a single-phase (1~) input supply.

Weight

The net weight is 4.8 kg, and the gross weight is 5.04 kg.

Customs Tariff Number

The customs tariff number is 85366990.

EAN

The EAN number is 4028177948129.

Manufacturer Number

The manufacturer number is 7979415.

Manufacturer

The manufacturer is Rittal.

Type

The type is DK 7979415.

Category

The category is 48,3 cm ( 19 inch )-Technik › Zubehör › Energiemanagement.

Suitable For

The PDU is suitable for enclosure types VX IT cabinet frame (≥ 1,800 mm) and 48,3 cm ( 19 inch ) profile rails (≥ 1,800 mm).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1910665
qrcode für Rittal 7979415 PDU Managed 16A/1P CEE 24xC13 4xC19