| General |
| Model | PDU, switched |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.740 mm |
| Number of sockets and type | 24 x C13 / 6 x C19 |
| Socket outlets | 24 x C 13, 6 x C 19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Number of RJ45 ports for sensor units max | 6 |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Cabinet type: VX IT cabinet frame: ≥ 2,000 mm, Cabinet type: VX IT 19"-profile rails: ≥ 2,000 mm |
The Rittal DK 7979337 is a
switched PDU (Power Distribution Unit) for use in IT network and server racks. It serves as an intelligent power distribution unit with integrated energy measurement per phase and enables individual switching control of the output sockets. The PDU is designed for use in racks with a minimum length of 2,000 mm, particularly for VX IT cabinet frames and 48,3 cm ( 19 inch )-profile rails. The compact design with dimensions 44 mm (width) × 1,740 mm (length) × 70 mm (depth) allows vertical mounting in Zero-U-Space, with tool-free installation. The housing is made of
aluminum profile, black anodized, while the sockets are made of
plastic.
Applications
The PDU is designed for use in professional IT infrastructures, particularly in data centers, server rooms, and network racks. It is suitable for central power distribution and monitoring for IT systems where precise energy measurement, load control, and remote monitoring are required. The integrated energy measurement per phase allows detailed analysis of energy consumption, enabling operational optimizations. The PDU is rated for a nominal operating voltage of 400 V (AC) and supports a nominal current of up to 32 A and a nominal power of 22 kW.
Functions and Equipment in Detail
The PDU features 24 sockets of type
C13 and 6 sockets of type
C19, each individually switchable. The switching function is performed via bistable relays, which enable low power consumption and high switching capacity, even with high inrush currents up to 300 A. The sockets are color-coded (L1=pink, L2=black, L3=white) to visually distinguish phases and fuse circuits. The PDU is self-powered and requires no external power supply. The measurement accuracy is ±1 % (kWh) according to standard
EN 62053-21.
Technology Explained Simply
The PDU is equipped with an integrated, fully redundant power supply unit fed from all phases, ensuring fault-tolerant power supply. Control is handled by an integrated CPU (ARM Cortex A8), which supports various functions such as programmable power-on behavior after voltage recovery (on/off/last status), programmable switching behavior (time/programmable logic), and operating hour counters (total and cyclic, resettable). A bright TFT display (128x128 pixels, RGB) with backlighting shows performance data and basic configuration. The display unit is rotatable by 180° and replaceable. Multicolored LEDs (green/yellow/red) indicate switching states and warning/alarm thresholds per phase or input. An integrated electromagnetic buzzer enables acoustic alarm signaling.
Compatibility and Accessories
The PDU is designed for use with Rittal VX IT cabinet frames and 48,3 cm ( 19 inch )-profile rails with a minimum length of 2,000 mm. The supply cable has a length of 3 m and is fitted with a
CEE connector type. The PDU supports connection to environmental sensors via a CAN-Bus interface (RJ45), allowing up to 16 sensors to be connected. Additional interfaces include USB 2.0 (USB-A), RS232 (RJ12), and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Communication occurs via protocols such as HTTP, HTTPS, SSH, Telnet, SNMP v1/v2c/v3, Modbus/TCP, OPC-UA, and FTP/SFTP. The PDU can be integrated into DCIM software, with MIBs available for integration. Connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is possible. Email alerts on alarm (SMTP) and use of custom certificates/TLS 1.2 are also supported.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the
mounting hardware. The PDU is designed for vertical mounting and can be installed in racks with a minimum length of 2,000 mm. The supply cable (3 m) allows flexible positioning of the power input.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated fault detection. Energy measurement per phase enables precise load distribution and monitoring. Individual switching control of sockets allows targeted load management and load avoidance. Remote control via network and protocol standards (such as SNMP, Modbus/TCP, OPC-UA) enables integration into existing monitoring systems. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures time accuracy even during power failure. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.