| General |
| Model | PDU, switched |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 845 mm |
| Number of sockets and type | 12 x C13 / 1 x C19 |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,200 mm |
The Rittal DK 7979310 is a
switched PDU (Power Distribution Unit) for use in IT network and server racks. It serves intelligent power distribution and monitoring in 19-inch systems, particularly in Rittal VX IT and TS IT racks with a minimum length of 1,200 mm. The PDU features a compact design with dimensions of 44 mm (width) × 845 mm (length) × 70 mm (depth) and enables tool-free mounting in Zero-U-Space. The housing is made of
black anodized aluminum profile, and the socket outlets are made of
plastic. Power supply is via a
CEE power cord with a length of 3 m, designed for single-phase input. The rated operating voltage is 230 V (AC), the maximum rated current is 16 A, corresponding to a rated power of 3.7 kW.
Applications
The PDU is designed for use in professional IT infrastructures where precise energy distribution, measurement, and control are required. It is particularly suitable for data centers, server rooms, and network racks where central monitoring of power consumers and targeted switching control are necessary. The integrated energy measurement per phase enables detailed analysis of energy consumption, allowing for operational optimizations. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing).
Functions and Equipment in Detail
The DK 7979310 features 12 socket outlets of type
C13 and one socket outlet of type
C19, all individually switchable. The switching function is performed by
bistable relays, which have low power consumption and can handle higher inrush currents up to 300 A. The relay states are retained even during power failure. The PDU offers
programmable switching behavior, which can be based on time schedules or logical conditions. After power restoration, the switching behavior (on, off, last status) can be individually configured. An integrated
electromagnetic buzzer provides acoustic alarm signaling for warnings or alarm situations.
Technology Explained Simply
The PDU is equipped with an
integrated, fully redundant power supply unit that can be powered from all phases, ensuring fault-tolerant power supply. Measurement accuracy is ±1 % (kWh) according to the standard
EN 62053-21. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. An
integrated real-time clock with battery backup (up to 10 years, replaceable) ensures accurate timestamping of measurement data. A bright
TFT display (128x128 pixels, RGB) with backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable. Multicolored LEDs (green/yellow/red) indicate switching status and warning or alarm thresholds per phase or input.
Compatibility and Accessories
The PDU is designed for use with Rittal VX IT and TS IT racks. Color-coded phase marking (L1=pink, L2=black, L3=white) facilitates assignment. Optionally,
CMC III CAN-Bus sensors can be connected to monitor environmental parameters such as temperature or humidity. Up to 16 sensors can be connected. The PDU supports connection of
surge protection modules Type 3 and offers the option for
residual current measurement (Type B) per input, phase, or fuse. Additionally,
mounting adapters and
covers for C13 and C19 sockets are available to optimize installation and safety.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT and TS IT racks. The delivery includes the
fastening material. The PDU is self-powered; no external power supply is required. The power cord (CEE, 3 m) allows flexible positioning. The PDU can also be installed in other enclosures with sufficient space, provided mounting conditions are met.
Operational Advantages
The DK 7979310 offers high operational reliability through redundant power supply and integrated fault detection. Detailed energy measurement per phase enables precise consumption analysis and optimization. Individual control of outputs reduces overload peaks through sequential switching after power restoration. The integrated network interface and support for various protocols (e.g., SNMP, Modbus/TCP, OPC-UA) enable integration into DCIM systems and remote monitoring. User management with rights management, LDAP(S)/Radius/Active Directory integration, and TLS 1.2 security ensure secure and controlled use. An operating hour counter (total and cyclic, resettable) supports maintenance planning.
Interfaces and Protocols
The PDU features a
fully redundant Ethernet interface (10/100/1000 Mbit/s), a
USB 2.0 interface (USB-A) for mass configuration, firmware updates, and data logging, a
CAN-Bus interface (RJ45) for environmental sensors, and a
serial interface RS232 (RJ12) for LTE unit, scripting, CLI, and use of custom certificates. Communication occurs via protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP. The PDU supports connection to Syslog servers (up to 2 servers) and enables email alerts in case of alarm (SMTP). Integration into 3rd-party DCIM software is possible via MIBs.
Standards and Regulations
The PDU complies with the
EMC Directive 2014/30/EU and the
Low Voltage Directive 2014/35/EU. Standards
EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 are met. Measurement accuracy corresponds to
EN 62053-21 with ±1 % (kWh). The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C.
Storage Temperature Range
The PDU can be stored at temperatures from -20 °C to 70 °C without affecting functionality.
Additional Functions
A digital input (potential-free contact) and an additional alarm output/relay output (changeover contact) extend application possibilities. The PDU can be emergency-powered via PoE (Power over Ethernet), ensuring the web server remains accessible even during power failure. Sequential shutdown of outputs protects connected devices during power failure.
Delivery Contents
The delivery includes the PDU and the
fastening material for mounting.