| General |
| Model | 19" version |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware, without connection cable, must be provided by customer |
| Options | Surge protection Type 3 with replaceable diverters during operation, with status monitoring, integrable into PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional surge protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors |
| Height | 44 mm |
| Depth | 144 mm |
| Length | 450 mm |
| Number of sockets and type | 6 x C13 |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Phases per input: 1~ |
| Electrical connection type | IEC C20 |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 800 mm, Housing type: VX IT 19"-profile rails: ≥ 800 mm |
The Rittal DK 7979302 is a
48,3 cm ( 19 inch ) power distribution unit (PDU) for IT network and server racks, serving as a
switched PDU with integrated energy metering and individual switching function for each output. The device is housed in a compact aluminium profile enclosure with a black anodized surface and features six C13 outlets. The rated operating voltage is 230 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 3.7 kW. Power input is via an IEC C20 connector, allowing the PDU to be directly connected to a network cabinet power supply. The power distribution unit is designed for use in racks with VX IT cabinet frames or 48,3 cm ( 19 inch ) profile rails with a minimum height of 800 mm. When mounted vertically, the unit can be installed tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks.
Applications
The PDU is designed for use in professional IT infrastructures, particularly in data centres, server rooms and network racks, where precise power distribution, energy metering and remote control are required. The integrated energy metering per phase enables detailed monitoring of energy consumption, allowing for optimisation of energy efficiency and load distribution. The individual switching function of the outputs supports control of IT systems, for example for sequential power-up after voltage recovery, to avoid inrush current peaks. The PDU is also suitable for integration into DCIM systems, as it supports various protocols such as SNMP, Modbus/TCP and OPC-UA.
Functions and Equipment in Detail
The PDU features an integrated, fully redundant power supply that can be powered from all phases, ensuring fault-tolerant operation. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. Fuse monitoring is available for PDUs with integrated fuses. The PDU is equipped with a bright TFT display (128x128 pixels, RGB, backlit) showing performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring correct display regardless of mounting position. Multicolour LEDs (green/yellow/red) indicate switching states and warning or alarm thresholds per phase or input. An integrated electromagnetic buzzer enables acoustic alarm signalling.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) that processes measurement data and controls switching functions. Switching is performed via bistable relays, enabling low power consumption and high switching capacity, even with high inrush currents up to 300 A. Relay states are retained even during power failure. The PDU includes an integrated real-time clock with battery backup (up to 10 years, replaceable battery) for time control and logging. Switching behaviour is programmable, for example for time- or logic-based control. The power-up behaviour after voltage recovery can be programmed to on", "off", or "last state. An operating hour counter (total and cyclic, resettable) enables documentation of operating time.
Compatibility and Accessories
The PDU is equipped with a range of interfaces enabling flexible integration into existing systems. Via a fully redundant Ethernet interface (10/100/1000 Mbit/s), the PDU can be integrated into a network. Interfaces also include a USB 2.0 port (USB-A) for mass configuration, firmware updates and data recording, a CAN-Bus interface (RJ45) for connecting up to 16 CMC III CAN-Bus sensors for environmental monitoring, and a serial interface RS232 (RJ12) for LTE unit, scripting and CLI. The PDU supports protocols such as Web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, as well as FTP/SFTP for updates and file transfers. User management includes rights management, LDAP(S)/Radius/Active Directory integration and Syslog server integration (up to 2 servers). E-mail alerts on alarm (SMTP) are also possible. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, with its status monitored. Differential current measurement (Type B) per input, phase or fuse is also available. Colour coding of phases (L1=pink, L2=black, L3=white) facilitates identification.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes mounting hardware. The PDU is self-powered and does not require external power supply. Mounting is on 48,3 cm ( 19 inch ) profile rails with a minimum height of 800 mm.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated fault detection. Precise energy metering enables transparent cost and energy consumption control. Remote control and monitoring via network and protocol standards facilitate integration into existing management systems. The individual switching function of the outputs supports IT system control and prevents inrush current peaks. The integrated real-time clock and operating hour counter enable detailed documentation of operational behaviour. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity from 10 % to 95 % (non-condensing). Storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21.