| General |
| Model | PDU, metered, Incl. RCM |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | surge protection Type 3 with replaceable discharge devices during operation, with status monitoring, integrable into PDU housing, monitoring of optional surge protection, CMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | Differential current measurement (Type B) per supply/phase/fuse, energy measurement per phase or supply, powerful CPU (ARM Cortex A8), digital input (voltage-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.695 mm |
| Number of sockets and type | 24 x C13 / 6 x C19 |
| Rated operating voltage | 400 V AC |
| Rated current (max.) | 16 A |
| Nominal power | 11 kW |
| Power supplies | Phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
The Rittal DK 7979276 is a
metered PDU (Power Distribution Unit) for use in IT network and server racks. It serves for power distribution and monitoring in 19-inch enclosures and features integrated energy measurement per phase as well as differential current measurement (RCM / Type B). The unit is designed for a rated operating voltage of 400 V AC and supports a nominal current of up to 16 A at a nominal power of 11 kW. Power supply is via a CEE connection cable with a length of 3 m. The PDU is self-powered and does not require external power supply. Dimensions are 44 mm (width) × 1,695 mm (length) × 70 mm (depth), with the unit being tool-free installable in the Zero-U-Space of Rittal VX IT or TS IT racks. The housing consists of a black anodized aluminium profile, the socket outlets are made of plastic. The socket configuration includes 24 x C13 and 6 x C19 outlets. Phases and fuse circuits are colour-coded (L1=pink, L2=black, L3=white) to enable clear identification.
Applications
The PDU is designed for use in IT infrastructures, particularly in server and network racks, where precise energy measurement and monitoring are required. It is suitable for racks with a minimum length of 1,800 mm, both with VX IT cabinet frames and 19-inch profile rails. The integrated differential current measurement enables detection of fault currents, which is important for the safety of electrical installations. Phase-based energy measurement allows detailed analysis of power demand for individual racks or server groups.
Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and an integrated real-time clock with battery backup (up to 10 years, replaceable). Measurement accuracy is ±1 % (kWh) according to EN 62 053-21. Display is via a bright TFT screen with 128x128 pixels (RGB) and backlighting, which is rotatable by 180° and replaceable. The PDU offers operating hour counters (total and cyclic, resettable), adjustable limits for voltage, current and power, and an integrated electromagnetic buzzer for acoustic alarm. Fuse monitoring is possible with PDUs featuring integrated fuses (16 A, Carling type). The PDU’s power supply is fault-tolerant and redundant, distributed across all phases.
Technology Explained Simply
The PDU measures power consumption per phase, capturing active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Differential current measurement (Type B) is performed per input, phase or fuse, enabling precise fault current detection. The integrated CPU enables powerful data processing and management. The PDU is designed for operation in a temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing). Storage temperature is -20 °C to 70 °C.
Compatibility and Accessories
The PDU is equipped with a fully redundant Ethernet interface (10/100/1000 Mbit/s) and supports protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP. Integration into DCIM software is possible via MIB. The CAN-Bus interface (RJ45) allows connection of up to 16 CMC III environmental sensors. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation and status monitoring can be integrated. Suitable accessories include CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 outlets, mounting adapters, a universal lock for C14/C20 plugs, a numeric code lock for CMC III, a VX IT CMC III transponder reader (RAL 9005), a PDU surge protection device (article number 7979723), and a CMC III online comfort handle VX with master key function.
t
Installation and Mounting
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes mounting hardware. The PDU is designed for vertical mounting, with the display unit rotatable by 180° to ensure correct display regardless of mounting position. The connection cable (CEE, 3 m) allows flexible positioning of the power input.
Operational Advantages
The PDU offers high measurement accuracy, comprehensive network interface, and flexible configuration via various protocols. The integrated real-time clock and operating hour counter enable precise documentation and analysis of operational behaviour. Redundant power supply increases reliability. Support for environmental sensors via CAN-Bus extends monitoring capabilities. The PDU is designed for use in IT environments with high requirements for safety, reliability, and energy efficiency. The use of TLS 1.2, LDAP(S), Radius, Active Directory, and Syslog server integration enables secure and integrated network management. E-mail alerting (SMTP) and user management with rights management support professional operations. The power-saving design and low self-consumption contribute to energy efficiency. The PDU is certified according to EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21, and complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU.