Rittal 7979246, EAN: 4069196015164

Rittal 7979246 DK PDU metered 16A 3-phase 18xC13+12xCombi

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979246 DK PDU metered 16A 3-phase 18xC13+12xCombi

Lieske Part No. 894309
Mfg Part No 7979246
EAN-Code 4069196015164
Manufacturer Rittal
Here only 859,40 EUR
1.022,69 EUR incl. VAT

Further information for Rittal 7979246 DK PDU metered 16A 3-phase 18xC13+12xCombi

General
ModelPDU, metered
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Description of measurement functionsmeasurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Width44 mm
Depth70 mm
Length1.695 mm
Number of sockets and type18 x C13 / 12x Combi (C13/C19)
Rated operating voltage400 V (AC)
Rated current (max.)16 A
Nominal power11 kW
Power suppliesNumber: 1, phases per input: 3~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm
The Rittal DK 7979246 is a PDU (Power Distribution Unit) with energy measurement, specifically designed for use in IT network and server racks. As a metered PDU, it provides detailed power distribution and monitoring, with measurement per phase or at the input. The device is housed in a compact aluminium profile with a black anodized surface and has an overall length of 1,695 mm, a width of 44 mm, and a depth of 70 mm. Power distribution is via 18 C13 sockets and 12 Combi-sockets (C13/C19), with a rated operating voltage of 400 V (AC). The maximum rated current is 16 A, corresponding to a rated power of 11 kW. Power input is via a 3-phase supply cable with a length of 3 m and CEE connector type.

Applications

The PDU is designed for use in IT infrastructures, particularly in Rittal VX IT racks with a cabinet frame or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. Vertical mounting is tool-free in Zero-U-Space, allowing seamless integration into existing rack systems. The phase colour coding (L1=pink, L2=black, L3=white) simplifies assignment and maintenance. The PDU is self-powered and does not require external power supply, simplifying installation.

Functions and Equipment in Detail

The PDU features an integrated real-time clock with battery backup (up to 10 years, replaceable), ensuring time continuity even during power failure. An integrated electromagnetic buzzer enables acoustic alarm in critical conditions. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. Display is via a bright TFT screen with 128x128 pixels (RGB) and backlight, which is rotatable by 180° and replaceable. Additionally, a power LED indicates voltage status. The PDU measures voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current for unbalanced load detection. An operating hour counter (total and cyclic, resettable) enables usage documentation.

Technology Explained Simply

The PDU is equipped with a powerful CPU (ARM Cortex A8) handling measurement and control functions. Power supply is redundant across all phases, ensuring fault-tolerant operation. The integrated, fully redundant power supply ensures high availability. The PDU allows setting of thresholds for voltage, current, and power to trigger warnings or alarms. A digital input (potential-free contact) and an additional alarm output (relay output, changeover) enable integration into existing alarm systems.

Compatibility and Accessories

The PDU supports connection of CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Optionally, a Type 3 surge protection with replaceable discharge elements during operation and status monitoring can be integrated. Differential current measurement (Type B) is available per input, phase, or fuse. The PDU is equipped with a fully redundant Ethernet interface (10/100/1000 Mbit/s) for communication with network and management systems. Additional interfaces include USB 2.0 (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for environment sensors, and a serial interface RS232 (RJ12) for LTE unit, scripting, and CLI. Communication uses protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB, and FTP/SFTP. User management includes rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server integration (up to 2 servers). E-mail notification on alarm (SMTP) is also possible.

Mounting and Installation

Mounting is tool-free in Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes fastening material. The PDU is designed for use in racks with a minimum length of 1,800 mm. The supply cable has a length of 3 m and is fitted with a CEE plug.

Operational Advantages

The PDU offers high operational reliability through redundant power supply and integrated alarm functions. Phase-specific energy measurement enables precise load distribution and monitoring. The integrated network interface and support for multiple protocols facilitate integration into DCIM systems. The low power consumption and energy-saving design reduce the device’s own energy usage. The ability to connect environment sensors extends monitoring capabilities to temperature, humidity, and other parameters. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity from 10 % to 95 % (non-condensing). Storage temperature is from -20 °C to 70 °C. The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/894309
qrcode für Rittal 7979246 DK PDU metered 16A 3-phase 18xC13+12xCombi