Rittal 7979245, EAN: 4069196015157

Rittal 7979245 DK PDU metered 32A 3-phase 18xC13+12xCombi

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979245 DK PDU metered 32A 3-phase 18xC13+12xCombi

Lieske Part No. 894308
Mfg Part No 7979245
EAN-Code 4069196015157
Manufacturer Rittal
Here only 1.023,96 EUR
1.218,51 EUR incl. VAT

Further information for Rittal 7979245 DK PDU metered 32A 3-phase 18xC13+12xCombi

General
ModelPDU, metered
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Description of measurement functionsmeasurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Width44 mm
Depth70 mm
Length1.895 mm
Number of sockets and type18 x C13 / 12x Combi (C13/C19)
Rated operating voltage400 V (AC)
Rated current (max.)32 A
Nominal power22 kW
Power suppliesNumber: 1, phases per input: 3~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forCabinet type: VX IT cabinet frame: ≥ 2,000 mm, cabinet type: VX IT 19"-profile rails: ≥ 2,200 mm
The Rittal DK 7979245 is a PDU (Power Distribution Unit) with energy metering in metered configuration, specifically designed for use in IT network and server racks. The device features a compact design with a length of 1,895 mm, a width of 44 mm, and a depth of 70 mm, making it ideal for integration into racks with a minimum frame size of 2,000 mm (VX IT cabinet frame) or 2,200 mm (VX IT 48,3 cm ( 19 inch ) profile rails). The power distribution is designed for a rated operating voltage of 400 V (AC) and supports a rated current of up to 32 A as well as a rated power of 22 kW. Power input is via a CEE supply cable with a length of 3 m. The PDU is equipped with an integrated, fully redundant power supply unit that is powered from all phases, ensuring fault-tolerant power supply. The PDU powers itself; no external power supply is required.

Applications

The DK 7979245 is designed for use in IT infrastructures, particularly in server and network racks, where precise energy distribution and monitoring are required. Tool-free vertical mounting in the Zero-U-Space of Rittal VX IT or TS IT racks simplifies installation. The PDU is suitable for environments requiring detailed energy balancing, load monitoring, and alarm notification when deviations from preset thresholds occur. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures accurate timestamping of measurements and events.

Functions and Equipment in Detail

The PDU features 18 C13 outlets and 12 Combi outlets (C13/C19) made of plastic. The outlets are color-coded (L1=pink, L2=black, L3=white) to visually distinguish phases and fuse circuits. Metering functions are performed per phase or per input, with a measurement accuracy of ±1 % (kWh) according to EN 62053-21. Measured values include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. Fuse monitoring is also integrated. The PDU is equipped with a bright TFT display (128x128 pixels, RGB) with backlighting and an energy-saving mode, displaying performance data and basic configuration. The display is rotatable 180° within the housing and replaceable. An integrated electromagnetic buzzer enables acoustic alarm notification. Operating hour counters for total and cyclic operating hours are resettable. The PDU has an operating temperature range of 5 °C to 50 °C and can be operated at a humidity level of 10 to 95 % (non-condensing).

Technology Explained Simply

The PDU is equipped with a powerful CPU (ARM Cortex A8) that handles data processing, network communication, and interface control. The fully redundant Ethernet interface (10/100/1000 Mbit/s) enables a stable network connection. The PDU supports TCP/IP v4 and v6, DHCP, DNS, NTP, SSH, Telnet, SNMP v1, v2c and v3, Modbus/TCP, OPC-UA, and FTP/SFTP for firmware updates and file transfers. A USB 2.0 port (USB-A) is provided for mass configuration, firmware updates, and data logging. Via a CAN-Bus interface (RJ45), up to 16 CMC III environmental sensors can be connected to monitor temperature, humidity, or other environmental parameters. A serial interface RS232 (RJ12) is intended for connecting an LTE unit, scripting, CLI, and using custom certificates (TLS 1.2). The PDU supports email alerts on alarm (SMTP), user management with rights management, integration with LDAP(S), Radius, or Active Directory, and connection to Syslog servers (up to 2 servers). The PDU also includes a digital input (potential-free contact) and an additional alarm output/relay output (changeover contact).

Compatibility and Accessories

The DK 7979245 is designed for use in Rittal VX IT racks. Compatible accessories include CMC III CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), connection cables, covers for C13 and C19 outlets, mounting adapters for TE 8000, PDU universal locking for C14/C20 plugs, numeric code lock for CMC III, VX IT CMC III transponder reader (RAL 9005), and the CMC III online comfort handle VX with master key function. The PDU can optionally be equipped with a surge protection device Type 3, which supports replaceable discharge devices during operation and status monitoring. Differential current measurement (Type B) per input, phase, or fuse is also possible. Monitoring of the optional surge protection is integrated. Other housing colors are available as optional.

Mounting and Installation

Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes fastening material. The PDU is designed for vertical mounting and can be installed in racks with sufficient space (minimum 2,000 mm cabinet frame or 2,200 mm profile rails). The integrated real-time clock with battery backup ensures correct timestamping even during power failure. The display unit is rotatable and can be adjusted according to the mounting position.

Operational Advantages

The DK 7979245 offers precise energy monitoring with high measurement accuracy (±1 % according to EN 62053-21) and enables detailed analysis of energy consumption per phase. The integrated network communication and support for various protocols (SNMP, Modbus/TCP, OPC-UA) facilitate integration into existing DCIM systems. The fully redundant power supply and fault-tolerant architecture increase reliability. Tool-free mounting and integrated alarm notification (acoustic and via email) improve maintainability and responsiveness during operation. The PDU is designed for use in IT environments with high requirements for energy efficiency and operational safety. The operating temperature range of 5 °C to 50 °C and high humidity resistance (10–95 %, non-condensing) enable flexible deployment in various rack systems.

Standards and Regulations

The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Standards include EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. The PDU is conformally certified for use in IT infrastructures and meets requirements for safety, EMC compatibility, and measurement accuracy.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/894308
qrcode für Rittal 7979245 DK PDU metered 32A 3-phase 18xC13+12xCombi