| General |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.740 mm |
| Number of sockets and type | 24 x C13 / 6 x C19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Number of RJ45 ports for sensor units max | 6 |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Cabinet type: VX IT cabinet frame: ≥ 2,000 mm, Cabinet type: VX IT 19"-profile rails: ≥ 2,000 mm |
The Rittal DK 7979237 is a
PDU (Power Distribution Unit) with integrated
energy measurement per phase, specifically designed for use in IT network and server racks. As a
metered PDU, it enables precise monitoring of power consumption, power, voltage, frequency, and other electrical parameters. The unit is housed in a compact aluminium profile with a black anodized surface and has an overall length of 1,740 mm, a width of 44 mm, and a depth of 70 mm. Power distribution is provided via 24 C13 outlets and 6 C19 outlets, with the socket outlets made of plastic. The rated operating voltage is 400 V (AC), the maximum rated current is 32 A, corresponding to a rated power of 22 kW. Power input is via a CEE cable with a length of 3 m. The PDU is designed for use in Rittal VX IT rack frames with a minimum length of 2,000 mm, as well as in VX IT 48,3 cm ( 19 inch ) profile rails with a minimum length of 2,000 mm. For vertical mounting, it can be installed tool-free in Zero-U-Space, with a tool-free mounting kit available for VX IT. The delivery includes mounting hardware.
Applications
The PDU is designed for use in IT infrastructures, server rooms, and data centres where precise energy monitoring and control are required. It is particularly suitable for racks where detailed load distribution and measurement per phase are necessary to optimize power supply efficiency and avoid overloads. The integrated energy measurement allows monitoring of the total power consumption of an entire IT rack, enabling precise load planning and control. The phase colour coding (L1=pink, L2=black, L3=white) supports identification and assignment of circuits.
Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and an integrated real-time clock with battery backup, which lasts up to 10 years and is replaceable. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for imbalance detection. An operating hour counter records total and cyclic operating time and is resettable. The PDU is self-powered and does not require external power supply. An integrated electromagnetic buzzer provides acoustic alarm. Adjustable thresholds for voltage, current, and power allow individual configuration of warning and alarm limits. The PDU features a bright TFT display with 128x128 pixels (RGB), backlighting, and an energy-saving mode, displaying performance data and basic configuration. The display unit is rotatable 180° within the housing and replaceable. Position sensors ensure correct display orientation on the web interface.
Technology Explained Simply
The PDU is powered redundantly from all phases, ensuring fault-tolerant and reliable operation. The integrated power supply is fully redundant and draws power from all phases, ensuring high availability even in case of phase faults or failures. The PDU includes compact circuit breakers (16 A, Carling type) for protecting individual circuits. Measurement is performed per phase or per input, enabling detailed energy consumption analysis. The PDU is designed for operation in a temperature range of 5 °C to 50 °C and humidity of 10 to 95 % (non-condensing). Storage temperature ranges from -20 °C to 70 °C.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces enabling flexible integration into existing systems. These include a fully redundant Ethernet interface (10/100/1000 Mbit/s), a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for up to 16 environment sensors of type CMC III, and a serial interface RS232 (RJ12) for LTE unit, scripting, and CLI. The PDU supports protocols such as web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, and FTP/SFTP for updates and file transfers. User management includes rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server connection (up to 2 servers). Email alerts on alarm (SMTP) are also possible. The PDU can be optionally equipped with surge protection modules Type 3, featuring replaceable discharge units during operation and status monitoring. Differential current measurement (Type B) per input, phase, or fuse is also possible. Monitoring of optional surge protection is integrated. Connection of up to 16 CMC III CAN-Bus sensors for environmental monitoring is possible. Other housing colours are available as optional.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The PDU is designed for vertical mounting and can be installed without tools. The delivery includes required mounting hardware. The input cable has a length of 3 m and is fitted with a CEE plug. The unit is designed for use in rack frames with a minimum length of 2,000 mm.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated protection elements. Precise energy measurement enables efficient load distribution and control. The integrated real-time clock and operating hour counter support maintenance planning. The wide range of interfaces and protocols allows flexible integration into existing IT infrastructures and DCIM systems. The energy-efficient design and low self-consumption reduce the PDU’s own energy usage. Acoustic alarm via the integrated buzzer and adjustable thresholds enhance operational safety. The ability to connect CMC III sensors extends monitoring functions to include environmental parameters such as temperature and humidity.
Standards and Regulations
The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21 are met. Measurement accuracy conforms to EN 62053-21 with an accuracy of ±1 % (kWh).