Rittal 7979213, EAN: 4028177947665

Rittal 7979213 PDU metered 12x C13 4x C19

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979213 PDU metered 12x C13 4x C19

Lieske Part No. 593692
Mfg Part No 7979213
EAN-Code 4028177947665
Manufacturer Rittal
Here only 726,36 EUR
864,37 EUR incl. VAT

Further information for Rittal 7979213 PDU metered 12x C13 4x C19

General
ModelPDU, metered
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Description of measurement functionsmeasurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Width44 mm
Depth70 mm
Length1.095 mm
Number of sockets and type12 x C13 / 4 x C19
Rated operating voltage230 V (AC)
Rated current (max.)32 A
Nominal power7,4 kW
Power suppliesNumber: 1, Phases per input: 1~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
Number of RJ45 ports for sensor units max2
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm
The Rittal DK 7979213 is a PDU (Power Distribution Unit) with integrated energy measurement per phase, specifically designed for use in IT network and server racks. As a metered PDU, it enables precise monitoring of power consumption per phase or total input, thereby improving energy efficiency and operational monitoring in data centers and IT infrastructures. The device is housed in a compact aluminum profile with a black anodized surface and has an overall length of 1,095 mm, a width of 44 mm, and a depth of 70 mm. Power distribution is provided via 12 C13 outlets and 4 C19 outlets, with a rated operating voltage of 230 V (AC) and a maximum rated current of 32 A. The rated power is 7.4 kW, enabling the supply of multiple IT systems.

Applications
The PDU is designed for use in racks of the VX IT type, particularly in cabinet frames with a width of 1,200 mm or more, or on 48,3 cm ( 19 inch ) profile rails with a length of 1,800 mm or more. When mounted vertically, it can be installed tool-free in the Zero-U-Space of the rack, minimizing space requirements. The color-coded phase marking (L1=pink, L2=black, L3=white) supports clear identification and simplifies maintenance. The PDU is self-powered and does not require an external power supply, simplifying installation.

Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and enables measurement of voltage, current, frequency, active power, active energy, apparent power, reactive energy, power factor (cosPhi), phase angle, and neutral conductor current. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. A bright TFT display with 128x128 pixels (RGB) and backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable, enabling operation even when mounted vertically. An integrated electromagnetic buzzer provides acoustic alarm signaling for exceedances. Configurable thresholds for voltage, current, and power can be set for warnings and alarms. An operating hour counter records total and cyclic operating time and is resettable.

Technology Explained Simply
The PDU is powered via an integrated, fully redundant power supply unit that can be fed from all phases, ensuring fault-tolerant and reliable power supply. The supply cable has a length of 3 m and is equipped with a CEE plug. The PDU is designed for operation in environments with temperatures from 5 °C to 50 °C and humidity from 10 % to 95 % (non-condensing). The storage temperature range is between -20 °C and 70 °C. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures accurate time display even during power failure.

Compatibility and Accessories
The PDU supports connection to CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Interfaces include a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for sensors, a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI, and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Additionally, there is a digital input (potential-free contact) and an additional alarm output/relay output (changeover contact). The PDU supports protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP. Integration into DCIM software is possible via MIB. Connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is also supported. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, equipped with status monitoring. Differential current measurement (Type B) per input, phase, or fuse is also possible.

Installation and Mounting
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the required mounting hardware. The PDU is designed for use in IT infrastructures that require high reliability, energy efficiency, and monitoring capabilities.

Operational Advantages
The PDU offers high measurement accuracy, comprehensive network integration, and flexible configuration. The integrated real-time clock, operating hour counter, and acoustic alarm support maintenance and monitoring. The energy-saving design with low self-consumption reduces energy expenditure. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA enables integration into existing monitoring and management systems. The PDU is suitable for use in data centers and IT infrastructures where precise energy consumption measurement and control are required.

Standards and Regulations
The PDU complies with the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU. Standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21 are met. Measurement accuracy conforms to EN 62053-21 with ±1 % (kWh). The PDU is designed for use in IT infrastructures with high requirements for safety and reliability.

Delivery Contents
Incl. mounting hardware

Accessories
Compatible accessories include CMC III CAN-Bus cables in various lengths (0.5 m, 1.0 m, 1.5 m), connection cables, covers for C13 and C19 outlets, mounting adapters, universal locking for C14/C20 plugs, numeric code lock, transponder reader, surge protection (7979722), and Online Comfort Handle VX with Master-Key function.