Rittal 7979202, EAN: 4028177947603

Rittal 7979202 PDU Metered 16A/1P IEC-C20 6xC13 19"

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979202 PDU Metered 16A/1P IEC-C20 6xC13 19"

Lieske Part No. 1980388
Mfg Part No 7979202
EAN-Code 4028177947603
Manufacturer Rittal
Here only 657,92 EUR
782,92 EUR incl. VAT

Further information for Rittal 7979202 PDU Metered 16A/1P IEC-C20 6xC13 19"

General
Model19" version
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware, without connection cable, must be provided by customer
OptionsCMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors
Description of measurement functionsmeasurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Height44 mm
Depth144 mm
Length450 mm
Number of sockets and type6 x C13
Rated operating voltage230 V (AC)
Rated current (max.)16 A
Nominal power3,7 kW
Power suppliesNumber: 1, Phases per input: 1~
Electrical connection typeIEC C20
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & datalogging, CAN-Bus interface (RJ45) for up to 16 environmental sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant monitoring via 2nd network, fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 800 mm, Housing type: VX IT 19"-profile rails: ≥ 800 mm
The Rittal DK 7979202 is a 48,3 cm ( 19 inch ) power distribution unit (PDU) with integrated energy measurement, specifically designed for use in IT network and server racks. It enables precise measurement of energy consumption per phase or at the input, and provides a comprehensive network interface for remote monitoring and control. The PDU is housed in a compact aluminium profile with a black anodized surface and features six C13 outlets for powering IT devices. The electrical connection is made via an IEC C20 plug, with a rated operating voltage of 230 V (AC) and a maximum rated current of 16 A, corresponding to a rated power of 3.7 kW.

Applications
The PDU is suitable for use in VX IT type racks, particularly in cabinet frames with a minimum depth of 800 mm or on 48,3 cm ( 19 inch ) profile rails with corresponding depth. When mounted vertically, it can be installed tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The phase colour coding (L1=pink, L2=black, L3=white) simplifies assignment and securing of circuits. The unit is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing).

Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) enabling measurement of voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. A bright TFT display with 128x128 pixels (RGB) and backlighting shows performance data and basic configuration. The display unit is rotatable by 180° and replaceable, ensuring correct orientation regardless of mounting position. An integrated electromagnetic buzzer provides acoustic alarm for exceeding set thresholds for voltage, current, or power. The operating hour counters are resettable both total and cyclically.

Technology Explained Simply
The PDU is self-powered via the mains, requiring no external power supply. The integrated, fully redundant power supply ensures fault-tolerant power delivery, redundantly supplying all phases. The integrated real-time clock is buffered by a replaceable battery with a lifespan of up to 10 years. The PDU is designed for IT infrastructures requiring high availability and transparency of energy consumption. Measurement per phase enables detailed analysis of energy consumption in individual circuits.

Compatibility and Accessories
The PDU is equipped with a variety of interfaces, including a USB 2.0 interface (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for connecting up to 16 CMC III CAN-Bus sensors for environmental monitoring, and a serial RS232 interface (RJ12) for LTE modules, scripting, and CLI. The network interface is fully redundant (10/100/1000 Mbit/s) and allows connection to two separate networks. The PDU supports protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP, and MIB for integration into DCIM software. User management with rights management, LDAP(S)/Radius/Active Directory integration, Syslog server connection (up to 2 servers), and email alerts on alarm (SMTP) are also integrated.

Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the necessary mounting hardware. The PDU is designed for use in racks with a minimum depth of 800 mm. Mounting is done on the 48,3 cm ( 19 inch ) profile rails, with the unit having a height of 44 mm, depth of 144 mm, and length of 450 mm.

Operational Advantages
The PDU offers high measurement accuracy, a comprehensive network interface, and flexible configuration. The integrated real-time clock and acoustic alarm ensure reliable monitoring. The fully redundant network interface and support for multiple protocols enable flexible integration into existing IT infrastructures. Tool-free mounting and compact design simplify installation and maintenance. The energy-efficient design with low self-consumption reduces the PDU's own energy demand.

The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. Storage is permitted in a temperature range of -20 °C to 70 °C.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1980388
qrcode für Rittal 7979202 PDU Metered 16A/1P IEC-C20 6xC13 19"