| General |
| Model | Wall surface mounted |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including pleated filter |
| Fan | Diagonal, split-pole motor |
| Airflow free blowing (with pleated filter) | At 50 Hz: 218 m³/h, At 60 Hz: 191 m³/h |
| Airflow with associated exhaust filter including pleated filter | At 50 Hz: 191 m³/h, At 60 Hz: 161 m³/h |
| Airflow free-blowing (with filter) | At 50 Hz: 175 m³/h, at 60 Hz: 157 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 130 m³/h, At 60 Hz: 112 m³/h |
| Rated operating voltage | 115 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 35.5 W, At 60 Hz: 38.2 W |
| Rated current max. | At 50 Hz: 0.41 A, At 60 Hz: 0.42 A |
| Width | 255 mm |
| Height | 255 mm |
| Depth | 129 mm |
| Built-in depth | 108 mm |
| Mounting cutout | Cutout width: 224 mm, cutout height: 224 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with nonwoven filter/pleated filter, IP 55 with pleated filter and absorber mat, IP 56 with nonwoven filter/pleated filter and spray water hood |
| NEMA degree of protection | Type 12 with felt filter/pleated filter, Type 3, 3R, 4, 4X with felt filter/pleated filter and spray water hood |
| Fuse | Circuit breaker/fuse: 4 A |
| Note | For the filter fan 3237.XXX, the electrical connection is made via 2 individual wires (approx. 300 mm length) on the device; for all other filter fans, via spring clamp terminal. |
| Operating temperature range | -30 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 48 dB(A), At 60 Hz: 45 dB(A) |
The Rittal SK 3240.710 is a
filter fan for
enclosure climate control, designed as a
wall-mounted unit. It serves for controlled ventilation of enclosures, regulating internal temperature and extending the service life of installed electronic components. The unit is delivered as a
fully ready-to-install assembly and includes a
pleated filter as standard, preventing dust and particles from entering the enclosure. The unit is made of
plastic and available in
RAL 7035, enabling visual harmonization with standard enclosure fronts.
Applications
The filter fan is designed for use in industrial environments where continuous ventilation is required to maintain operating temperature within permissible limits inside the enclosure. It is particularly suitable for installations in manufacturing, automation technology, or power supply applications, where enclosures are installed in areas with high dust levels or outdoors. The
protection rating IP 54 (with nonwoven/pleated filter) ensures protection against dust and splashing water, allowing the fan to operate in slightly damp or dusty environments. With additional components such as a
spray water hood, the protection rating can be increased to
IP 56, making it suitable for environments with heavy splashing water. The
NEMA Type 12 protection rating (with nonwoven/pleated filter) and options
Type 3, 3R, 4, 4X (with spray water hood) extend the application range in North American or international installations.
Functions and Equipment in Detail
The fan features
diagonal fan technology with a
split-pole motor, ensuring higher pressure stability and consistent airflow. The diagonal exhaust direction provides more even cooling of the enclosure, avoiding thermal hotspots. Airflow is
218 m³/h at 50 Hz and
191 m³/h at 60 Hz when using the included pleated filter. With a nonwoven filter, airflow reduces to
175 m³/h (50 Hz) or
157 m³/h (60 Hz). Airflow is further reduced when an outlet filter is installed:
191 m³/h (50 Hz) or
161 m³/h (60 Hz) with pleated filter, and
130 m³/h (50 Hz) or
112 m³/h (60 Hz) with nonwoven filter. The
rated power is
35.5 W at 50 Hz and
38.2 W at 60 Hz, with a
rated current of up to
0.41 A (50 Hz) or
0.42 A (60 Hz). The
rated operating voltage is
115 V, 1~, 50 Hz/60 Hz, enabling universal use in various power networks. The
sound pressure level is
48 dB(A) at 50 Hz and
45 dB(A) at 60 Hz, allowing for acoustically pleasant operation in workspaces.
Technology Explained Simply
The diagonal fan technology ensures that air flows diagonally, not vertically, out of the unit. This leads to more even air distribution within the enclosure and prevents hot air from accumulating in specific areas. The split-pole motor is a direct current motor known for its reliability and low maintenance requirements. The integrated
pleated filter technology provides high filtration performance in a compact design. The filter can be easily replaced via a new opening mechanism on the louver grid without requiring tools. Installation is tool-free using optimized snap hooks, enabling quick and secure mounting on the enclosure. The
installation depth is
108 mm, and the
mounting cutout has a width and height of
224 mm each.
Compatibility and Accessories
The filter fan can be combined with various accessories to extend protection and functionality. These include
outlet filters in RAL 7035, which affect airflow, and
spray water hoods made of stainless steel, which increase protection to IP 56. Additionally,
pleated filters and
nonwoven filters are available as replacements, with pleated filters included in the delivery. For precise temperature control,
thermostats or
digital temperature display and control units can be used. A
speed controller allows adjustable airflow, and
filter mat dispensers simplify filter replacement. A
blanking cover is also available to close mounting cutouts.
Installation and Mounting
Installation is tool-free on the enclosure front. The unit is inserted into the designated mounting cutout (224 mm x 224 mm) and secured using snap hooks. Electrical connection is made via
spring clamp terminals, providing a quick and secure connection. The unit is designed for an
operating temperature of -30 °C to 55 °C, with a
storage temperature of
-30 °C to 70 °C. The
fuse rating is specified as
4 A, ensuring protection against overload.
Operational Advantages
The Rittal SK 3240.710 offers a reliable and low-maintenance ventilation solution for enclosures. Tool-free installation and easy filter replacement reduce installation and maintenance time. High airflow at low sound pressure ensures efficient cooling without acoustic disturbance. The high protection rating and compatibility with various accessories make the fan flexible for use in different industrial environments. The inclusion of
pleated filters ensures high filtration performance from the start and prevents particles from entering the enclosure.